For the Videx DuraTrax and Videx LaserLite

Page 81

If a unit is awake and receives an unlock command with the wrong ID, it will stay awake as long as it detects activity on the serial port. By placing six unused IDs at the beginning of the IDs.txt file, it is possible to ensure that each unit receives at least one unlock command with an invalid ID and then stays awake. Then each unit is awake when the FOREACH loop attempts to unlock it and the unit is downloaded. The program only attempts to unlock each unit one time; if a unit is not present, the program moves on to the next ID. The program quits after attempting one time to unlock and download each unit. For complete information on using the commands file, see Chapter 1 of the Developer’s Reference manual.

Appendix E Using Multiple Data Collectors and Base Stations

73

Page 82

Notes on Using Multiple Data Collectors To avoid problems when using multiple data collectors and Base Stations, you need to be aware of the following cautions: •

Each data collector used in a multiple Base Station arrangement must have a unique ID. See the preceding section in this appendix for information on changing a data collector’s ID.

•

When the data transfer process begins, do not remove a data collector from its Base Station, quit the program, or shut down your computer until the transfer process is completed. Caution: Do not attempt to send an application to more than one data collector at a time in a multiple Base Station set up. The units will not be damaged, but they will not be properly programmed. When transferring data from data collectors, do not interrupt the process by removing the unit from its Base Station or aborting the program. The system is designed to avoid data loss, but observing this caution provides added protection.

If you should inadvertently remove a data collector while it is in the process of transferring data, the software displays a message that it was unable to communicate with the unit and then continues to try to transfer the data from all of the other data collectors. The data in the interrupted unit will not be cleared and can be transferred after the others have completed their data transfer. Key Points on Using Multiple Data Collectors

•

Each data collector must have a unique ID.

•

When sending files to a data collector, it must be the only unit in a Base Station.

•

Do not interrupt the data transfer process.

•

Data is not cleared from a data collector until all of the data is correctly transferred to the computer.

74

Appendix E Using Multiple Data Collectors and Base Stations

Page 83

Notes:

Appendix E Using Multiple Data Collectors and Base Stations

75

Page 84

Appendix F Resetting the DuraTrax/LaserLite In the unlikely event that your DuraTrax or LaserLite locks up and does not correct itself after sitting for 2 to 3 minutes, you will need to manually reset the unit to Monitor mode and resend the operating system software. To manually reset the unit to Monitor mode: 1) Remove the battery end cap. 2) Hold the scan button down while replacing the battery end cap. 3) The unit will beep three times, indicating a successful reset. 4) The unit will show VX1 Monitor 1.07 on the first line, and Ready, bps=9600 on the second line of the display. 5) Verify that your computer’s IR station (Base Station, JetEye, or internal IR transceiver) is attached to the computer and ready to use. 6) Position the DuraTrax/LaserLite to communicate with the computer, by either inserting the unit into the Base Station or by pointing its IR transmitter (located in the end cap) towards the JetEye or built-in IR transceiver. The next steps guide you through resending the operating system software to the DuraTrax/LaserLite. You must use the appropriate steps for your computer system: • • •

76

If you are using Windows, go to Step 7 on page 76. If you are using DOS, go to Step 7 on page 80. If you are using a Macintosh computer, go to Step 7 on page 82.

Appendix F Resetting the DuraTrax/LaserLite

Page 85

For Windows users (from page 75): If you have previously used Vxcomm.exe to transfer data from the unit, proceed to Step 9. If you have not used Vxcomm.exe to transfer data, complete Steps 7 and 8 before proceeding to Step 9. 7) Choose the Run command from the Windows Start menu and click Browse (Figure F-1).

Figure F-1 Run Window - Click Browse 8) Locate and open Vxcomm.exe. Click at the end of the path name to add the parameters (Figure F-2). The syntax is: [-p<port number>] [-d<configuration>]. Spaces are used to separate the parameters.

