Page 31

25

Coaxial Cable Recommendations Caution: Careful selection of proper cable is essential to obtain the best performance from this equipment. Vicon assumes no responsibility for poor performance when cables other than those recommended, or equivalent, are installed. In all cases, coaxial cable impedance should be 75 ohms.

Materials Use only a pure copper center conductor. Do not use a copper-plated steel or aluminum center conductor, as they will result in poor quality video. Solid-core bare copper conductor is the best type, where flexing and bending will be minimal. If severe bending and flexing is required for installation, use a stranded center conductor. Never exceed the manufacturer’s minimum bend radius specification. Use cellular (foam) polyethylene dielectric except where heavy moisture exists. For moisture conditions, use solid polyethylene dielectric cable with a heavy exterior insulation. The shield must be copper braid providing 95% or better coverage.

Cable Types The cable types listed below are the most common 75-ohm types used. They vary in size (diameter), dielectric type and net DC resistance. The larger cable results in a lower DC resistance and better video quality, with increased difficulty in handling and installation. Let the required picture quality and cable distance provide a guide in choosing the best cable type. For cables other than the approved Vicon types below, contact the manufacturers listed below. Note that “BC” refers to bare copper and “TC” refers to tinned copper.

Recommended Coaxial Cable Types Cable Type

RG-11/U RG-6/U RG-59/U RG-59/U RG-59/U

Belden Type No.

Alpha Type No.

West Penn Type No.

Type Center Conductor

Type Shield and % Coverage

DC Resistance ohms/1000 ft (km)

8213 9248 8281* 9259 9659

9847 9804C ---9803 ----

811,4811 806,4806 815 816 ----

14 Solid BC 18 Solid BC 20 Solid BC 22 Stranded BC 22 Stranded BC

BC braid (95%) Foil + 61% TC braid (100%) 2 TC braids (96%) BC braid (95%) BC braid (95%)

2.6 (8.5) 7.5 (24.6) 9.9 (32.5) 15.0 (49) 15.0 (49)

*Requires special BNC-M connector due to 0.305 nominal O.D. Belden Inc.

http://www.belden.com/

Alpha Wire Company

(800) 235-3361 http://www.alphawire.com/

West Penn Wire

(800)-52 ALPHA (522-5742)

http://www.westpenn-cdt.com/

(800)-245-4964

Picture Quality vs. Cable Length Picture Quality Usable picture Clean picture Best picture

Maximum Cable Run** ft (m) RG-59/U RG-6/U RG-11/U 1100 (350) 1500 (450) 2400 (750) 820 (250) 1000 (300) 1600 (500) 400 (120) 530 (160) 820 (250)

** For longer cable runs, use a Vicon Video Amplifier to obtain a suitable picture.

XX181-02-00 Rev 1107 VN-855 Ver 3 IP Camera

Page 32

26

Twisted-Pair Cable Caution: Careful selection of proper cable is essential to obtain the best performance. Vicon assumes no responsibility for poor performance when cables other than the recommended types, or equivalent, are used.

Materials Use a pure copper stranded conductor with or without a tin-plating to obtain a low DC resistance. Do not use cable with either steel or aluminum stranded conductor because they do not transfer signals effectively for long distances. The preferred insulation and cable jacket is Polyvinyl chloride (PVC). It has better electrical characteristics than polyethylene and resists flames, sunlight and most solvents, but is more vulnerable to moisture.

Cable Types The most commonly used cable types are dual individually-shielded, twisted pair in a single jacket. This configuration is the most convenient for RS-422/ RS485 applications. Single individually-shielded, twisted pair is also a suitable cable.

Choose a Belden cable type by referring to the characteristics and maximum distances listed below. The maximum distance for the most reliable digital control refers to the distance between the CPU/Keypad and the Camera Assembly. The characteristics of the cables in Table 6 should be used as a guideline when cables other than Belden are used. Materials and construction must follow the guidelines above.

CABLE TYPE Belden 9406 Belden 9402 Belden 8723 Belden 8162 Belden 9729 Belden 9182

WIRE SIZE (AWG) 22 20 22 24 24 22

INSULATION MATERIAL PVC PVC Polypropylene Datalene¹ Datalene¹ Datalene¹

JACKET MATERIAL PVC PVC PVC PVC PVC PVC

DISTANCE ft (m) max. 5000 (1500) 5000 (1500) 8000 (2400) 15000 (4600) 15000 (4600) 25000 (7600)

NUMBER OF TWISTED PAIRS

¹Datalene is a Registered Trademark of Belden. Belden Inc. http://www.belden.com/(800) 235-3361

Table Recommended Individually-Shielded, Twisted-Pair Cable Types

XX181-02-00 Rev 1107 VN-855 Ver 3 IP Camera

2 2 2 2 2 1

Page 33

27

Network Cable Caution: Careful selection of proper cable is essential to obtain the best performance. Vicon assumes no responsibility for poor performance when cables other than the recommended types, or equivalent, are used.

Materials Use pure copper stranded conductors to obtain a low DC resistance. The preferred insulation and cable jacket is Polyvinyl chloride (PVC). It has better electrical characteristics than Polyethylene and resists flames, sunlight and most solvents, but is more vulnerable to moisture.

Cable Types The most commonly used cable types are CAT5, CAT5e and CAT6. These category cables are best suited for Ethernet network applications.

