Page 61
Appendix E Using Multiple Data Collectors and Base Stations Contents P. 54 P. 56 P. 62 P. 64 P. 74
Connecting the Base Station Changing a Data Collector’s ID with a Windows or DOS Computer Changing a Data Collector’s ID with a Macintosh Computer Transferring Data from Multiple Data Collectors Notes on Using Multiple Data Collectors
Appendix E Using Multiple Data Collectors and Base Stations
53
Page 62
Connecting the Base Stations Videx Base Stations can be connected in series; this allows the user to transfer data from up to ten base stations (or 20 data collectors) in a single transfer process. To connect multiple Base Stations: 1) Connect the first Base Station to the computer’s serial port: a) Plug the Base Station’s transformer into an electric outlet and connect the other end into the Base Station’s Power connection. b) Use the serial port cable to connect the computer’s serial port to the Base Station’s Computer port. c) The Base Station should be placed at least 3 inches away from the computer and monitor. 2) To add additional Base Stations: a) Use an interconnect cable (TWC-006) to connect the Extension port of the first Base Station to the Computer port on the second Base Station. See Figure E-1. b) Continue the same pattern of connection for each additional unit.
54
Appendix E Using Multiple Data Collectors and Base Stations
Page 63
Figure E-1 Base Stations in Series You can connect up to ten Base Stations to a single serial port.
Appendix E Using Multiple Data Collectors and Base Stations
55
Page 64
Changing an ID with a Windows Computer When using multiple Base Stations, you must give each data collector a unique ID; this allows the computer to access each data collector and verify that it has transferred the data from each one. To assign an ID, you must first create a commands text file, then click and drag the file onto the Vxcomm.exe icon. Vxcomm.exe then uses the commands file to unlock the unit and change the ID. (For complete information on Vxcomm.exe and using a commands text file, see Chapter 1 of the Developer’s Reference manual.) During normal operation, a unit is given an ID of ten zeros. To change the ID, you must create a text file consisting of the following three command lines: 1) an I command, followed by a space, followed by ten zeros to unlock the unit; 2) a C command, followed by a space, followed by the new ID for the unit; 3) and an L command to relock the unit. I 0000000000
Sends an unlock command to the data collector. (Note: Ten zeros will unlock any data collector.)
C new ID#
Changes the unit’s ID to the given ID. The ID can be any alphanumeric combination of up to ten characters in length. For example, if you want an ID of 1, this line should be C 1; if you want an ID of BuildingD, this line should be C BuildingD; if you want an ID of 123#_AB, this line should be C 123#_AB, and so on.
L
Sends a LOCK command and puts the data collector to sleep. When the unit is awakened with a keypress, it immediately runs the current application.
56
Appendix E Using Multiple Data Collectors and Base Stations
Page 65
For example, to change a unit’s ID to 12345: 1.
Use your word processing program to create a text file containing the following three lines: I 0000000000 C 12345 L
2.
Save the file as a text file and quit the program. (Note: The text file must have a .txt extension.)
3.
Place a data collector into the Base Station slot.
IMPORTANT: When you are sending a file to a data collector, it must be the ONLY data collector attached to the computer. 4.
Click and drag the text file you created onto the Vxcomm.exe icon.
5.
Vxcomm.exe executes the commands listed in the text file: it unlocks the unit, changes the ID to what is listed after the C command (in this case, 12345), and then relocks the unit.
6.
Remove your data collector from the Base Station slot; your data collector is ready to use.
Appendix E Using Multiple Data Collectors and Base Stations
57
Page 66
To continue changing other data collector’s IDs: 1.
Reopen the text file.
2.
Change the ID listed after the C command by selecting 12345 and typing in a new ID. (Note: There must be a space character between the C and the ID.)
3.
Save and close the text file. Remember, the text file must have a .txt extension.
4.
Insert a data collector into the Base Station slot.
5.
Click and drag the edited text file to the Vxcomm.exe icon.
6.
Vxcomm.exe executes the commands listed in the text file: it unlocks the unit, changes its ID to what is listed after the C command, and then relocks the unit.
7.
Continue these same steps until you have assigned a unique ID to each of your units.
Note: Keep a list of the IDs you are using to identify your data collectors. You will use this list in the section “Transferring Data from Multiple Units.”
