For the Wenglor FIS-0870
Page 378
Appendices
NET and MOD LED Indicators MOD (Module) Indicator State Summary
Requirement wenglor Implementation
If no power is supplied to the device, the Per requirement module status indicator will be steady OFF. If the device is operating correctly, the Device module status indicator will be steady Per requirement Steady GREEN operational GREEN. When operating If the device has not been configured, the with default Flashing Standby module status indicator will be flashing parameters. GREEN Default status is GREEN. updated at reset. 1. Temperature warning. If the device has detected a recoverable 2. Scan sync Flashing RED Minor fault minor fault, the module status indicator missing. This may occur briefly will be flashing RED. when the scan motor starts and stops. 1. Laser current warning. If the device has detected a non-recoverSteady RED Major fault able minor fault, the module status indi- 2. Safe Mode: Basic comm. only. cator will be steady RED. Scanning system is non-functional. While the device is performing its power- Per requirement, Flashing Self-test but unlikely to be up testing, the module status indicator GREEN / RED seen. will be flashing GREEN / RED. Steady OFF
No power
FIS-0870 Industrial Raster Scanner User’s Manual
A-91
Page 379
NET (Network) wenglor Implementation Per requirement. Before device has If the device does not have an IP No power, no address (or is powered off), the network acquired an IP Steady OFF IP address status indicator will be steady OFF. address via DHCP. Per requirement. If the device has no established connections, After device has Flashing but has obtained an IP address, the acquired an IP No connections GREEN network status indicator will be flashing address (static or GREEN. DHCP). If the device has at least one established connection (even to the Message Steady GREEN Connected Per requirement. Router), the network status indicator will be steady GREEN. Per requirement, If one or more of the connections in but limited. Flashing Connection which the device is the target has RED will only last Flashing RED timeout timed out, the network status indicator for 3 seconds, will be flashing RED. then will revert to flashing GREEN. If the device has detected that its IP Steady RED Duplicate IP address is already in use, the network Not implemented. status indicator will be steady RED. While the device is performing its Per requirement, Flashing Self-test power-up testing, the module status but unlikely to be GREEN / RED indicator will be flashing GREEN / RED. seen. Indicator State
A-92
Summary
Requirement
FIS-0870 Industrial Raster Scanner User’s Manual
Page 380
Appendices
Interface Standards Interface Standards, established by the Electronic Industries Association (EIA), specify such things as the signaling voltage levels, maximum cable lengths, and number of drivers. In the FIS-0870, selection of interface is made by pin assignment and, in the case of host communication, by software switching between RS-232 and RS-422/RS-485. RS-232 RS-232 defines an interface between two devices such as, for example, the scanner and host. It differs from the other interfaces by dedicating individual pins to specific functions and by requiring both devices to share a common ground line. Since both device chassis are connected to a common ground, a ground loop potential and the possibility of noise interference exists. Therefore cable lengths are limited to a maximum of 50 feet (19.7m). Despite being the most limited, this interface is used frequently because of the large installed base of RS-232 equipment. RS-422/RS-485 RS-422, unlike RS-232, measures signals deferentially; that is, the receiver looks at the potentials between the two receive (or transmit) wires rather than the potential between signal and ground. As a result, cables, if shielded, can be up to 4000 feet (1219m) in length. Like RS-232, RS-422 communication is designed for only two devices on a single line and must have a common ground. It can be used wherever RS-232 is used. Ethernet TCP/IP and EtherNet/IP TCP/IP and EtherNet/IP protocols are supported over Ethernet. A 6-byte hardware address is used, which is divided into a 3-byte vendor ID and a 3-byte vendor-defined field. Ethernet-enabled device manufacturers are assigned a unique vendor ID, and are then responsible for insuring that all of their devices have unique addresses in the last 3 bytes.
FIS-0870 Industrial Raster Scanner User’s Manual
A-93
Page 381
A-94
FIS-0870 Industrial Raster Scanner User’s Manual