Choose a Belden cable type by referring to the characteristics listed below. The Table below should be used as a guideline when cables other than Belden are used. Materials and construction must follow the guidelines above.

CABLE TYPE

WIRE SIZE (AWG)

Belden 1624P Belden 1583A

24 24

Belden 1585A Belden 7883A

24 24

INSULATION MATERIAL Flourinated Ethylene Propylene Polyolefin Flourinated Ethylene Propylene Polyolefin

JACKET MATERIAL

CATEGORY

BANDWIDTH (MHz)

MAXIMUM DISTANCE (ft/m)

NUMBER OF TWISTED PAIRS

Low Smoke PVC PVC

5 5e

100 100

328/100* 328/100

4 4

PVC PVC

5e 6

100 250

328/100 328/100

4 4

*For any cable in the system exceeding 300 ft (75 m), it is recommended to use Cat5e or higher to maintain good signal integrity. Belden Inc. http://www.belden.com/ (800) 235-3361

Table Recommended Network Cable Types

XX181-02-00 Rev 1107 VN-855 Ver 3 IP Camera

Page 34

28

Technical Information ELECTRICAL Input Power Source: Input Power Isolation: Current:

Power Consumption:

Heat Equivalent:

Maximum Power Cable Distance: Radio-Frequency Emission Standard:

24 VAC, ±15% or PoE (802.3af compatible).

SOFTWARE OPERATION

Internal fully isolated power input.

Network Setup:

Standard network protocol type using IP addressing scheme and separate PC application software.

Site Authorization:

Camera can be setup using remote recorder or workstation GUI. Permissions can be assigned for macro create & edit, alarm setup, Authentication, Reports and System Status. Supports up to 20 Groups and 100 Users.

Macro Create & Edit:

System macros can be configured to use the camera’s video. In addition, within macros, alarms can be sent and remote macros run.

Alarm Setup:

An alarm can be triggered on video motion detection and loss. The alarm can be sent to remote units.

Authentication:

The video from the camera can be set to view the Authentication status symbol (A) on the displayed video.

VN-855: 360 mA max. VN-855DN: 410 mA max. VN-855WDR: 380 mA max. 250 mA @48 VDC (PoE) VN-855: 5.8 W max. VN-855DN: 6.5 W max. VN-855WDR: 6.4 W max. 0.3 btu/min (0.09 kg-cal/min) nominal. Note: These figures represent the conversion of 100% of the electrical energy to heat. Actual percentage of heat generated will be less and will vary from product to product. These figures are provided as an aid in determining the extent of cooling required for an installation. Refer to Table 1 (based on 24 VAC, standard camera).

Picture Quality and FPS Priority:

FCC Class A/CE.

VICONNET (IP) Communication System: LAN Interface: Number of Video Channels: Video Formats Supported: Video Transmission Rate: Number of Simultaneous Video Streams: Video Quality:

Audio:

Alarm: Video Bandwidth: Hard Drive Consumption Rate:

VN-855V4

Days Recording

ViconNet Digital Video Management System Version 4.

Camera video can be setup to prioritize recorded picture quality and video FPS. Priority can be assigned to user/macro recording for highest requested video quality or Master user control.

VIDEO CHARACTERISTICS Image Device:

10/100 Mbps, TCP/IP Unicast.

Active Picture Elements:

1, over LAN connection.

Sensitivity:

NTSC and PAL, model dependant. 30 fps (25 fps, PAL).

Maximum 10 viewing/recording streams per camera. ViconNet software quality 1-8, selectable on a 4-position bar with 2 compression level settings in resolutions 720 x 488 (863 x 586 PAL), 720 x 244 (863 x 293, PAL), 360 x 244 (432 x 293, PAL), 360 x 122 (432 x 146, PAL). 1 line-level microphone input; 0 dbm, 32 KHz bandwidth, 600 ohm impedance, 2 V RMS (1 V p-p) output.

Horizontal Resolution: Electronic Iris: Scanning System:

Backlight Compensation/Wide Dynamic Range:

1/3-inch interline transfer CCD. NTSC: 768 (H) x 494 (V). PAL: 752 (H) x 582 (V). VN-855/VN-855WDR 0.09 fc (1.0 lux) at standard gain; 0.07 fc (0.7 lux) at high gain. VN-855DN 0.0009 fc (0.01 lux) in night mode; 0.07 fc (0.7 lux) in day mode. Conditions: lens at f/1.2 and 40 IRE video output. VN-855/ N-855DN: 540 lines VN-855WDR: 480 lines. NTSC: 1/60-1/100,000. PAL: 1/50-1/100,000. NTSC standard: 2:1 interlace, 525 lines, 30 frames/sec. PAL standard: 2:1 interlace, 625 lines, 25 frames/sec. ON/OFF select.

1, select N.O./N.C. 1.7 Mbps (per video stream), nom. Refer to Table 2.

Table 2 Hard Drive Consumption

60

200

300

Remote Hard Drive Storage (GB) 500 600 900

1000

2000

3000

24

80

120

200

400

800

1200

240

360

Note: This table is based on the following conditions: - 24 hours normal activity with 50% detected movement over time, Normal compression and Quality Q5 (320 x 240 pixels NTSC, 384 x 288 pixels PAL) - Recording durations may vary based on actual scene activity.

XX181-02-00 Rev 1107 VN-855 Ver 3 IP Camera