Page 13

FIS-0870 Industrial Raster Scanner Quick Start Help

FIS-0870 Industrial Raster Scanner User’s Manual

1-1

Page 14

Check Hardware Item 1 2 3 5 6 7 8

Description FIS-0870 Industrial Raster Scanner Interface Device AB-0830 Cordset, Common, M12 12-pin Plug to M12 12-pin Socket, 1 m Cordset, Host, Serial, M12 12-pin Socket to DB9, 1 m Power Supply, M12 12-pin Socket, 1.3 m Cordset, Host, Ethernet, M12 8-pin Plug to RJ45, 1 m Photo Sensor, M12 4-pin Plug, NPN, Dark On, 2 m

Part Number FIS-0870-XXXX AB-0830 ZAV12Rx01 ZAV13Rx01 NT-10 ZAV88Rx01

Note: Additional cordsets and accessories are available in the wenglor Product Pricing Catalog. Note: The FIS-0870 does not require an Ethernet crossover cordset, because the scanner itself performs automatic internal crossover (transmit-to-receive switching). wenglor offers a standard straight-through (un-crossed) Ethernet cordset (ZAV88Rx01).

Standalone (with Interface Device)

Standalone (without Interface Device)

Hardware Required Caution: Be sure that all connections are secure BEFORE applying power to the system. Always power down BEFORE disconnecting any cables.

1-2

FIS-0870 Industrial Raster Scanner User’s Manual

Page 15

Quick Start

Connect the System Important: When connecting Ultra-Lock cordsets to the FIS-0870 and Interface Device, align the pins first and then push the connector into place. Do not twist the connectors, as this will bend the pins. RS-232 • Connect the Serial Communication Cable from “A” on the FIS-0870 to “2” on the Interface Device. • Connect the host cable from “1” on the Interface Device to the host computer. • Connect the photo sensor to “T” on the Interface Device. • Connect the power supply to “3” on the Interface Device. • Plug in the power supply. Ethernet Note: The FIS-0870 does not require an Ethernet crossover cordset, because the scanner itself performs automatic internal crossover (transmit-to-receive switching). wenglor offers a standard straight-through (un-crossed) Ethernet cordset (ZAV88Rx01). • Connect the Ethernet Cable from “B” on the FIS-0870 to the network. • Connect the photo sensor to “T” on the Interface Device. • Connect the power supply to “A” on the FIS-0870. • Plug in the power supply.

Standalone (with Interface Device)

FIS-0870 Industrial Raster Scanner User’s Manual

Standalone (without Interface Device)

1-3

Page 16

Position Scanner and Symbol • Place a test symbol in a location with as little ambient light as possible. • Position the scanner at the focal distance used in the application. • Align the test symbol with the scanner’s field of view. • Tip the scanner relative to the test symbol to avoid glare from specular reflection. Bar code label axis Skew

Symbol

Tilt axis Tilt

Scanner

Scanner Scan line

1-4

Maximum skew, tilt, and pitch: ±30°

Pitch Pitch axis

FIS-0870 Industrial Raster Scanner User’s Manual

Page 17

Quick Start

Install ESP (ESP stands for Easy Setup Program.) ESP is wenglor’s proprietary reader setup and testing software. It is not meant to be a tool for a real-time production environment; the purpose of ESP is to provide a quick and easy way to set up and configure your reader. With your imager connected to a host computer (Windows Vista, XP, or 2000), you can use ESP for configuration and imager control. If installing from a wenglor CD: • Insert the wenglor CD (ZUB-CD-BS) in your computer’s CD drive. • Select the “Configuration Software” file, launch Setup.exe under “wenglor ESP”, and follow the prompts. If downloading from the web: • Go to http://www.wenglor.com • Navigate through the following sequence Download > Software > Barcode Scanner. • Click the Download button and store the ESP.zip file to the location of your choice on the host hard drive. • Extract the wenglor ESP WinZIP files to a directory of your choice. • At the end of the installation process, the following icon will appear on your desktop:

• Click the ESP icon to start the program. ESP System Requirements • 166 MHz Pentium processor (recommended) • Windows Vista, XP, or 2000 operating system • Internet Explorer 5.0 or higher • 64 MB minimum RAM • 40 MB minimum disk space • 800 x 600 pixel minimum 256 color display

FIS-0870 Industrial Raster Scanner User’s Manual

1-5

Page 18

Select Model When ESP is opened, the following menu will appear:

• Click the button showing the FIS-0870. • Click OK. Note: The FIS-0870 can also be selected by double-clicking the button showing the FIS-0870. • Click Yes when this dialog appears:

Note: To select another model later, click the Switch Model button near the top of the screen or use Model > New Model in the menu toolbar. 1-6

FIS-0870 Industrial Raster Scanner User’s Manual

Page 19

Quick Start

Connect To connect using the Connection Wizard: • Click Connect on the menu toolbar, and then select Connection Wizard. • Select RS-232 or Ethernet to activate the appropriate display. • Configure RS-232 or Ethernet settings as required by the application, and click Connect.

RS-232 Connection Wizard

Ethernet Connection Wizard

• When a connection is established, the green indicator in the status bar at the bottom right of the screen will be visible:

Important: The scanner is in Continuous Read Mode by default. For best connection results, be sure that no decodable symbols are within the scanner’s field of view while attempting to connect.

FIS-0870 Industrial Raster Scanner User’s Manual

1-7

Page 20

Ethernet TCP/IP Once the FIS-0870 is connected, incoming symbol data can be displayed in the Terminal, as shown below.

1-8

FIS-0870 Industrial Raster Scanner User’s Manual

Page 21

Quick Start

Test Read Rate Read Rate indicates the number or percentage of successful decodes per second achieved by the scanner. • Click the Test button in ESP’s EZ Mode to start the Read Rate test. Symbol data and read rate percentage information should appear in the Symbol Information table in the bottom portion of the view. The Read Rate LEDs on the side of the FIS-0870 will indicate the percentage of successful decodes per second. • Click Stop to end the Read Rate test. Note: Read Rate can also be tested using the Read Rate interface in Utilities.

FIS-0870 Industrial Raster Scanner User’s Manual

1-9

Page 22

Configure the Scanner Click the App Mode button to make configuration changes to the scanner.

The following modes are accessible by clicking the buttons at the top of the screen:

• Click the EZ Mode button to return to EZ Mode. • Click the Autoconnect button to establish communication. • Click the Send/Recv button to send or receive commands. • Click the Switch Model button to open the model menu, or to return to a previous model. • Click the Parameters button to show the tabbed tree control views. • Click the Setup button to show the tabbed interface views. • Click the Terminal button to display decoded symbol data and to send serial commands. • Click the Utilities button to access Read Rate, Counters, Device Control, Differences from Default, Master Database, Digital Bar Code, and Firmware. For further details, see Wenglor ESP Help in the dropdown Help menu.

1-10

FIS-0870 Industrial Raster Scanner User’s Manual

Page 23

Quick Start

Save Changes in ESP To make changes to a configuration setting:

3. Place the cursor in the selection box, scroll down to the setting to be changed, and click once on the setting.

1. Left-click on the + to expand the desired tree. 2. Double-click on the desired parameter and click once in the selection box to view options.

4. Left-click again on the open screen to complete the selection.

5. Right-click on the open screen and select Save to Reader to implement the command in the scanner.

Saving Options • Send, No Save. Changes will be lost when power is re-applied to the scanner. • Send and Save. This activates all changes in current memory and saves to the scanner for power-on.

FIS-0870 Industrial Raster Scanner User’s Manual