Page 148

Scanner Parameters

Check Character Output Status When this field is disabled and a check character calculation is enabled, the scanner will strip the verified check character from the symbol data output. This condition must be accounted for if a fixed length is also being used. When enabled, the scanner will output the check character as part of the symbol data. This condition must be accounted for if a fixed length is also being used.

FIS-0870 Industrial Raster Scanner User’s Manual

5-81

Page 149

Symbologies

UPC/EAN Used primarily in point-of-sale applications in the retail industry. It is commonly used with Wenglor scanners in applications in combination with Matchcode when there is a need to verify that the right product is being placed in the right packaging. UPC (Universal Product Code) is a fixed length, numeric, continuous symbology. UPC can have two- or five-digit supplemental data following the normal symbol. The UPC Version A (UPC, A) symbol is used to encode a 12 digit number. The first digit is the number system character, the next five are the manufacturer number, the next five are the product number, and the last digit is the checksum character. When enabled, the scanner will read UPC Version A and UPC Version E only.

EAN Status EAN is the European version of the UPC symbology and is used in European retail applications. Note: UPC must be enabled for EAN to take effect. EAN is a subset of UPC. When enabled, the scanner will read UPC Version A, UPC Version E, EAN 13, and EAN 8. It also appends a leading zero to UPC Version A symbol information and transmits 13 digits. If transmitting 13 digits when reading UPC Version A symbols is not desired, disable EAN.

Note: The extra character identifies the country of origin.

5-82

FIS-0870 Industrial Raster Scanner User’s Manual

Page 150

Scanner Parameters

Supplementals Status Reads Supplementals typically used in publications and documentation. A supplemental is a 2 to 5 digit symbol appended to the main symbol. When set to Enabled or Required, the scanner reads supplemental code data that has been appended to the standard UPC or EAN codes.

Disabled UPC Supplementals will not be decoded.

Enabled When enabled, the scanner will try to decode a main and a supplemental. However, if a supplemental is not decoded, the main will be sent by itself at the end of the read cycle.

Required When set to Required, both the main and the supplemental symbols must be read or a single No Read condition results. For example, if Supplementals is set to Required, Separator is enabled, and an asterisk is defined as the UPC separator character. Then the data is displayed as: MAIN * SUPPLEMENTAL. Note: Under no circumstances will the supplemental symbol data be sent without a main symbol. Note: If additional symbols - other than the main or supplemental - will be read in the same read cycle, Number of Symbols should be set accordingly.

Separator Status Allows users to distinguish between the main and Supplemental symbols. A character can be inserted between the standard UPC or EAN symbology and the supplemental symbology when Supplementals is set to Enabled or Required.

FIS-0870 Industrial Raster Scanner User’s Manual

5-83

Page 151

Symbologies

Separator Character As required by the application. Allows the user to change the separator character from a comma to a new character. Note: Whenever Separator Character is defined as a comma ( , ) sending a <K473,s?> command from ESP’s Terminal will return the current settings, including the separator character comma which appears after the separator status comma.

Supplementals Type As required by symbology used in application. Allows the user to select 2 character or 5 character supplements, or both.

Both Either 2 character or 5 character supplementals will be considered valid.

Two Characters Only Only two character supplementals will be considered valid.

Five Characters Only Only five character supplementals will be considered valid.

5-84

FIS-0870 Industrial Raster Scanner User’s Manual

Page 152

Scanner Parameters

UPC-E as UPC-A When disabled, the scanner will output the version E symbols in their encoded 6-character format. When enabled, the scanner will format the symbol as either a 12-character UPC-A symbol or an EAN-13 symbol, depending on the state of the EAN status parameter. This formatting reverses the zero suppression that is used to generate the symbol in the UPC specification.

FIS-0870 Industrial Raster Scanner User’s Manual

5-85

Page 153

Symbologies

Code 93 Used in some clinical applications. Code 93 is a variable-length, continuous symbology employing four element widths. Each Code 93 character has nine modules that may be either black or white. Each character contains three bars and three spaces.