Figure F-2 Add Vxcomm.exe Parameters The first parameter is the serial port (-p); the program uses 1 by default. If you are using serial port 1, you do not need to enter this parameter. If you are using serial ports 2, 3, or 4, you must enter a -p followed by the serial port number (that is, -p2 for serial Appendix F Resetting the DuraTrax/LaserLite

77

Page 86

port 2, -p3 for serial port 3, -p4 for serial port 4). The next parameter is configuration (-d); the program uses 0 by default. If you are using a Base Station or a built-in IR transceiver, you do not need to enter this parameter. If you are using a JetEye, you must enter a -d1. Enter the appropriate parameters and click OK to close the Run window and save the entry. See Table F-1 on page 79 for a list of the transfer parameters. (Note: The transfer parameters need to be entered the first time you use Vxcomm.exe; you do not need to enter the parameters again unless the serial port or configuration settings are changed.) 9) Resend the operating system software to the unit by dragging the operating system file icon together with the Default.S icon to the Vxcomm.exe icon. For DuraTrax the operating system software is Trax125a.OS, and for LaserLite the operating system software is Lite125a.OS. (Note: The actual filename of your operating system files may be different, because the last characters of the name (125a) will change as new versions of the software are released. However, the filename will always begin with a T for a DuraTrax, an L for a LaserLite, and have a .OS extension.)

78

Appendix F Resetting the DuraTrax/LaserLite

Page 87

10) Vxcomm.exe begins looking for the DuraTrax/LaserLite. Press any button on the DuraTrax/LaserLite to begin the transfer. A window opens (Figure F-3) and reports the progress of the transfer.

Figure F-3 Progress Window (See Chapter 1 of the Developer’s Reference manual for complete information on Vxcomm.exe.)

Appendix F Resetting the DuraTrax/LaserLite

79

Page 88

The following table summarizes the parameters for Vxcomm.exe and DOWNLOAD.exe: Serial Port

IR Device

Parameters to Enter

Actual Parameters the Software Uses

1

Base Station or Built-in IR

-p1 -d0 (default)

2

Base Station or Built-in IR

-p2

-p2 -d0

3

Base Station or Built-in IR

-p3

-p3 -d0

4

Base Station or Built-in IR

-p4

-p4 -d0

1

JetEye

-d1

-p1 -d1

2

JetEye

-p2 -d1

-p2 -d1

3

JetEye

-p3 -d1

-p3 -d1

4

JetEye

-p4 -d1

-p4 -d1

Table F-1 Transfer Parameters

80

Appendix F Resetting the DuraTrax/LaserLite

Page 89

For DOS users (from page 75): 7) To resend the operating system software to the unit with DOWNLOAD.exe, use the following syntax: DOWNLOAD sys.os -pn -dn where sys.os is the name of the operating system file (Trax125a.OS for DuraTrax and Lite125a.OS for LaserLite); -pn specifies the serial port (default is 1); and -dn specifies the configuration (0 (default) for a Base Station or built-in IR transceiver, 1 for JetEye). (Note: The actual filename of your operating system file may be different, because the last characters of the name (125a) will change as new versions of the software are released. However, the filename will always begin with a T for a DuraTrax, an L for a LaserLite, and have a .OS extension.) See Table F-1 on page 79 for a list of the transfer parameters. For example, to send the operating system file to a LaserLite using serial port 2 and a JetEye, you would type the following at the DOS prompt: DOWNLOAD Lite125a.OS -p2 -d1 To send the operating system file to a DuraTrax using serial port 1 and a Base Station, you would type the following at the DOS prompt: DOWNLOAD Trax125a.OS

Appendix F Resetting the DuraTrax/LaserLite

81

Page 90

To send the operating system file to a DuraTrax using serial port 3 and a Base Station, you would type the following at the DOS prompt: DOWNLOAD Trax125a.OS -p3 (See the Developer’s Reference manual for complete information on DOWNLOAD.exe.)

82

Appendix F Resetting the DuraTrax/LaserLite