Page 131
Symbologies
Code 93 Usage: Definition: Serial Cmd: Default: Options:
Sometimes used in clinical applications. Code 93 is a variable-length, continuous symbology employing four element widths. Each Code 93 character has nine modules that may be either black or white. Each character contains three bars and three spaces. <K475,status,fixed symbol length status,symbol length> Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (Code 93) Definition:
Serial Cmd: Default: Options:
When disabled, the Imager will accept any Code 93 symbol provided is doesn’t exceed the system’s maximum capabilities. When enabled, the Imager will reject any Code 93 symbol that doesn’t match the fixed symbol length. <K475,status,fixed symbol length status,symbol length> Disabled 0 = Disabled 1 = Enabled
Symbol Length (Code 93) Definition: Serial Cmd: Default: Options:
This is the symbol length value against which all Code 93 symbols will be compared. <K475,status,fixed symbol length status,symbol length> 10 1 to 64
FIS-6300 ESD Imager User’s Manual
6-17
Page 132
Codabar
Codabar Usage: Definition: Serial Cmd: Default: Options:
Used in photo-finishing and library applications. Previously used in medical applications, but not typically used in newer medical applications. Codabar is a 16-bit character set (0 through 9, and the characters $, :, /, ., +, and –) with start/stop codes and at least two distinctly different bar widths. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output> Disabled 0 = Disabled 1 = Enabled
Start / Stop Match (Codabar) Definition:
Serial Cmd: Default: Options:
When disabled, the Imager will decode Codabar symbols whether or not the start and stop characters are the same. When enabled, the Imager will not decode Codabar symbols unless the start and stop characters are the same. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output> Enabled 0 = Disabled 1 = Enabled
Start / Stop Output (Codabar) Definition:
Serial Cmd: Default: Options:
6-18
When disabled, the start and stop characters will not be present in the data output of the decoded symbol. When enabled, the start and stop characters will be present in the data output of the decoded symbol. Note: Because the start and stop characters are included as part of the data, the characters must be included as part of the length in a fixed length mode of operation. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output> Enabled 0 = Disabled 1 = Enabled
FIS-6300 ESD Imager User’s Manual
Page 133
Symbologies
Large Intercharacter Gap (Codabar) Definition:
Serial Cmd: Default: Options:
When disabled, the spaces between characters, or the “inter-character gap”, are ignored during the decode process. Note: If the inter-character space is large enough to be considered a margin, the symbol will not decode, regardless of this parameter’s setting. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output> Disabled 0 = Disabled 1 = Enabled
Fixed Symbol Length Status (Codabar) Definition:
Serial Cmd: Default: Options:
When disabled, the Imager will accept any Codabar symbol provided it doesn’t exceed the system’s maximum capabilities. When enabled, the Imager will reject any Codabar symbol that doesn’t match the fixed length. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output> Disabled 0 = Disabled 1 = Enabled
Symbol Length (Codabar) Definition: Serial Cmd: Default: Options:
This is the value against which all Codabar symbol lengths will be compared. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output> 10 1 to 64
FIS-6300 ESD Imager User’s Manual
6-19
Page 134
Codabar
Check Digit Type (Codabar) Definition:
Serial Cmd: Default: Options:
When disabled, the Imager will not perform any character checking calculations on decoded Codabar symbols. When set to Mod 16, the Imager will perform a modulus 16 check character calculation on the symbol. If the symbol does not pass this calculation, it will not be decoded. When set to NW7, The Imager will perform an NW7 modulus 11 check character calculation on the symbol. If the symbol does not pass this calculation, it will not be decoded. When set to Both, the Imager will perform both the Mod 16 and NW7 modulus 11 check character calculations on the symbol. If the symbol does not pass either calculation, it will not be decoded. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output> Disabled 0 = Disabled 1 = Mod 16 2 = NW7 (Mod 11) 3 = Mod 16 and NW7
