Page 98

Scanner Parameters

Half Duplex Mode When Half Duplex Mode is enabled, the following conditions apply: Symbol Data to Source = Fixed to Enabled Ambles to Source = Fixed to Enabled Echo to Source = Fixed to Disabled Output at End of Read Cycle = Fixed to Disabled Output at ETX = Fixed to Disabled with user-defined characters. Default character will be used if this setting is set to Disabled. Output at Timeout = Fixed to Disabled with user-defined timeout. Default time will be used if this setting is set to Disabled. Mode of Operation • Source Port data is not echoed back to itself. • Source Port data is ignored when the Destination Port is in Polling Mode. • Source Port data or symbol data is sent to the Destination Port whenever it is received. • Source Port data is sent to the Destination Port without a Preamble or Postamble. • Symbol data is sent to the Source Port and the Destination Port at the same time, and conforms to the communication parameters. • Destination Port data is echoed to the Source Port in an un-polled mode.

FIS-0870 Industrial Raster Scanner User’s Manual

5-31

Page 99

Communication

Full Duplex Mode When Full Duplex Mode is enabled, the following conditions apply: Symbol Data to Source = Fixed to Disabled Ambles to Source = Fixed to Disabled Echo to Source = Fixed to Disabled Output at End of Read Cycle = Fixed to Disabled Output at ETX = Fixed to Disabled with user-defined characters. Default character will be used if this setting is set to Disabled. Output at Timeout = Fixed to Disabled with user-defined timeout. Default time will be used if this setting is set to Disabled. Mode of Operation • Source Port data is not echoed back to itself. • Source Port data is ignored when the Destination Port is in Polling Mode. • Source Port data or symbol data is sent to the Destination Port whenever it is received. • Source Port data is always sent to the Destination Port without a Preamble or Postamble. • Symbol data is not sent to the Source Port. • Destination port data is echoed to the source port in an un-polled mode.

Custom Mode Custom allows for user-defined communication (Ambles to Source, Echo to Source, Output at End of Read Cycle, Output at ETX, Output at Timeout).

5-32

FIS-0870 Industrial Raster Scanner User’s Manual

Page 100

Scanner Parameters

Destination Port Determines the port to which data will be sent.

Ambles to Source Enables or Disables the ability to send Preambles and Postambles to the Source port.

Echo to Source Enables or Disables the ability to send an Echo to the Source port.

Output at End of Read Cycle Enables or Disables the ability to output data at the end of read cycle.

FIS-0870 Industrial Raster Scanner User’s Manual

5-33

Page 101

Communication

Output at ETX Determines the output at ETX.

Output at Timeout Determines the Timeout value for output.

5-34

FIS-0870 Industrial Raster Scanner User’s Manual

Page 102

Scanner Parameters

Array Communication Modes

Mode Daisy Chain When set to Daisy Chain, follows Wenglor Daisy Chain protocol. Note: Daisy Chain can also be autoconfigured by sending the Daisy Chain Autoconfigure serial command.

Source Defines the communication port.

Daisy Chain ID Status When enabled, the scanner will append a two-character prefix to each scanner in the array. This allows the user to identify which scanner sent the data. Note: Daisy Chain ID will automatically disable Symbol Data Output, Extra Symbol Information, and Diagnostics Output for the Source Port. Symbol Data Output will be automatically enabled, Extra Symbol Information will be automatically enabled, and Diagnostics Output will be automatically disabled for the Destination Port.

FIS-0870 Industrial Raster Scanner User’s Manual

5-35

Page 103

Communication

Daisy Chain ID The Daisy Chain ID is a two-character identifier.

5-36

FIS-0870 Industrial Raster Scanner User’s Manual

Page 104

Scanner Parameters

Daisy Chain Autoconfigure For quick setup of a daisy chain configuration. The command to Autoconfigure the daisy chain is sent to the primary scanner and the software responds in the following ways: • Counts the number of secondary scanners in the daisy chain. • Assigns an internal ID number (1...n) to each secondary scanner, where the first secondary scanner is number 1 (the primary scanner’s ID being a 0). • Propagates the communication settings and the relevant operating modes of the primary scanner to the ports of each secondary scanner. • Resets each secondary scanner. • Confirms that each secondary scanner has acquired the new settings. When setting up a daisy chain operation, perform the following steps: • Set the primary scanner (the one connected to the host) to Serial Data Trigger Mode. This sets all the scanners in the chain to Serial Data when the command is executed. Important: All secondary scanners must be set to Serial Data Trigger Mode for Daisy Chain to function. Before Autoconfigure, the primary scanner must be set to Serial (S): Host

S

Primary Scanner

S

Secondary Scanner

S

Secondary Scanner

• Send the <K150DAISY> command from ESP’s Terminal. • If necessary, set the primary scanner to External Edge. After Autoconfigure, the primary scanner can be set to External Edge (E), but the other scanners must remain in Serial (S): Host

E

Primary Scanner

S

Secondary Scanner

S

Secondary Scanner

Important: If the scanner is Ethernet-enabled, first check to determine if RS-232 B is available. If it is available, set RS-232 B as the Source port in Array Communication Modes. Otherwise, set RS-232 A as the Source port. Port Routing for Symbol Data Output and Extra Symbol Information will be disabled on the Source port.

FIS-0870 Industrial Raster Scanner User’s Manual

5-37

Page 105

Communication

Preamble Useful for identifying and controlling incoming data. For example, defining the preamble as a carriage return and a line feed causes each decoded message to be displayed on its own line.

Preamble Characters Allows the user to define up to four postamble characters that can be added to the end of the decoded data

5-38

FIS-0870 Industrial Raster Scanner User’s Manual

Page 106

Scanner Parameters

Postamble Useful for identifying and controlling incoming data. For example, defining the postamble as a carriage return and a line feed causes each decoded message to be displayed on its own line.

Postamble Characters Allows the user to define up to four postamble characters that can be added to the end of the decoded data.

FIS-0870 Industrial Raster Scanner User’s Manual

5-39

Page 107

Read Cycle

Read Cycle Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Read Cycle tab to display the Read Cycle tree control.

The * indicates that the setting is the default.

To open nested options, single-click the +.

To change a setting, double-click the setting and use the cursor to scroll through the options.

Note: Read Cycle settings can also be sent to the scanner from ESP’s Terminal using Wenglor’s K command format. Refer to Read Cycle.

5-40