Problem 5: Blank Display The TimeWand II stops working and the display goes blank. The wand will not respond to any keypress. Cause: The battery voltage is too low or the signal flow has been interrupted. Solution: 1. Reset the unit. TimeWand II should beep three times. 2. Verify that it is in Monitor Mode. 3. Place the TimeWand II in a recharger/downloader and leave it in for at least 16 hours. Verify that it is charging by pressing the scan button. If it is charging, the bottom line of the display shows CHG. The battery charges at its standard charge rate for 16 hours and then automatically drops to a trickle charge. 4. At the end of the 16-hour initial charge time, program the TimeWand II. 5. After the TimeWand II is programmed, its display will show 51% charge left. If the problem re-occurs, the unit should be returned to Videx for further evaluation and repair. Contact the Videx Technical Support Department for assistance.

Appendix H TimeWand II NiCad Battery Notes

227

Page 232

Notes:

228

Appendix H TimeWand II NiCad Battery Notes

Page 233

Appendix I TimeWand II Specifications

Contents P. 220 TimeWand II Specifications P. 221 Bar Code Specifications P. 222 TimeWand II Recharger/Downloader Station

Appendix I TimeWand II Specifications

229

Page 234

TimeWand II Specifications Physical: Dimensions: Weight:

Rugged, cast-metal case 4.1" x 2.6" x 0.6" (104 x 66 x 15 mm) 4.9 oz (139 g)

Storage Temperature:

-4° to 122° F (-20° to 50° C)

Operating Temperature:

32° to 122° F (0° to 50° C)

Humidity:

0 to 95% non condensing

Keypad:

19 operational keys; numeric or alphanumeric

Charging Time:

230

12-15 hours for fully drained batteries

Memory:

64K, 128K, or 320K RAM

Display:

2-line x 16-character liquid crystal display (LCD); 5 x 7 dot matrix displays 96 standard ASCII characters

Audio:

14 tone patterns including good read and key entry

Optics:

Special optical circuitry allows scanning in complete darkness or direct sunlight; 700 nm near-visible light optics is standard; 820 nm infrared and 655 nm visible optics are optional; read head is enclosed In a protective sapphire tip shield

Battery:

Rechargeable nickel-cadmium (NiCad) replaceable battery pack

Appendix I TimeWand II Specifications

Page 235

Battery Life:

Provides up to 3 days charge, depending upon use; life expectancy of battery pack is 2 years or 500 full charge-discharge cycles

Serial Communications:

Packetized for error correction; built-in asynchronous RS-232 serial port, baud rates from 300 to 19.2K

Clock:

Real-time; time and date stamps each successful bar code scan

Optional LED Scan Light

Provides LED flash after successful scan; LED is installed in TimeWand II serial port

Bar Code Specifications Scanning Speed:

3 to 30 inches per second

Resolution:

Minimum 0.0075" width of narrow bar or space (0.01" recommended)

Bar Code Symbologies:

Code 3 of 9, Interleaved 2 of 5, Codabar, Code 128, UPC, and EAN

Appendix I TimeWand II Specifications

231

Page 236

TimeWand II Recharger/Downloader Station Size:

Single station - 4.0" x 4.0" x 1.5" (102 x 102 x 38 mm) Multiple station - 8.6" x 4.0" x 1.5" (218 x 102 x 38 mm)

Weight:

Single station - 7.3 oz (207 g) Multiple station - 14.7 oz (420 g)

Number of Wands:

Single station - 1 wand Multiple station - 4 wands

Power Supply Adapters:

120 volt (60 Hz) Input: 120 VAC, 60 Hz, 7W Output: 12 VDC, 300 mA Plug Polarity:

_

+

220 volt (50 Hz) Input: 220 VAC, 50 Hz, 9W Output: 12 VDC, 300 mA, 3.6 VA Plug Polarity:

+

Indicator Lights:

Power, Transmit, and Receive

Connection Ports:

Single station - Computer, Power Multiple station - Computer, Extension, and Power

Serial Communications:

232

_

Standard RS232

Appendix I TimeWand II Specifications

Page 237

Appendix J

Sample Applications Bar Codes

Contents P. 224 Inventory Application P. 226 Retail Application P. 228 Security Application

Appendix J Sample Applications Bar Codes

233

Page 238

Inventory Application (INVENTRY.APX) The following bar codes can be used with the INVENTRY.APX sample application. Warehouse Bar Codes

*E123*

*D456*

*FXX*

*93EBR*

Bin # Bar Codes

*ED123*

*DD456*

*FG235*

*NM931*

Item # Bar Codes

*E0002*

Resistor 1K Ohm

*E0003*

32K CMOS RAM

*E0012*

Capacitor 0.1 mf

234

Appendix J Sample Applications Bar Codes

Page 239

Quantity Bar Codes

*

*1*

*2*

*3*

*4*

*5*

*6*

*7*

*8*

*9*

*0*

*

*

Enter

Clear

*

Appendix J Sample Applications Bar Codes

235

Page 240

Retail Application (RETAIL.APX) The following bar codes can be used with the RETAIL.APX sample application. Customer Bar Codes

*C12*

*C34*

*C56*

*C78*

Item # Bar Codes

*TW008*

8K TimeWand

*TW016*

16K TimeWand

*TWR000*

Rechg/Downloader

*TWR002*

Multi-Control

*TWR003*

Multi Add-on

236