For the Videx TimeWand II

Page 211

Appendix E Explanation of CONVERT2.EXE Videx provides software tools with the TimeWand II Communications & Application Builder software which enable applications developers and programmers to incorporate the TimeWand II directly into applications. One of these software tools is CONVERT2.EXE. CONVERT2.EXE is an executable program which takes the raw scan file produced by the TimeWand II and converts it into a formatted ASCII text file, using the parameters the user specifies. CONVERT2.EXE can be run from the DOS prompt, from within a batch file, or from within your own application program. CONVERT2.EXE is run from the command line by entering the file name “CONVERT2” with certain parameters. These parameters are explained below: /s

Menu system which enables the user to specify the parameters to use in the convert process. Press <Esc> to exit the menu system. Note: Specifying a “Raw scan file” causes the TimeWand II raw scan file to be converted to a TimeWand I raw scan file.

<input file> <output file>

The input file is the TimeWand II raw scan file. The output file must not exist or CONVERT2 asks if it can be overwritten.

Example:

convert2 data.bcd data.txt

Appendix E Explanation of CONVERT2.EXE

207

Page 212

Notes:

208

Appendix E Explanation of CONVERT2.EXE

Page 213

Appendix F Modem Transfer Set Up Diagram The following illustration shows you how to connect the Recharger/Downloader Station to a modem for remote data transfer. Videx Recharger/Downloader Hayes-compatible 1200 baud modem. Remote modem cable TWC-003

Phone Line

IBM to Recharger/Downloader cable TWC-001 or TWC-008 Host Modem Cable TWC-002 Videx Recharger/Downloader

Hayes-compatible 1200 baud modem. - OR standard modem cable

Figure F-1 Modem Transfer Set Up

Appendix F Modem Transfer Set Up Diagram

209

Page 214

Notes:

210

Appendix F Modem Transfer Set Up Diagram

Page 215

Appendix G Automatic Recharge Management The TimeWand II software automatically controls the recharge cycle, allowing the batteries to recharge as quickly as possible without being overcharged. The TimeWand II estimates how much standard charge it requires by keeping track of the last time it was in the recharger/downloader and the amount of use it has received. You can view an estimation of the amount of charge left in a programmed TimeWand II and how much time is required to bring it to a full charge capacity by pressing the M and left arrow keys simultaneously. When the wand is placed in the recharger/ downloader, the batteries are charged at a standard-charge rate for the amount of time the wand has estimated the batteries require. While the TimeWand II is charging, the first line of the display gives information about the charge state of the battery (in percentage) and the second line displays how much time before full charge is reached. When the batteries are fully charged, the display flashes so that the end of the standard-charge cycle is easily noticed. After the standard charge period, the charge rate reduces to a trickle charge. The batteries are able to tolerate longer periods at this reduced rate and still maintain a fully-charged state. When a program is first loaded into a TimeWand II, the TimeWand II has no information about the true charge state of the batteries. Therefore, the standard charge time is set to an arbitrary initial value of 6.66 hours. This amount of time fully charges batteries that are 50% discharged. Even if the wand is actually fully charged when placed in the recharger/ downloader, an occasional overcharge of this amount causes no harm. The representation of the amount of charge remaining may be somewhat different than the actual charge state of the Appendix G Automatic Recharge Management

211

Page 216

batteries. Therefore the charge rate display should be used only as a guide. The system is designed with a bias toward giving a little more charge than actually required so that it is unlikely you will ever be left short on charge when the system says the batteries are full. As you become more familiar with how the charge rate display fits your use pattern, the information allows you to more accurately judge how often to recharge your wand.

Setting the Default Value for Charge Needed A utility is included with the TimeWand II Communications & Application Builder software that allows you to change the initial value of charge needed if the charge state of the batteries is known to be different from the default value of 6.66 hours. To set the charge-needed value, type the following command from the directory where the TimeWand II software is kept: SETCHG

You are prompted for the serial communications port number and the baud rate. Insert the wand into the recharger/ downloader and enter the number of hours to charge. You can set the charge rate for several wands without re-entering the port number or baud rate. However, you must only have one wand in the recharger/downloader at a time while setting the charge-needed rate. It is possible to set the charge-needed rate to different values for each wand; they will each charge according to their own setting when placed in the recharger/downloader for recharging. Videx can provide programming information to allow for the alteration of the charge status messages, such as a different language. Contact the Videx Technical Support Department for additional information.

212

Appendix G Automatic Recharge Management

Page 217

The display shows 100% Charge while in the recharger/downloader, but shows Low Power when removed from the recharger/downloader.

The estimate is based on time, NOT on the actual charge capacity of the batteries. If your batteries are at the end of their life, the charge status will display 100% charge, but show Low Power when removed from the recharger/ downloader. If this happens, replace the TimeWand II battery pack. The display showed 100% Charge, the wand was reset and reprogrammed, now it shows 50% Charge.

Each time the wand is reset all information is cleared from the wand, including the charge status. When a TimeWand II is programmed, the wand has no information about the true charge state of the batteries. Therefore, the amount of time to bring the batteries to a full charge is set to an arbitrary value of 7.0 hours. This amount of time fully charges batteries that are 50% discharged. So each time your wand is reset and reprogrammed the charge state starts at approximately 50%. Even if the batteries in your wand are fully charged, an occasional overcharge of this amount will not damage the batteries. See Appendix H for more information on TimeWand II batteries.

Appendix G Automatic Recharge Management

213

Page 218

Notes:

214

Appendix G Automatic Recharge Management

Page 219

Appendix H TimeWand II NiCad Battery Notes

Contents P. 206 P. 206 P. 208 P. 209 P. 210 P. 211 P. 213

Introduction Battery Terms Battery Discharge and Voltage Depression TimeWand II Terms TimeWand II Battery Specifications Correct Battery Charge Management Problems and Solutions

Appendix H TimeWand II NiCad Battery Notes

215

Page 220

TimeWand II NiCad Battery Notes Introduction The behavior of the NiCad battery affects the operation of the equipment it powers. The purpose of this appendix is to develop a better understanding of the unique characteristics of NiCad batteries by describing their effect on the TimeWand II. The following sections explain basic NiCad battery terms, TimeWand II terms, TimeWand II battery specifications, and correct battery charge management. The last section explores specific TimeWand II problems and their solutions.

Battery Terms Cell

The basic unit of the battery (e.g., car batteries have six cells, “AA“ or “C” batteries have one cell each).

Battery Capacity

The amount of charge available from a battery; usually measured in milliamperehours.

Operation Cutoff Voltage The voltage below which the equipment cannot function. (TimeWand II operation cutoff voltage is 4.3 volts.) Charge Rate

The rate at which current is input to the battery.

Charge-Discharge Cycle

When a battery is discharged to the cutoff voltage level and recharged to full capacity.

Trickle Charge

A battery charge current of less than 1/50th of its rated capacity. Measured in milliamperes.

Standard Charge

A battery charge current of 1/10th of its rated capacity. Measured in milliamperes.

216

Appendix H TimeWand II NiCad Battery Notes