Check Digit Output (Codabar) Definition:
Serial Cmd: Default: Options:
6-20
When this field is disabled and a check digit calculation is enabled, the Imager will strip the verified check digit from the symbol data output. This condition must be accounted for if a fixed length is also being used. When enabled, the Imager will output the check character as part of the symbol data. This condition must be accounted for if a fixed length is also being used. <K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check digit type,check digit output> Disabled 0 = Disabled 1 = Enabled
FIS-6300 ESD Imager User’s Manual
Page 135
Symbologies
UPC / EAN Usage:
Definition:
Serial Cmd: Default: Options:
Used primarily in POS application in the retail industry. It is commonly used with wenglor readers in applications in combination with Matchcode when there is a need to verify that the right product is being placed in the right packaging. UPC (Universal Product Code) is a fixed length, numeric, continuous symbology. UPC can have two- or five-digit supplemental bar code data following the normal code. The UPC Version A (UPC, A) symbol is used to encode a 12 digit number. The first digit is the number system character, the next five are the manufacturer number, the next five are the product number, and the last digit is the checksum character. When enabled, the Imager will read UPC Version A and UPC Version E only. <K473,UPC status,EAN status,supplementals status,separator status,separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled
1 = Enabled
EAN Status Usage: Definition:
Serial Cmd: Default: Options:
EAN is the European version of the UPC symbology and is used in European market applications. Note: UPC must be enabled for EAN to take effect. EAN is a subset of UPC. When enabled, the Imager will read UPC Version A, UPC Version E, EAN 13, and EAN 8. It also appends a leading zero to UPC Version A symbol information and transmits 13 digits. If transmitting 13 digits when reading UPC Version A symbols is not desired, disable EAN. Note: The extra character identifies the country of origin. <K473,UPC status,EAN status,supplementals status,separator status,separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled
FIS-6300 ESD Imager User’s Manual
1 = Enabled
6-21
Page 136
UPC / EAN
Supplementals Status (UPC / EAN) Usage: Definition: Serial Cmd: Default: Options:
Reads Supplementals typically used in publications and documentation. A supplemental is a 2 to 5 digit symbol appended to the main symbol. When set to Enabled or Required, the Imager reads supplemental code data that has been appended to the standard UPC or EAN codes. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled 1 = Enabled 2 = Required
Disabled UPC Supplementals will not be decoded.
Enabled When enabled, the Imager will try to decode a main and a supplemental. However, if a supplemental is not decoded, the main will be sent by itself at the end of the read cycle.
Required When set to Required, both the main and the supplemental symbols must be read or a single “noread” condition results. For example, if Supplementals is set to Required, Separator is enabled, and an asterisk is defined as the UPC separator character. Then the data is displayed as: MAIN * SUPPLEMENTAL. Note: Under no circumstances will the supplemental symbol data be sent without a main symbol. Note: If additional symbols - other than the main or supplemental - will be read in the same read cycle, Number of Symbols should be set accordingly.
Separator Status (UPC / EAN) Usage: Definition: Serial Cmd: Default: Options:
6-22
Allows users to distinguish between the main and Supplemental symbols. A character can be inserted between the standard UPC or EAN symbology and the supplemental symbology when Supplementals is set to Enabled or Required. <K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled
1 = Enabled
FIS-6300 ESD Imager User’s Manual
Page 137
Symbologies
Separator Character (UPC / EAN) Note: If Separator Character has been changed to any other character and you wish to redefine the separator as a comma, you will need to use ESP. Usage: Definition: Serial Cmd: Default: Options:
As required by the application. Allows the user to change the separator character from a comma to a new character. <K473,UPC status,EAN status,supplementals status,separator status,separator character,supplemental type,format UPC-E as UPC-A> , (comma) Any ASCII character.
