Wenglor FIS-6300 Quick Start Guide

Manual2 pagesPDF 1.0 MB

Both pages are below, each with its text.

Download the PDF1.0 MB

Covers · 1 model

The models it covers

From the manual · read page by page

Key facts from this manual

Each line names its page in the PDF.

A two-page wenglor quick start guide (P/N 83-736300 Rev A, 2005) for the FIS-6300 Imager. It shows how to wire the imager through the IB-131 interface box, position it over a symbol, install the ESP setup program, then connect, calibrate, test the read rate and save settings.

Device
Imager that decodes symbols, set up with the ESP (Easy Setup Program), the EZ button or serial commands p. 2
Host interfaces
RS-232, RS-422 or RS-485 through the IB-131 interface box p. 1
Focal distance
Between 2” and 6” p. 1
Skew and pitch
Maximum ±30° skew and ±30° pitch p. 1
Interface box
IB-131 Interface Box, part number AB1120 p. 1
Adapter
IC-332 Adapter, part number SD15SD15U p. 1
Power supply
NT06US (110V); NT06 (220V) p. 1
Setup software
ESP for Windows 98 or above, from the wenglor CD ROM (ZUB-FIS-GB) or download p. 1
Default read mode
Continuous Read Mode p. 1, 2
Target pattern
Blue; looks like an X at 2 to 3 inches and a V at 3 to 6 inches p. 2
EZ button
Hold about 1 s to locate, 2 s to calibrate, 3 s for the read rate test p. 2
Read rate LEDs
20%, 40%, 60%, 80%, 100% of good reads per images captured, on the back of the unit p. 2
Serial commands
<@CAL> starts calibration; <C> or <Cp> starts a read rate test, <J> ends it p. 2

What this manual walks you through

  • Connecting the imager, interface box, object detector, host cable and power supply p. 1
  • Positioning the imager to avoid glare and blurring p. 1
  • Installing ESP from the CD or a download p. 1
  • Connecting ESP to the imager with Autoconnect p. 2
  • Locating the symbol with the target pattern p. 2
  • Calibrating by EZ button, ESP or serial command p. 2
  • Testing the read rate p. 2
  • Changing configuration settings in ESP and saving them to the reader p. 2

Good to know

  • Connect all cables before applying power, and power down before disconnecting any cable. p. 1
  • Keep symbols out of the field of view while connecting, since the imager reads continuously by default. p. 2
  • Changes sent with Send, No Save are lost when power is applied again. p. 2
  • A failed calibration ends with 5 short beeps; the symbol must be centered in the field of view. p. 2
  • For accuracy a mounting arm adapter kit is recommended rather than holding the imager. p. 1

Questions this manual answers

What reading distance does the wenglor FIS-6300 need?

The guide says to place the imager at a focal distance between 2” and 6” from the symbol. p. 1

What software configures the FIS-6300?

ESP (Easy Setup Program), which runs on Windows 98 or above and comes on the wenglor CD ROM or as a download. p. 1

How do I calibrate the FIS-6300 without a computer?

Hold the EZ button for about two seconds until two short beeps; the imager then searches its camera and IP settings for the best configuration. p. 2

What does the FIS-6300 power supply part number depend on?

The mains voltage: NT06US for 110V and NT06 for 220V. p. 1

The file

Size and text

Pages2
PDF1.0 MB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Wenglor FIS-6300 Quick Start Guide

The text of page 1, from the PDF itself

Quick Start GuideFIS-6300 ImagerStep 1, Check Hardware

Step 2, Connect the System Connecting by RS-232 / RS-422 / RS-485

1 2

Connect the Imager (1) to the IB-131/IC-332 interface (2) and (3). Connect the host cable (6) to the host and to the host port on the IB-131 (3). Connect the object detector (5) to the IB-131 (3). Connect the power supply (4) to the IB-131 (3). Apply power to the Imager.

