Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 11 of 25

TimeWand II Communications & Application Builder for DOS Computers, pages 101 to 110

Pages 101 to 110 of 248

The original document is the PDF (828 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Videx TimeWand II

Page 101

9. Press <Enter>. The field name is entered in the Field Name column and the field is given a level number of 0.0 by default (Figure 3-14).

Figure 3-14 Create Application Screen - Field Added 10. Press <Enter> to edit the level number (Figure 3-15).

Figure 3-15 Edit Level Number

Chapter 3 TimeWand II Applications

97

Page 102

11. Type 1.0 (Figure 3-16).

Figure 3-16 Changing Level Number 12. Press <Enter> to save the edit (Figure 3-17). (Note: The Default column is filled because the first field in a level cannot have a default entry.)

Figure 3-17 Level Number Changed

98

Chapter 3 TimeWand II Applications

Page 103

13. To add the next field, press <F9> and type Location in the Add Field Name box (Figure 3-18).

Figure 3-18 Add Second Field 14. Press <Enter> to add the Location field (Figure 3-19). The field name is entered in the Field Name column and the field is given a level number of 0.0 by default.

Figure 3-19 Second Field Added

Chapter 3 TimeWand II Applications

99

Page 104

15. Press <Enter> to edit the level number (Figure 3-20).

Figure 3-20 Edit Level Number 16. Type 2.0 (Figure 3-21).

Figure 3-21 Changing Level Number

100

Chapter 3 TimeWand II Applications

Page 105

17. Press <Enter> to save the edit (Figure 3-22). (Note: This field’s Default column is also filled because the first field in a level cannot have a default entry.)

Figure 3-22 Level Number Changed 18. Press <F9> once more to enter the final field. Type Status in the Add Field Name box (Figure 3-23).

Figure 3-23 Add Last Field

Chapter 3 TimeWand II Applications

101

Page 106

19. Press <Enter> to add the Status field (Figure 3-24). The field name is entered in the Field Name column and the field is given a level number of 0.0 by default.

Figure 3-24 Last Field Added 20. Press <Enter> to edit the level number (Figure 3-25).

Figure 3-25 Edit Level Number

102

Chapter 3 TimeWand II Applications

Page 107

21. Type 2.1 (Figure 3-26).

Figure 3-26 Changing Level Number 22. Press <Enter> to save the edit (Figure 3-27). (Note: This field’s Default column is not automatically filled because it is not the first field in a level. This field can have a default entry.)

Figure 3-27 Level Number Changed

Chapter 3 TimeWand II Applications

103

Page 108

23. Press <F10> to sort the fields (Figure 3-28).

Figure 3-28 Fields Sorted 24. Use the arrow keys to move the cursor to the GUARD field’s Match Criteria column (Figure 3-29).

Figure 3-29 GUARD Field Match Criteria Column

104

Chapter 3 TimeWand II Applications

Page 109

25. Press <Enter> and the Match Criteria choices are displayed.

Figure 3-30 GUARD Match Criteria Choices Displayed

26. To select a Match Criteria choice, use the up and down arrow keys to select the criteria and press <Enter>. In this example we want the BEGINS WITH match criteria for this field, so you only need to press <Enter> when BEGINS WITH is highlighted. The GUARD dialog changes to Barcodes begin with: (Figure 3-31).

Figure 3-31 GUARD Field Begins With...

Chapter 3 TimeWand II Applications

105

Page 110

27. The bar codes we are using to identify the guards begin with the letter G. Type a G (Figure 3-32).

Figure 3-32 GUARD Field Begins With G

28. Press <Enter> and the software displays the match criteria as a pattern (Figure 3-33).

Figure 3-33 GUARD Field Match Criteria

106

Chapter 3 TimeWand II Applications