Note: Whenever Separator Character is defined as a comma ( , ) sending a <K473,s?> command will return the current settings, including the separator character comma which appears after the separator status comma. Important: The ASCII characters <, >, and , can only be entered as hex pairs: For <: <K473h,,,,,3C> For >: <K473h,,,,,3E> For , : <K473h,,,,,2C> See ASCII Character Entry Modifier on page 3-23 for a detailed explanation of how to enter ASCII characters as hex values.
FIS-6300 ESD Imager User’s Manual
6-23
Page 138
UPC / EAN
Supplemental Type (UPC / EAN) Usage: Definition: Serial Cmd: Default: Options:
As required by symbology used in application. Allows the user to select 2 character or 5 character supplements, or both. <K473,UPC status,EAN status,supplementals status,separator status,separator character,supplemental type,format UPC-E as UPC-A> Both 0 = Both 1 = 2 characters only 2 = 5 characters only
Both Either 2 character or 5 character supplementals will be considered valid.
2 Characters Only Only two character supplementals will be considered valid.
5 Characters Only Only five character supplementals will be considered valid.
Format UPC-E as UPC-A (UPC / EAN) Definition:
Serial Cmd: Default: Options:
6-24
When disabled, the Imager will output the version E symbols in their encoded 6-character format. When enabled, the Imager will format the symbol as either a 12-character UPC-A symbol or an EAN-13 symbol, depending on the state of the EAN status parameter. This formatting reverses the zero suppression that is used to generate the symbol in the UPC specification. <K473,UPC status,EAN status,supplementals status,separator status,separator character,supplemental type,format UPC-E as UPC-A> Disabled 0 = Disabled 1 = Enabled
FIS-6300 ESD Imager User’s Manual
Page 139
Symbologies
Pharmacode Usage: Definition:
Serial Cmd: Default: Options:
Used mostly with packaging for the pharmaceuticals industry. Encodes up to five different numbers, each with its own color, which may be entered in decimal or “binary” format with a 1 represented by a thick bar and a 0 represented by a thin bar. Bar width is independent of height. In decimal format, each part can be up to 999,999. In binary format, each input can have up to 19 ones and zeros. <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> Disabled 0 = Disabled
1 = Enabled
Fixed Symbol Length Status (Pharmacode) Definition: Serial Cmd: Default: Options:
When enabled, the Imager will check the symbol length against the symbol length field. If disabled, any length will be considered valid. <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> Disabled 0 = Disabled
1 = Enabled
Fixed Symbol Length (Pharmacode) Definition: Serial Cmd: Default: Options:
This specifies the exact number of characters that the Imager will recognize. The Imager ignores any symbology not having the specified length. <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> 5 1 to 16
Minimum Number of Bars (Pharmacode) Definition: Serial Cmd: Default: Options:
Sets the minimum number of bars that a Pharmacode symbol must have to be considered a valid symbol. <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> 2 1 to 16
FIS-6300 ESD Imager User’s Manual
6-25
Page 140
Pharmacode
Bar Width Status (Pharmacode) Definition:
Serial Cmd: Default: Options:
If set to Mixed, the Imager will autodiscriminate between narrow bars and wide bars. If set to All Narrow, all bars will be considered as narrow bars. If set to All Wide, all bars will be considered as wide bars. If set to Fixed Threshold, it will use the Fixed Threshold value to determine whether the bars are narrow or wide. The Bar Width Status setting will be ignored when the Imager is able to tell the difference between the narrow and the wide bars. <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> Mixed 0 = Mixed 1 = All Narrow 2 = All Wide 3 = Fixed Threshold
Direction (Pharmacode) Definition: Serial Cmd: Default: Options:
Specifies the direction in which a symbol can be read. <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> Forward 0 = Forward
1 = Reverse
Fixed Threshold Value (Pharmacode) Definition: Serial Cmd: Default: Options:
6-26
Used when Bar Width Status is set to Fixed Threshold. Defines the minimum difference in pixels that will distinguish a narrow bar from a wide bar. <K477,status,fixed symbol length status,fixed symbol length,minimum number of bars,bar width status,direction,fixed threshold value> 10 1 to 65535