HostNetworkScanner631 2 5ScannerHost6Hardware RequiredNetwork43

Caution: Be sure that all cables are connected BEFORE applying power to the system. Always power down BEFORE disconnecting any cables. 4

P/N 83-736300 Rev A

Step 3, Position Imager

  • Position the Imager at a focal distance between 2” and 6”.
  • Tip the Imager relative to the symbol to avoid the glare of direct (specular) reflection. The case parting line should be perpendicular to the plane of the symbol by either pitching the symbol or the Imager as shown.
  • Position the Imager in a place with as little ambient light as possible.
  • Symbols can be rotated (tilted) at any angle; however, for best results symbols should be aligned with the FOV (field of view).
  • In the case of linear symbols, aligning the bars in the direction of their movement (“ladder” orientation) will minimize the chances of blurring, and will produce better reads.
  • Avoid excessive skew or pitch. Maximum skew is ±30°; maximum pitch is ±30°.

Item 1 2 3 4 5 6

Description FIS-6300 Imager

FIS-6300-XXXXIC-332 AdapterSD15SD15UIB-131 Interface BoxAB1120Power Supply

NT06US (110V); NT06 (220V)

wenglor Sensor Host Cable

Step 4, Install ESP (ESP stands for Easy Setup Program.)

Copyright © 2005 wenglor sensoric gmbh

Caution: Be sure that all cables are connected BEFORE applying power to the system. Always power down BEFORE disconnecting any cables.

Step 5, Select Model When you start ESP, this menu will appear:

Once your Imager is connected to a host computer with Windows™ operating system (98 or above), you can use ESP (Easy Setup Program) for configuration and control. To install ESP from a CD:

  • Insert your wenglor CD ROM (ZUB-FIS-GB) in your computer’s CD drive.
  • Select the “Configuration Software” file, launch Setup.exe under “wenglor ESP”, and follow the prompts. To download ESP from the Web:

±30°

Note: For instant setup and validation, the FIS-6300 can be hand-held or placed on its side. For accuracy, however, a mounting arm adapter kit is recommended.

Hardware Configuration

BD25BD9V01-2M

  • Go to http://www.wenglor.de.
  • Navigate through the following sequence: Download > Software > Barcode Scanner
  • Click the Download button and store the ESP.zip file to the location of your choice on your hard drive.
  • Extract the wenglor ESP WinZip files to a directory of your choice. Remember where your ESP.exe file is stored on your hard drive!
  • At the end of the install process, copy a shortcut ESP icon onto your desktop.

Imager / Symbol Positioning

5

Part Number

  • Click the ESP icon to run the program.
  • Select the FIS-6300 from the menu and click OK. If you do not want to make this selection every time you start ESP, uncheck “Show This Window at Startup”.
  • Click Yes when this dialog appears:

Note: If you need to select another reader model later, click the Switch Model button near the top of the screen. Important: The Imager is in Continuous Read Mode by default. For best connection results, be sure that no symbols are within the Imager’s field of view while attempting to connect.

Page 2 of Wenglor FIS-6300 Quick Start Guide

The text of page 2, from the PDF itself

Step 6, Autoconnect Important: The Imager is in Continuous Read Mode by default. For best results, be sure that no symbols are within the Imager’s field of view while attempting to connect.

  • Click Start when the Autoconnect dialog appears.

Step 7, Locate the Symbol Move the symbol or the Imager so that the blue target pattern is centered over the symbol. At 2 to 3 inches, the pattern resembles an X. At 3 to 6 inches, the pattern resembles a V. It is important for the whole symbol to fall within the field of view (FOV) of the Imager. The field of view is what appears in ESP’s Locate/Calibrate window.

Locate by EZ Button

Center on symbol in field of view.

Target pattern shown as it would appear between 3 and 6 inches.

If you are not connected to a host computer, the EZ button will allow you to locate a symbol in the Imager’s FOV.

  • If your communications port is not the default COM1, use the dropdown menu to change your port.
  • Hold down the EZ button for about one second and release when you hear one short beep. You will see the blue target pattern.
  • Center the target pattern on the symbol.
  • Once you have chosen the correct port, click Start to connect.