58
Appendix E Using Multiple Data Collectors and Base Stations
Page 67
Changing a Data Collector’s ID with a DOS Computer To assign a unique ID when using a DOS computer, you must first create a commands text file, then enter the name of the commands text file on the Download.exe command line. Download.exe then uses the commands file to unlock the unit and change the ID. (For complete information on Download.exe and using a commands text file, see Chapter 1 of the Developer’s Reference manual During normal operation, a unit is given an ID of ten zeros. To change the ID, you must create a text file consisting of the following three command lines: 1) an I command, followed by a space, followed by ten zeros to unlock the unit; 2) a C command, followed by a space, followed by the new ID for the unit; 3) and an L command to relock the unit.
Appendix E Using Multiple Data Collectors and Base Stations
59
Page 68
I 0000000000
Sends an unlock command to the data collector. (Note: Ten zeros will unlock any data collector.)
C new ID#
Changes the unit’s ID to the given ID. The ID can be any alphanumeric combination of up to ten characters in length. For example, if you want an ID of 1, this line should be C 1; if you want an ID of BuildingD, this line should be C BuildingD; if you want an ID of 123#_AB, this line should be C 123#_AB, and so on.
L
Sends a LOCK command and puts the data collector to sleep. When the unit is awakened with a keypress, it immediately runs the current application.
For example, to change a unit’s ID to 12345: 1.
Use your word processing program to create a text file containing the following three lines: I 0000000000 C 12345 L
2.
Save the file as a text file and quit the program. (Note: The text file must have a .txt extension.)
3.
Place a data collector into the Base Station slot.
IMPORTANT: When you are sending a file to a data collector, it must be the ONLY data collector attached to the computer. 4. Enter the name of the commands text file on the Download.exe command line use the following syntax: DOWNLOAD commands.txt -pn -dn where commands.txt is the name of the commands text file,
60
Appendix E Using Multiple Data Collectors and Base Stations
Page 69
-pn specifies the serial port (default is 1), and -dn specifies the configuration (0 for Base Station or built-in IR transceiver (default), 1 for JetEye). 5.
Download.exe executes the commands listed in the text file: it unlocks the unit, changes the ID to what is listed after the C command (in this case, 12345), and then relocks the unit.
6.
Remove your data collector from the Base Station slot; your data collector is ready to use.
To continue changing other data collector’s IDs: 1.
Reopen the text file.
2.
Change the ID listed after the C command, by selecting 12345 and typing in a new ID. (Note: There must be a space character between the C and the ID.)
3.
Save and close the text file. Remember, the text file must have a .txt extension.
4.
Insert a data collector into the Base Station slot.
5.
Resend the Download command line containing the name of the commands text file.
6.
Download.exe executes the commands listed in the text file: it unlocks the unit, changes its ID to what is listed after the C command, and then relocks the unit.
7.
Continue these same steps until you have assigned a unique ID to each of your units.
Note: Keep a list of the IDs you are using to identify your data collectors. You will use this list in the section “Transferring Data from Multiple Units.”
Appendix E Using Multiple Data Collectors and Base Stations
61
Page 70
Changing an ID with a Macintosh Computer To assign a unique ID when using a Macintosh computer, you must first create a commands text file, then click and drag the file onto the Videx Download icon. Videx Download then uses the commands file to unlock the unit and change the ID. (For complete information on Videx Download and using a commands text file, see Chapter 1 of the Developer’s Reference manual.) During normal operation, a unit is given an ID of ten zeros. To change the ID, you must create a text file consisting of the following three command lines: 1) an I command, followed by a space, followed by ten zeros to unlock the unit; 2) a C command, followed by a space, followed by the new ID for the unit; 3) and an L command to relock the unit. For example, to change a unit’s ID to 12345: 1.
Use your word processing program to create a text file containing the following three lines: I 0000000000 C 12345 L
2.
Save the file as a text file and quit the program. (Note: The text file must have a .txt extension.)
3.
Place a data collector into the Base Station slot.
IMPORTANT: When you are sending a file to a data collector, it must be the ONLY data collector attached to the computer. 4.
Click and drag the text file you created onto the Videx Download icon.
62