Using ESP
Terminal Tab
When Show Non-Printable Characters is checked, characters such as “CRLF” will be displayed in the Terminal window. When Enhanced Format is checked, the characters are displayed with more detailed formatting. Change Keyboard Macros In this dialog you can first select the function key and then enter your macro keystrokes in the associated key map. For example, to make Ctrl-F5 the keystroke to enable, send a trigger character, select F5, and then in the Ctrl row, enter <trigger character> and click OK. Then whenever the Ctrl-F5 keystroke is pressed, the trigger character will start the read cycle. Change Font Allows you to modify the font used for decode data received from the Imager on the Terminal screen. Change Echo Font Allows you to modify the font used for command characters typed into the Terminal view. Toolbar Style Displays user-selected toolbar buttons as icons, text only, or both (default).
FIS-6300 ESD Imager User’s Manual
2-7
Page 32
Menu Toolbar
Bar Code Options Tab
The Bar Code Options dialog allows you to set the size (in mils) of user-created symbols. Sizing Information Sets the bar width (in thousands of an inch) of user-created symbols. A bar width of 14 is 0.014 inches.
2-8
FIS-6300 ESD Imager User’s Manual
Page 33
Using ESP
Grade Report Options Tab
Overall Grade Based On Allows you to choose which symbol characteristics will be considered in generating a symbol quality grade. Use Number Grades Allows you to switch from the default letter grades to number grades in symbol quality report output. Show Report Options during ‘Generate Report’ Sets the symbol quality report output to show the complete array of report options. Include Image Sets the symbol quality report output to include a captured image of the symbol being analyzed. Bitmap and JPEG image formats are both available. Bitmap images, although higher resolution, have larger file sizes and take longer to load.
FIS-6300 ESD Imager User’s Manual
2-9
Page 34
Menu Toolbar
Advanced Tab
The Auto Sync dialog at the top of the Advanced tab allows you to determine whether Auto Sync will be automatically enabled in sections of ESP where it is used, or if it will ask you before it enables Auto Sync functions. Always Ask Before Auto Sync Occurs If you check this option box, you are then able to determine what specific Auto Sync functions will be enabled. Receive Settings from the Reader will automatically send the Imager’s settings to ESP when Auto Sync is enabled. Send ESP Settings to the Reader will automatically send all Imager configuration settings chosen in ESP to the Imager. Do Not Send or Receive Settings creates a condition in which Auto Sync will not send Imager settings to ESP, or send ESP settings to the Imager. Show Targeting Pattern During Calibrate and Locate Allows you to determine whether the blue LED target pattern will be on or off during the Locate and Calibrate routines. Send XON with Autoconnect Sends an XON (Begin Transmission) command to the Imager before starting the Autoconnect routine.
2-10
FIS-6300 ESD Imager User’s Manual
Page 35
Using ESP
Document Memo The information you type in the Document Memo field will appear in a context-sensitive text box whenever your cursor hovers over the Document Memo item on the Options menu.
Model Memo Similar to Document Memo, the information you type in the Model Memo field will appear in a context-sensitive text box whenever your cursor hovers over the Model Memo item on the Options menu. Memos created in Model Memo are specific to the model enabled when the message was created.
Note: Memos must be saved in a .esp file if you want them to available in your next session. If you do not save your current session, any memos that you have entered during the session will be discarded, and will be unavailable in your next session.
FIS-6300 ESD Imager User’s Manual
2-11
Page 36
Connecting
Connecting • Click Start when the Autoconnect dialog appears.
• If your communications port is not the default COM1, use the pulldown menu to change your port.
• Once you have chosen the correct port, click Start to connect.
When you are connected, you will see the green connection indicator in the status bar at the bottom right of your screen:
• If the connection attempt fails, click the Autoconnect button, select a different communications port, and try again.
Note: If your RS-232 host settings cannot be changed to match the Imager’s settings, check the Force Connect box.
2-12
FIS-6300 ESD Imager User’s Manual
Page 37
Using ESP
View The View menu allows you to move quickly between interfaces without using the icon buttons on the App Mode toolbar. It also allows you to access the Bar Code Dialog.
Bar Code Dialog In the Bar Code Dialog you can create symbols by typing the text you wish to encode. This is a useful tool for creating configuration symbols, allowing you to configure your Imager by reading the symbols you create.
Drag specific configuration values from the control tree directly into this field to encode new symbols. Choose a spatial orientation for the new symbol. Set a humanreadable caption for the symbol that matches the encoded data, or write your own caption.
The symbol you create will be displayed in the field at the bottom of the Bar Code Dialog.
FIS-6300 ESD Imager User’s Manual
2-13
Page 38
Navigating in ESP
Navigating in ESP To change Imager settings, or to access the Utilities, Camera, Terminal, or Output Format views, click the App Mode button.
To return to EZ Mode, click the EZ Mode button.
To make changes to configuration settings in the control trees:
1. Left click on the + to expand menu items.
The X denotes the default option setting.
2. Double-click the desired parameter and single-click in the selection box to view options. 3. Place your cursor in the selection box, scroll down to the setting you want to change, and single-click the setting. 4. Left click again on the open screen to complete the selection. 5. Right click on the open screen and select Save to Reader to implement the command in the Imager. You can send the command without saving it, or you can send and save the command simultaneously.
2-14
FIS-6300 ESD Imager User’s Manual
Page 39
Using ESP
Send/Receive Options To access Receive, Save and Default options, click the Send/Recv button. You can also access these options by right-clicking in any of the configuration views.
Receiving From the Send/Recv menu, select Receive Reader Settings. Caution: Do not select this option if you do not want to upload the Imager’s settings. For example, if your ESP file has a number of custom settings that you want to maintain and download into the Imager, these settings would be lost by choosing Yes. This is useful if you want to receive (upload) the Imager’s settings and save them as a file for future use. For example, if your Imager has settings that you do not want to change, choosing Yes would allow you to load those settings to ESP and save them in an ESP file for later retrieval. Receiving the Imager’s settings will also assure that you will not be subsequently saving any unwanted changes that you or someone else has made previously in ESP.
Saving 1. Send, No Save (<A>) This saves ESP settings to current memory. 2. Send and Save (<Z>) This activates all changes in current memory and saves to the Imager for power-on. 3. Send and Save as Customer Defaults (<Zc>) Use this option to save your own default settings for quick retrieval with a <Zrc> command. This option will be visible only if you had checked Enable ‘Send and Save as Customer Defaults’ in the ESP Preferences dialog.
FIS-6300 ESD Imager User’s Manual
2-15
Page 40
Send/Receive Options
Defaulting When you select Default Current Menu Settings or Default all ESP Settings, you are only defaulting the ESP settings.
Advanced Options Send Current View This is the same as Save to Reader > Send No Save except that only the commands in the current configuration tree are sent.
Send Current Command This is the same as Send Current View , except that it saves only the command that is currently selected.
Add / Remove Exception After you perform a Receive Reader Settings command1 and you click on the Add Exception option, you may see a list of serial commands. These are commands that may be in your Imager’s firmware, but not included in, or different from, your current version of ESP. You can edit these commands by double-clicking on them and changing them as needed. It is important to note that these commands will be saved to your Imager whenever you send a Save to Reader command, or an <A> or a <Z> command. Also, if there is a corresponding ESP menu item, the ESP Value column for that item will be blank following a Receive Reader Settings command.
1. From the Send/Recv button or by right-clicking from within the configuration trees.
2-16
FIS-6300 ESD Imager User’s Manual