Page 11
1 Quick Start Contents Step 1 Check Required Hardware ................................................................................................ 1-2 Step 2 Connect the System .......................................................................................................... 1-3 Step 3 Position Imager and Symbol.............................................................................................. 1-4 Step 4 Install ESP ......................................................................................................................... 1-5 Step 5 Select Model...................................................................................................................... 1-6 Step 6 Autoconnect....................................................................................................................... 1-7 Step 7 Locate the Symbol in the FOV........................................................................................... 1-8 Step 8 Calibrate Settings ........................................................................................................... 1-10 Step 9 Test Read Rate .............................................................................................................. 1-11 Step 10 Configure the Imager Using ESP ................................................................................. 1-12 Step 11 Make Menu Changes and Save in ESP ....................................................................... 1-13
This chapter is designed to get your FIS-6300 ESD Imager up and running quickly, using the EZ button or ESP (Easy Setup Program). Following these steps will allow you to get a sense of the Imager’s capabilities and to test sample symbols. Detailed setup information for installing the Imager into your actual application can be found in the subsequent chapters.
FIS-6300 ESD Imager User’s Manual
1-1
Page 12
Check Required Hardware
Step 1, Check Required Hardware Item 1 2 3
Description FIS-6300 Imager IC-332 Adapter IB-131 Interface
4
Power Supply
5 6 wenglor Sensor (optional) Host Cable
Part Number FIS-6300-110x SD15SD15U AB-1120 NT06US (110V) or NT06 (220V) BD25BD9V01-2M
1 2
Host
6
Network
Scanner
3
4
5
Hardware Required
1-2
FIS-6300 ESD Imager User’s Manual
Page 13
Quick Start
Step 2, Connect the System Connecting by RS-232 / RS-422 / RS-485 • Connect the Imager (1) to the IB-131/IC-332 interface (2) and (3). • Connect the host cable (6) to the host and to the host port on the IB-131 (3). • Connect the object detector (5) to the IB-131 (3). • Connect the power supply (4) to the IB-131 (3). • Apply power to the Imager.
1 2
Host
Network
Scanner
6
3
4
5
Hardware Configuration Caution: Be sure that all cables are connected BEFORE applying power to the system. Always power down BEFORE disconnecting any cables.
FIS-6300 ESD Imager User’s Manual
1-3
Page 14
Position Imager and Symbol
Step 3, Position Imager and Symbol • Position the Imager at a focal distance between 2” and 6” from the symbol. • Tip the Imager relative to the symbol to avoid the glare of direct (specular) reflection. The case parting line should be perpendicular to the plane of the symbol by either pitching the symbol or the Imager as shown. • Position the Imager in a place with as little ambient light as possible. • Symbols can be rotated (tilted) at any angle; however, for best results symbols should be aligned with the FOV (field of view).
±30°
Imager Position Relative to Symbol • In the case of linear symbols, aligning the bars in the direction of their movement (“ladder” orientation) will minimize the chances of blurring, and will produce better reads. • Avoid excessive skew or pitch. Maximum skew is ±30°; maximum pitch is ±30°. Note: For instant setup and validation, the FIS-6300 ESD can be hand-held or placed on its side. For accuracy, however, a mounting arm adapter kit is recommended.
1-4
FIS-6300 ESD Imager User’s Manual
Page 15
Quick Start
Step 4, Install ESP (ESP stands for Easy Setup Program.) Once your Imager is connected to a host computer with Windows™ operating system (98 or above), you can use ESP for configuration and control.
To install ESP from a CD: • Insert your wenglor CD ROM (ZUB-FIS-GB) in your computer’s CD drive. • Select the “Configuration Software” file, launch Setup.exe under “wenglor ESP”, and follow the prompts.
To download ESP from the Web: • Go to http://www.wenglor.de. • Navigate through the following sequence: Download > Software > Barcode Scanner • Click the Download button and store the ESP.zip file to the location of your choice on your hard drive. • Extract the wenglor ESP WinZip files to a directory of your choice. • At the end of the installation process, copy a shortcut ESP icon onto your desktop.