Fixed Symbol Length Status When disabled, the scanner will accept any Code 93 symbol provided is doesn’t exceed the system’s maximum capabilities. When enabled, the scanner will reject any Code 93 symbol that doesn’t match the fixed symbol length.

Fixed Symbol Length This is the symbol length value against which all Code 93 symbols will be compared.

5-86

FIS-0870 Industrial Raster Scanner User’s Manual

Page 154

Scanner Parameters

Pharmacode Used mostly in pharmaceutical packaging. Encodes up to five different numbers, each with its own color, which may be entered in decimal or “binary” format with a 1 represented by a thick bar and a 0 represented by a thin bar. Bar width is independent of height. In decimal format, each part can be up to 999,999. In binary format, each input can have up to 19 ones and zeros.

Important: When Pharmacode is enabled, other linear symbologies will not decode properly. Disable Pharmacode before reading other linear symbologies.

Fixed Symbol Length Status When enabled, the scanner will check the symbol length against the symbol length field. If disabled, any length will be considered valid.

Fixed Symbol Length Specifies the exact number of bars that must be present for the scanner to recognize and decode the Pharmacode symbol.

Minimum Bars Sets the minimum number of bars that a Pharmacode symbol must have to be considered valid.

Note: The minimum allowed bar count is 4.

FIS-0870 Industrial Raster Scanner User’s Manual

5-87

Page 155

Symbologies

Bar Width Status If set to Mixed, the scanner will autodiscriminate between narrow bars and wide bars. If set to All Narrow, all bars will be considered as narrow bars. If set to All Wide, all bars will be considered as wide bars. If set to Fixed Threshold, it will use the fixed threshold value to determine whether the bars are narrow or wide. The Bar Width Status setting will be ignored when the scanner is able to tell the difference between the narrow and the wide bars.

Direction Specifies the direction in which a symbol can be read.

Fixed Threshold Value Used when Bar Width Status is set to Fixed Threshold. Defines the minimum difference in pixels that will distinguish a narrow bar from a wide bar.

5-88

FIS-0870 Industrial Raster Scanner User’s Manual

Page 156

Scanner Parameters

GS1 DataBar Note: GS1 DataBar symbologies were previously known as “Reduced Space Symbology” or “RSS”.

DataBar Expanded Note: DataBar Expanded was previously known as “RSS Expanded”. Used to encode primary and supplementary data in retail point-of-sale and other applications. DataBar Expanded is a variable length symbology that can encode supplementary information in addition to the 14-digit EAN item identification number and is capable of encoding up to 74 numeric or 41 alphabetic characters. Where appropriate, use 1 (non-stacked) for better performance over 2 (stacked and non-stacked).

Fixed Symbol Length Status When enabled, the scanner will check the symbol length against the symbol length field, minus the embedded check character. If disabled, any length would be considered valid.

Fixed Symbol Length Fixed Symbol Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. Specifies the exact number of characters that the scanner will recognize (this does not include start, stop, and check character characters). The scanner ignores any symbol not having the specified length.

FIS-0870 Industrial Raster Scanner User’s Manual

5-89

Page 157

Symbologies

DataBar Limited Note: DataBar Limited was previously known as “RSS Limited”. DataBar Limited is designed to be read by laser scanners and CCD imagers. It is not recommended for omnidirectional slot scanners. Encodes a smaller 14-digit symbol (74 modules wide) that is not omnidirectional.

DataBar Omnidirectional Note: DataBar Omnidirectional was previously known as “RSS-14”. Used in the grocery, retail, and prescription drug industries where 14-digit EAN item identification may be needed. DataBar-14 is a fixed symbol length symbology that encodes 14 digits, including a 1-digit indicator. DataBar-14 is 96 modules wide. It can be stacked in two rows, it can read omnidirectionally if printed in full height, or horizontally if height-truncated for small marking. Note: Where appropriate, use 1 (non-stacked) for better performance instead of 2 (stacked; decode both stacked and non-stacked).