Page 25

CCD Setup & Configuration, Bar Code Test Symbols - Appendix A (cont.)

EAN/JAN 13 (Default: Enabled)

EAN/JAN 13 5 digit supplement (Default: Disabled)

EAN/JAN 13 2 digit supplement (Default: Disabled)

EAN/JAN 8 (Default: Enabled)

EAN/JAN 8 5 digit supplement (Default: Disabled)

EAN/JAN 8 2 digit supplement (Default: Disabled)

22

Page 26

CCD Setup & Configuration, Preamble/Postamble Addition Table - Appendix B

Use this table to add preamble and postamble characters to your bar code value. Make sure that you scan the two bar codes associated with each ASCII character on page 25 before preceding to the next character. Up to seven ASCII characters can be added. Scan the 'Set' option when you are finished. For example, to add a Right Brace and a Tab as a preamble: • Scan 'Begin' and 'Preamble' on page 7 • Scan '7' and 'D' on page 25 for the right brace • Scan '8' and '9' on page 25 for the Tab • Scan 'Set' on page 7 to terminate the addition of preamble characters • Scan 'End' on page 7 to complete the preamble addition

Preamble/Postamble Addition Table Code ASCII Code ASCII Code ASCII Code ASCII 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15

INS DEL Home End Up Down Left BS HT LF Right PgUp Enter PgDn F1 F2 F3 F4 F5 F6 F7

16 17 18 19 1A 1B 1C 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D

F8 F9 F10 F11 F12 ESC Exec Space ! " # $ % & ' ( ) * + , -

2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 40 41 42

23

. / 0 1 2 3 4 5 6 7 8 9 : ; < = > ? @ A B

43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 cont. on next page

C D E F G H I J K L M N O P Q R S T U V W

Page 27

CCD Setup & Configuration, Preamble/Postamble Addition - Appendix B (cont.) Preamble/Postamble Addition Table (cont.) Code ASCII Code ASCII Code ASCII 58 59 5A 5B 5C 5D 5E 5F 60 61 62 63 64 65 66 67 68 69 6A

X Y Z [ \ ] ^ _ ` a b c d e f g h i j

6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D k l m n o p q r s t u v w x y z { | }

*Enter Key of the numeric keypad

24

7E 7F 8F

~ Null Enter*

Page 28

CCD Setup & Configuration, Preamble/Postamble Addition - Appendix B (cont.)

0

8

1

9

2

A

3

B

4

C

5

D

6

E

7

F

25

Page 29

CCD Setup & Configuration, Preamble/Postamble Addition - Special Characters

Use these barcodes to add special preamble and postamble characters to your bar code value. For example, to add a Control, Function 1 as a postamble: • Scan 'Begin' and 'Postamble' on page 7 • Scan 'Add Right Control' on page 26 • Scan '0' and 'F' on page 25 for the Function 1 • Scan 'Set' on page 7 to terminate the addition of postamble characters • Scan 'End' on page 7 to complete the postamble addition

Add Shift

Add Right Control

Add Left Control

Add Right ALT

Add Left ALT

26

Page 30

CCD Setup & Configuration, Additional Scanner Functions - Appendix C

Your Wasp Bar Code CCD Scanner can perform additional functions, such as: 1. Negative image bar code scanning 2. Code identification 3. Advanced data editing Call our support department for more details and programming materials if you need to use these functions. Contact us at 214-547-4100.

27

Page 31

Product Support If you experience any problems with Wasp CCD that you are unable to resolve, call for technical assistance at (214) 547-4100, Monday through Friday, 8:00 AM - 5:00 PM U.S. Central Standard Time. Also, please consult our FAQ (Frequently Asked Questions) section on our web site at www.waspbarcode.com You may also contact us in writing at: Wasp Technologies 1400 10th Street Plano, TX 75074 (214) 547-4100 (214) 547-4101 Fax

Warranty Information Wasp Technologies products are warranted against defects in workmanship and materials for a period of one year from the date of shipment, provided that the product remains unmodified and is operated under normal and proper conditions. This warranty is limited to repair or replacement at Wasp Technologies option, with reasonable promptness after being notified. These provisions do not extend the original warranty term for any product which has been repaired or replaced by Wasp Technologies. This warranty applies to the original owner and does NOT extend to any product which has been subject to misuse, neglect, accidental damage, unauthorized repair, or tampering. No other express warranty is given.The replacement or repair of a product is your exclusive remedy. Any other implied warranty of merchantability or fitness is limited to the duration of this written warranty. Some states, provinces, and countries do not allow limitations on the duration of an implied warranty, so the above limitation may not apply to you. In no event shall Wasp Technologies be liable for consequential damages. Some states, provinces, and countries do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations may not apply to you.

28