• Click the ESP icon to start the program.
FIS-6300 ESD Imager User’s Manual
1-5
Page 16
Select Model
Step 5, Select Model When you start ESP, the following menu will appear:
• Select FIS-6300 ESD from the menu and click OK. If you do not want to make this selection every time you start ESP, uncheck “Show this window at Startup”. • Click Yes when this dialog appears:
Note: If you need to select another model later, click the Switch Model button near the top of the screen. 1-6
FIS-6300 ESD Imager User’s Manual
Page 17
Quick Start
Step 6, Autoconnect • Click Start when the Autoconnect dialog appears.
• If your communications port is not the default COM1, use the pulldown menu to change your port.
• Once you have chosen the correct port, click Start to connect.
When you are connected, you will see the green connection indicator in the status bar at the bottom right of your screen:
• If the connection attempt fails, click the Autoconnect button, select a different communications port, and try again. Note: If your RS-232 host settings cannot be changed to match the Imager’s settings, check the Force Connect box. Important: The Imager is in Continuous Read Mode by default. For best connection results, be sure that no symbols are within the Imager’s field of view while attempting to connect. FIS-6300 ESD Imager User’s Manual
1-7
Page 18
Locate the Symbol in the FOV
Step 7, Locate the Symbol in the FOV • Move the symbol or the Imager so that the blue target pattern is centered over the symbol. At 2 to 3 inches, the pattern resembles an X. At 3 to 6 inches, the pattern resembles a V. It is important for the whole symbol to fall within the field of view (FOV) of the Imager. The field of view is what appears in ESP’s Locate/Calibrate window.
Center on symbol in field of view.
Target pattern shown as it would appear between 3 and 6 inches.
Locate by EZ Button If you are not connected to a host computer, the EZ button will allow you to locate a symbol in the Imager’s FOV.
EZ Button
• Hold down the EZ button for about one second and release when you hear one short beep. The amber 20% LED will illuminate, and you will see the blue target pattern projected from the front of the Imager. • Center the target pattern on the symbol. Note: To end all EZ button functions, press the EZ button once and quickly release.
1-8
FIS-6300 ESD Imager User’s Manual
Page 19
Quick Start
Locate by ESP • In ESP’s EZ Mode, click the Locate button to enable the target pattern.
You will see the blue target pattern projected from the front of the Imager. • Center the target pattern over the symbol you wish to read.
Center on symbol in field of view.
Target pattern shown as it would appear between 3 and 6 inches.
• Click the Stop button to end the Locate function.
FIS-6300 ESD Imager User’s Manual
1-9
Page 20
Calibrate Settings
Step 8, Calibrate Settings FIS-6300 ESD image settings can be adjusted automatically for optimum readability by either the EZ button or by ESP. During the calibration routine, the Imager will flash its amber read rate percent LEDs and red illumination LEDs while searching through various focus and camera settings and determining the best configuration for decoding symbol data. Upon successful completion of this routine, a green LED pattern will flash brightly and illuminate the symbol. If unsuccessful, the Imager will emit 5 short beeps and stop searching.
Calibrate by EZ Button 1. Hold down the EZ button about two seconds and release when you hear two short beeps. The 20% and 40% LEDs will illuminate. 2. The Imager will search through various focus settings and camera settings to determine the best configuration for decoding symbol data. Important: The object must be centered in the field of view for the calibration process to be successful. Note: To end all EZ button functions, press the EZ button once and quickly release.
Calibrate by ESP 1. Click the Calibrate button.
2. The Imager will search through various focus settings and camera settings to determine the best configuration for decoding symbol data. A successful calibration will display a green frame around the symbol, and the following message will appear: “Uploading all reader parameters.” After a moment the symbol’s data and related features will be presented under the “Symbol Information” box below the image display window.
Calibrate by Serial Command Send <@CAL> to begin calibration. 1-10
FIS-6300 ESD Imager User’s Manual