Page 31

Setup & Configuration, MSI Plessey MSI Plessey is a variable length numeric symbology and is primarily used in marking retail shelves. Each character consists of four bars with intervening spaces for each encoded digit, one or two symbol check digits, and a reverse start code. NOTE: For help in configuring these settings, consult the programming steps on page 5.

Option

Alpha/Numeric Entry (Back Flap)

Disable Enable

00* 01

Disable Mod 10 Mod 10/10 Mod 11/10

00* 01 02 03

Disable Enable

00* 01

64 - Minimum

64 - 00 00*

00 - Maximum

00 - 64 00*

Begin

On/Off

Verify Check Digit

Transmit Check Digit

Set Maximum Length

Set Minimum Length

Exit

28 Downloaded from www.Manualslib.com manuals search engine

*Default

Page 32

Setup & Configuration, PDF417 PDF417 is a 2D variable length symbology that can encode virtually any letter, number, or character. Each character consists of 4 bars and 4 spaces in a 17 module structure. The name of the symbol is derived from the format of the code. PDF stands for "Portable Data File" and "417" is derived from the module structure. Each PDF417 symbol consists of 3 to 90 stacked rows surrounded by a quiet zone on all four sides. Each row consists of a leading quiet zone, start pattern, left row indicator character, one to thirty data characters, right row indicator character, stop pattern, and trailing quiet zone. PDF417 supports text compaction, numeric compaction, and byte compaction that correlate the mapping between code word values and decoded data. PDF417 can accommodate up to 340 characters per square inch with a maximum data capacity of 1850 text characters. NOTE: For help in configuring these settings, consult the programming steps on page 5.

Begin

Option

Alpha/Numeric Entry (Back Flap)

Disable Enable

00* 01

On/Off

Exit

29 Downloaded from www.Manualslib.com manuals search engine

*Default

Page 33

Setup & Configuration, Bar Code Test Symbols - Appendix A Note: Make sure that the appropriate bar code symbology is configured properly and enabled before trying to scan. Use the 'Bar Code Symbologies' configuration beginning on page 14 to enable specific symbologies.

Code 39*

Code 93*

Interleaved 2 of 5

Codabar*

Code 128*

MSI/Plessey

30 Downloaded from www.Manualslib.com manuals search engine

*Default

Page 34

Setup & Configuration, Bar Code Test Symbols - Appendix A (cont.)

UPC-A*

UPC-A w/5 digit supplement

UPC-A w/2 digit supplement

UPC-E*

UPC-E w/5 digit supplement

UPC-E w/2 digit supplement

31 Downloaded from www.Manualslib.com manuals search engine

*Default

Page 35

Setup & Configuration, Bar Code Test Symbols - Appendix A (cont.)

EAN/JAN 13*

EAN/JAN 13 w/5 digit supplement

EAN/JAN 13 w/2 digit supplement

3 Downloaded from www.Manualslib.com manuals search engine

*Default

Page 36

Setup & Configuration, Bar Code Test Symbols - Appendix A (cont.)

EAN/JAN 8*

EAN/JAN 8+5 w/5 digit supplement

EAN/JAN 8 w/2 digit supplement

PDF417

33 Downloaded from www.Manualslib.com manuals search engine

*Default

Page 37

Setup & Configuration, WLP 4170 CCD Specifications MODEL

WLP 4170

OPTICAL Scanning Width

3.2 in (120 mil)

Depth of Field

0 to 3 in (0 to 200 mil)

Scan Rate

200 scans / second

ELECTRICAL Light Source

660 nm red visible LED

Sensor

2,048 pixel CCD array

Operating Voltage

+5 VDC ± 0.25V

Current Consumption

Standby 100 mA @ 5 VDC / Sleep 25 mA @ 5 VDC Operating 180 mA @ 5 VDC

MECHANICAL Dimensions

W3.5" x T4.5" x H7.2"

Weight

150 g (without cable)

Cable

6 ft

ENVIRONMENTAL Operating Temperature

0˚C to 40˚C

Storage Temperature

-40˚C to 60˚C

Relative Humidity

5% to 90% non-condensing

Safety Certification

Conforms FCC Class A and CE requirements

OUTER DIMENSIONS

34 Downloaded from www.Manualslib.com manuals search engine

Page 38

Product Support If you experience any problems with Wasp WLP 4170 CCD Scanner that you are unable to resolve, call for technical assistance at (214) 547-4100, Monday through Friday, 8:00 AM - 5:00 PM Central Standard Time. Our web site is www.waspbarcode.com You may also contact us in writing at: Wasp Technologies 1400 10th Street Plano, TX 75074 (214) 547-4100 (214) 547-4101 Fax

Warranty Information Wasp Bar Code products are warranted against defects in workmanship and materials for a period of one year from the date of shipment, provided that the product remains unmodified and is operated under normal and proper conditions. This warranty is limited to repair or replacement at Wasp Bar Code's option, with reasonable promptness after being notified. These provisions do not prolong the original warranty term for any product which has been repaired or replaced by Wasp Bar Code. This warranty applies to the original owner and does not extend to any product which has been subject to misuse, neglect, accidental damage, unauthorized repair, or tampering. No other express warranty is given. The replacement or repair of a product is your exclusive remedy. Any other implied warranty of merchantability or fitness is limited to the duration of this written warranty. Some states, provinces, and countries do not allow how long an implied warranty lasts, so the above limitation may not apply to you. In no event shall Wasp Bar Code be liable for consequential damages. Some states, provinces, and countries do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations may not apply to you.

35 Downloaded from www.Manualslib.com manuals search engine

Page 39

ASCII Code Table ASCII Preamble/Postamble Code Table Code ASCII Code ASCII Code ASCII Code ASCII 00 01 02 03 04 05 06 08 09 0B 0C 0D 0E 0F 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 20 21 22

Null Up Down Left Right PgUp PgDn BS Tab Home End Enter Insert Delete F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 ESC F11 F12 Ctrl+ Alt+ Space ! “

23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 40 41 42

# $ % & ‘ ( ) ★ +

43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F 60 61 62

. / 0 1 2 3 4 5 6 7 8 9 : ; < = > ? @ A B

36 Downloaded from www.Manualslib.com manuals search engine

C D E F G H I J K L M N O P Q R S T U V W X Y Z [ ] ^ _ ` a b

63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F c d e f g h i j k l m n o p q r s t u v w x y z

~ Delete

Page 40 read from a scan by OCR; it may hold reading errors

MTL 0 A 1 VAN 2 WAV 3 ATA 4 WAV 5 WAV 6 A 7 AU 8 WAV 9

Downloaded from www.Manualslib.com manuals search engine

MTT A MTT B IMT C MTN D IMT E IMM F IMT

FINISH

BACK COVER BAR CODES