Note: To end all EZ button functions, press the EZ button once and quickly release.

When you are connected, you will see the green connection indicator in the status bar at the bottom right of your screen:

If the connection attempt fails, click the Autoconnect button, select a different communications port, and try again. Note: If your RS-232 host settings cannot be changed to match the Imager’s settings, check the Force Connect box.

Step 9, Test Read Rate This test will let you know the percent of good reads per images captured.

Testing by EZ Button 1. To start the read rate test, hold down the EZ button about three seconds until you hear three short beeps. While the symbol is being decoded, the read rate LEDs will indicate the corresponding read rate percentage on the back of the unit. 2. To end the read rate test, press the EZ button and quickly release.

In ESP’s EZ Mode, click the Locate button to enable the target pattern. You will see the blue target pattern projected from the front of the Imager.

  • Center the target pattern over the symbol you wish to read.
  • Click the Stop button to end the Locate function.

Step 10, Configure the Imager Using ESP

The following modes are accessible by clicking the buttons in the first row of App Mode icons:

Testing by ESP 1. Click the Test button to start the read rate test and Stop to end it.

The Imager can be optimized by the EZ button, ESP, or serial command. During calibration, the Imager will flash its LEDs while determining the best configuration for decoding symbol data. Upon successful completion, a green LED pattern will flash brightly and illuminate the symbol. If unsuccessful, the Imager will emit 5 short beeps and stop searching.

Calibrate by EZ Button 1. Hold down the EZ button for about two seconds and release when you hear two short beeps. 2. The Imager will search through various camera and IP settings to determine the best configuration for decoding symbol data. Important: The object must be centered in the field of view for the calibration process to be successful. Note: To end all EZ button functions, press the EZ button once and quickly release.

Calibrate by ESP 1. Click the Calibrate button in EZ Mode.

Locate by ESP

To make setup changes to the FIS-6300, click the App Mode button.

20%, 40%, 60%, 80%, 100%. These LEDs represent the percentage of good reads per images captured.

Step 8, Calibrate Settings

  • Establish communications between ESP and the Imager by clicking the Autoconnect button.
  • Send or receive commands by clicking the Send/Recv button.
  • Make changes to Camera options by clicking the Camera button.
  • Access the Terminal window, where you can see symbol data and enter serial commands, by clicking the Terminal button.
  • Review status settings or make changes to operational commands by clicking the Utilities button.
  • Format data for output by clicking the Data Output Format button.

2. The Imager will search through various camera and IP settings to determine the best configuration for decoding symbol data. A successful calibration will display a green frame around the symbol, and the following message will appear: “Uploading all reader parameters.” After a moment the symbol’s data and related features will be presented under the “Symbol Information” box below the image display window. Calibrate by Serial Command Send <@CAL> to the Imager to begin the calibration routine.

Step 11, Make Menu Changes and Save in ESP To make changes to a configuration setting: 1. Left click on the

  • to expand the desired tree. 2. Double click on the desired parameter and click once in the selection box to view options. 3. Place your cursor in the selection box, scroll down to the setting you want to change, and click once on the setting.

Click the Configuration button to display the second row of ESP icons. If your symbol has been successfully decoded, its data and related features will be presented under “Symbol Information.” Also, while the symbol is being decoded, the read rate LEDs will indicate the corresponding read rate percentage on the back of the unit. 2. To end the test, click the Stop button.

Testing by Serial Command

Saving Options From here you can make changes in the configuration trees that can be accessed by clicking the buttons on the second row of icons in the ESP window.

You can also start a test with the <C> or <Cp> command and end it with the <J> command. For further details, see ESP Help in the pulldown Help menu. Copyright © 2005 wenglor sensoric gmbh

4. Left click again on the open screen to complete your selection.

5. Right click on the open screen and select Save to Reader to implement the command in the Imager.

  • Send, No Save. Changes will be lost when power is re-applied to the Imager.
  • Send and Save. This activates all changes in current memory and saves to the Imager for power-on.