The text of a manual · part 24 of 25
TimeWand II Communications & Application Builder for DOS Computers, pages 231 to 240
Pages 231 to 240 of 248
The original document is the PDF (828 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Videx TimeWand II
Page 231
Problem 5: Blank Display The TimeWand II stops working and the display goes blank. The wand will not respond to any keypress. Cause: The battery voltage is too low or the signal flow has been interrupted. Solution: 1. Reset the unit. TimeWand II should beep three times. 2. Verify that it is in Monitor Mode. 3. Place the TimeWand II in a recharger/downloader and leave it in for at least 16 hours. Verify that it is charging by pressing the scan button. If it is charging, the bottom line of the display shows CHG. The battery charges at its standard charge rate for 16 hours and then automatically drops to a trickle charge. 4. At the end of the 16-hour initial charge time, program the TimeWand II. 5. After the TimeWand II is programmed, its display will show 51% charge left. If the problem re-occurs, the unit should be returned to Videx for further evaluation and repair. Contact the Videx Technical Support Department for assistance.
Appendix H TimeWand II NiCad Battery Notes
227
Page 232
Notes:
228
Appendix H TimeWand II NiCad Battery Notes
Page 233
Appendix I TimeWand II Specifications
Contents P. 220 TimeWand II Specifications P. 221 Bar Code Specifications P. 222 TimeWand II Recharger/Downloader Station
Appendix I TimeWand II Specifications
229
Page 234
TimeWand II Specifications Physical: Dimensions: Weight:
Rugged, cast-metal case 4.1" x 2.6" x 0.6" (104 x 66 x 15 mm) 4.9 oz (139 g)
Storage Temperature:
-4° to 122° F (-20° to 50° C)
Operating Temperature:
32° to 122° F (0° to 50° C)
Humidity:
0 to 95% non condensing
Keypad:
19 operational keys; numeric or alphanumeric
Charging Time:
230
12-15 hours for fully drained batteries
Memory:
64K, 128K, or 320K RAM
Display:
2-line x 16-character liquid crystal display (LCD); 5 x 7 dot matrix displays 96 standard ASCII characters
Audio:
14 tone patterns including good read and key entry
Optics:
Special optical circuitry allows scanning in complete darkness or direct sunlight; 700 nm near-visible light optics is standard; 820 nm infrared and 655 nm visible optics are optional; read head is enclosed In a protective sapphire tip shield
Battery:
Rechargeable nickel-cadmium (NiCad) replaceable battery pack
Appendix I TimeWand II Specifications
Page 235
Battery Life:
Provides up to 3 days charge, depending upon use; life expectancy of battery pack is 2 years or 500 full charge-discharge cycles
Serial Communications:
Packetized for error correction; built-in asynchronous RS-232 serial port, baud rates from 300 to 19.2K
Clock:
Real-time; time and date stamps each successful bar code scan
Optional LED Scan Light
Provides LED flash after successful scan; LED is installed in TimeWand II serial port
Bar Code Specifications Scanning Speed:
3 to 30 inches per second
Resolution:
Minimum 0.0075" width of narrow bar or space (0.01" recommended)
Bar Code Symbologies:
Code 3 of 9, Interleaved 2 of 5, Codabar, Code 128, UPC, and EAN
Appendix I TimeWand II Specifications
231
Page 236
TimeWand II Recharger/Downloader Station Size:
Single station - 4.0" x 4.0" x 1.5" (102 x 102 x 38 mm) Multiple station - 8.6" x 4.0" x 1.5" (218 x 102 x 38 mm)
Weight:
Single station - 7.3 oz (207 g) Multiple station - 14.7 oz (420 g)
Number of Wands:
Single station - 1 wand Multiple station - 4 wands
Power Supply Adapters:
120 volt (60 Hz) Input: 120 VAC, 60 Hz, 7W Output: 12 VDC, 300 mA Plug Polarity:
_
+
220 volt (50 Hz) Input: 220 VAC, 50 Hz, 9W Output: 12 VDC, 300 mA, 3.6 VA Plug Polarity:
+
Indicator Lights:
Power, Transmit, and Receive
Connection Ports:
Single station - Computer, Power Multiple station - Computer, Extension, and Power
Serial Communications:
232
_
Standard RS232
Appendix I TimeWand II Specifications
Page 237
Appendix J
Sample Applications Bar Codes
Contents P. 224 Inventory Application P. 226 Retail Application P. 228 Security Application
Appendix J Sample Applications Bar Codes
233
Page 238
Inventory Application (INVENTRY.APX) The following bar codes can be used with the INVENTRY.APX sample application. Warehouse Bar Codes
*E123*
*D456*
*FXX*
*93EBR*
Bin # Bar Codes
*ED123*
*DD456*
*FG235*
*NM931*
Item # Bar Codes
*E0002*
Resistor 1K Ohm
*E0003*
32K CMOS RAM
*E0012*
Capacitor 0.1 mf
234
Appendix J Sample Applications Bar Codes
Page 239
Quantity Bar Codes
*
*1*
*2*
*3*
*4*
*5*
*6*
*7*
*8*
*9*
*0*
*
*
Enter
Clear
*
Appendix J Sample Applications Bar Codes
235
Page 240
Retail Application (RETAIL.APX) The following bar codes can be used with the RETAIL.APX sample application. Customer Bar Codes
*C12*
*C34*
*C56*
*C78*
Item # Bar Codes
*TW008*
8K TimeWand
*TW016*
16K TimeWand
*TWR000*
Rechg/Downloader
*TWR002*
Multi-Control
*TWR003*
Multi Add-on
236