FIS-0870 Industrial Sweep Raster Scanner User's Manual: Scanner Parameters, pages 118 to 127

Pages 118 to 127 of 381, from FIS-0870 Industrial Sweep Raster Scanner User's Manual

The original document is the PDF (4.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Wenglor FIS-0870

Page 118

Scanner Parameters

Decodes Before Output Decodes Before Output specifies the number of times a symbol needs to be decoded to qualify as a good read.

Decodes Before Output Mode

Non-Consecutive In Non-Consecutive mode, decodes will be counted in any order. Multiple symbols can be decoded in any order.

Consecutive In Consecutive mode, all decodes must be identical until the good read count is satisfied. Only one unique symbol can be qualified at a time.

Number Before Output The number of successful decodes performed by the scanner before symbol data is output.

FIS-0870 Industrial Raster Scanner User’s Manual

5-51

Page 119

Read Cycle

End of Read Cycle The read cycle is the time during which the scanner will attempt to decode a symbol. A read cycle can be ended by a timeout or a new trigger, or a combination of the two.

End of Read Cycle Mode Note: When operating in Continuous Read or Continuous Read 1 Output, the scanner is always in the read cycle.

Timeout Typically used with Continuous Read 1 Output and Serial Data and Edge. It is effective in highly controlled applications when the maximum length of time between objects can be predicted. It assures that a read cycle ends before the next symbol appears, giving the system extra time to decode and transmit the data to the host. Timeout ends the read cycle, causing the scanner to stop reading symbols and send the symbol data or No Read message when the time set in Timeout elapses (times out), if When to Output Symbol Data is set to End of Read Cycle. If in Continuous Read 1 Output, a timeout initiates a new read cycle and allows the same symbol to be read again. With External Edge, Serial Data, or Serial Data and Edge enabled, a timeout ends the read cycle and symbol data or a No Read message is sent to the host. With External Level enabled, the read cycle does not end until the falling edge trigger occurs or a timeout occurs. The next read cycle does not begin until the next rising edge trigger.

5-52

FIS-0870 Industrial Raster Scanner User’s Manual

Page 120

Scanner Parameters

New Trigger New Trigger is an effective way to end a read cycle when objects move past the scanner at irregular intervals (not timing-dependent). New Trigger ends the current read cycle and initiates a new one when a new trigger occurs. New Trigger refers only to a rising edge trigger. With External Edge, Serial Data, or Serial Data and Edge enabled, an edge or serial trigger ends a read cycle and initiates the next read cycle. In the case of External Level, a falling edge trigger ends the read cycle but the next read cycle does not begin until the occurrence of the next rising edge trigger.

Timeout or New Trigger Useful in applications that require an alternative way to end the read cycle. For example, if an assembly line should stop completely or the intervals between objects are highly irregular. Timeout or New Trigger is identical to Timeout except that a timeout or a new trigger (whichever occurs first) ends the read cycle.

Last Frame Useful in applications in which the timeout duration varies.

Last Frame or New Trigger Useful in applications in which line speeds are irregular and a new object could appear before the last frame in the sequence. Last Frame or New Trigger is identical to New Trigger except that a new trigger or last frame (whichever occurs first) ends the read cycle.

FIS-0870 Industrial Raster Scanner User’s Manual

5-53

Page 121

Read Cycle

Read Cycle Timeout Read Cycle Timeout determines the duration of the read cycle.

5-54

FIS-0870 Industrial Raster Scanner User’s Manual

Page 122

Scanner Parameters

Processing Timeout Useful in higher speed applications with long processing times.

Note: If a timeout occurs during processing and no symbols in the field of view have been decoded, the result will be a No Read. For this reason, a longer timeout should be tried to ensure that the symbol is decoded successfully.

FIS-0870 Industrial Raster Scanner User’s Manual

5-55

Page 123

Read Cycle

Reader Setup Reader Setup parameters allow the user to configure Gain Level, Tracking, and Scan Speed parameters, as well as various Automatic Gain Control parameters.

Gain Level Gain Level can be used in two different ways, depending on the AGC Sampling Mode. When AGC Sampling Mode is set to Disabled: Gain Level is used as a “Fixed Gain”. The analog signal is amplified by this gain value. For Fixed Gain operation, changes to gain adjustment setting should be performed in Auto Calibration. When AGC Sampling Mode is set to Leading Edge or Continuous: Gain Level defines the “set point” analog signal level. The AGC system will attempt to hold the analog signal at this level by automatically raising and lowering the gain as needed.

5-56

FIS-0870 Industrial Raster Scanner User’s Manual

Page 124

Scanner Parameters

Tracking Useful in fine-tuning tracking or when conditions of poor contrast or blurred bar edges exist. Tracks peak signals and selects an amplitude reference point to sample the analog signals for converting to digital. Note: Tracking is optimized at the factory before shipment; in some cases the default value might not be 40.

Scan Speed Allows the user to set the number of scans per second by controlling the motor speed of the spinning mirror in the scanner.

FIS-0870 Industrial Raster Scanner User’s Manual

5-57

Page 125

Read Cycle

Automatic Gain Control AGC Sampling Mode Disabled (Fixed Gain) When AGC Sampling Mode is Disabled, the first parameter in the Gain Level command defines the Fixed Gain used to amplify the analog signal. In most applications, when changing the sampling mode to Disabled, the Gain Level will need to be changed. For Fixed Gain operation, changes to gain adjustment settings can be performed in Auto Calibration. Leading Edge Leading Edge uses only the first signal sample to calculate gain adjustments. The Transition Counter value is used to determine which transition triggers the sample. Important: This option should only be used if recommended by a Wenglor Sales or Applications representative, as the other AGC modes cover most application requirements. Continuous Continuous will take the highest value among any samples within a scan and use that value to make adjustments.

5-58

FIS-0870 Industrial Raster Scanner User’s Manual

Page 126

Scanner Parameters

AGC Minimum Sets a gain limit that AGC cannot go below when not in Fixed Gain operation.

AGC Maximum Sets a gain limit that AGC cannot exceed when not in Fixed Gain operation.

FIS-0870 Industrial Raster Scanner User’s Manual

5-59

Page 127

Read Cycle

Symbol Detect Status When Symbol Detect Status is enabled, Bad Symbol/No Symbol is output depending on whether or not there were enough transition counts, rather than based on a simple No Read. Note: Symbol detection can only be used when AGC Sampling Mode is set to Disabled (Fixed Gain).

Transition Counter Number of bar/space transitions required for an AGC sample. When multiple samples take place within a scan, the largest value is used. If symbol detection is enabled, the transition counter defines the minimum number of transitions required for a scan to qualify as a No Symbol (number of transitions < transition counter), or Bad Symbol (number of transitions > or = transition counter and no decode).

5-60

FIS-0870 Industrial Raster Scanner User’s Manual