Page 11
EXTERNAL SYNC CONNECTION
(VC2200-24G and -GC models only) Supply a composite video signal or composite sync signal, which is used as an external sync reference signal, to the EXT SYNC con- nector to perform genlock operation with other equipment. See Figure 1.
NOTE: To insure genlock operation, be sure the external sync signal level is be- tween 0.2 and 2.0 Vp-p. (Use RG- 59B/U.)
The genlock operates when composite signal is applied from any external sync source.
The sync signal at the SYNC OUT connector is generated by the VC2200 and can be used to drive other cameras or video equipment with genlock capability. The output signal at the SYNC OUT connector is a composite sync signal (2.0 Vp-p, 75 ohms terminated). See Figure 1.
NOTE: (VC2200-24 VAC models only) Select internal/external sync by setting the SYNC MODE switch to the INT/EXT position. See Figure 12.
POWER CONNECTIONS
@ VC2200-24 VAC Models
NOTE: Do not apply power until connections are completed.
The VC2200 is powered by 24 VAC (+10 %). Refer to Figures 1 and 8. (24 VAC line is completely isolated by transformer.)
For 24 VAC installations, connect the power cable to the terminals marked 24 VAC. See Figure 8. (Usable only with the source which meets Class 2 Specifications.)
The camera will be operational, as indicated by the POWER LED on the rear panel.
whenever power is applied.
e VC2200-12 VDC Models
NOTE: Do not apply power until connections are completed.
The VC2200 is powered by 11~16 VDC. Re- fer to Figures 1 and 8.
The camera will be operational, as indicated by the POWER LED on the rear panel, whenever power is applied.
FROM 12 VDC POWER SOURCE
12 VDC Models
FROM 24 VAC POWER SOURCE
24 VAC Models
Figure 8 Power Terminal Blocks
11
Page 12
MECHANICAL FOCUS ADJUSTMENT
The VC2200 has been factory adjusted for proper mechanical focus. However, when the lens is mounted, it may be necessary to read-just the back focus.
FIXED-FOCAL-LENGTH LENSES
1. Mount lens on camera. Complete power and video connections.
2. Set the focus ring to infinity («}) and open the iris completely.
NOTE: The illumination tevel may have to be reduced to permit opening the iris.
3. Loosen the focus lock screw (Figure 9).
4. Position the camera to view an object greater than 35 feet (10 m) away.
5. Turn back focus cam to obtain the shar- pest possible image.
6. Retighten the focus lock screw.
BACK FOCUS CAM
ZOOM LENSES
. Follows steps 1 through 4 as explained in the procedure for FIXED-FOCAL-LENGTH LENSES.
2. Set the lens to its maximum telephoto position and adjust the lens focusing ring to the sharpest possible image.
. Set the lens to its maximum wide angie position and adjust the back focus cam (Figure 9) on the camera for the sharpest possible image.
. Repeat steps 2 and 3 until sharpness re- mains stable during zooming.
. Retighten the focus lock screw.
Lo fo) ©
L
HH ® PICT wOO TF SNOOI
) © bd Al Vy ~PHASE © jure H - PHASE
FOCUS LOCK SCREW
Figure 9
Mechanical Focus Adjustment Screws
12
Page 13
ADJUSTMENTS
Adjust the camera's settings depending on the shooting conditions. Adjustment controls located on the top plate surface (24 VAC only) or the side plate surface (12 VDC only) of the camera include:
e ALC for lens (see “Lens Installation” section)
@ Horizontal phase (VC2200-24G and -24GC models only)
® Vertical phase (24 VAC models only)
The holes for these adjustment controls are covered with grommets. Controls located below the top plate include:
@ Automatic Gain Control (AGC) (All models) @ Sync mode (24 VAC models)
13
ALC CONTROL
Refer to “VC2200 Autoiris Sensitivity Adjustment” (page 9) for details.
Page 14
HORIZONTAL PHASE (EXT) CONTROL
(VC2200-24G and -24GC only)
Horizontal phase may need to be adjusted when the camera is installed to operate with an external sync signal. (Horizontal phase is adjustable over the range +3 psec.) Make this adjustment when the horizontal phase of the camera does not match with other cam- eras (or systems). See Figure 10. For correct adjustment, use a multichannel oscilloscope. Horizontal phase can only be adjusted when the camera is genlocked to an external sync signal.
NOTE: Genlock operation is not possible us- ing a jittery input signal, such as the playback signa! from a video recor- der.
14
VERTICAL PHASE (LINE LOCK) CONTROL
(24 VAC models only)
if the camera is to be used in the LINE- LOCKED mode, the vertical phase may re- quire adjustment to synchronize the vertical phase of the camera with other cameras in the system. (Vertical phase is adjustable over the range of +90°). Make this adjustment when the vertical phase of the camera does not match with other cameras (or systems). See Figure 10. For correct adjustment. use a multichannel oscilloscope. This vertical phase adjustment can only be made when the camera is operating in the LINE-LOCKED mode.
NOTES: Cameras designed to EIA RS-170 specifications cannot be line-locked to a 50Hz power source, and CCIR cameras cannot be line-locked to a 60Hz source.
When adjusting the vertical phase (LINE LOCK), to observe the 24 VAC waveform, connect the posi- tive pin of the oscilloscope probe to either of the 24 VAC connectors.
Page 15
Side View
Top View
Top View
+¢
VICON
}
=z
@ :
ALC CONTROL ikaalll
|
VC2200-12 VC2200-12C
ALC CONTROL
OO Sn04?
oO
V, PHASE @) ® li © VC2200-24
VC2200-24C V PHASE CONTROL
ALC CONTROL
L
°, w @l | iS o- [e) V, PHASE ©) © al H - PHASE @) N VC2200-24G
V PHASE CONTROL H PHASE CONTROL
VC2200-24GC
Figure 10 Adjustment Controls
15
Page 16
AUTOMATIC GAIN CONTROL (AGC)
The AGC circuit incorporated into the camera boosts the sensitivity automatically when the scene illumination is insufficient.
An on-off switch is provided for the AGC circuit. This switch is set to the ON position at the factory. If it is necessary to turn the AGC off, set the AGC switch to the OFF position using the “How to Open the Case” procedure (Figure 11). See Figure 12 for the location of the switch.
SYNCHRONIZATION
All VC2200 camera models are equipped with internal synchronization. In addition, all 24 VAC models have switch selectable LINE LOCKING synchronization. This synchronizes the camera to the 60Hz AC line power signal (50Hz for CCIR cameras). The VC2200-24G and -24GC feature an external BNC connec- tor to permit synchronization by external equipment.
12 VDC Models
These rely solely on an internal clock for synchronization. There is no sync switch to set on these cameras.
VC2200-24 and -24C Models - Line Lock- ing or Internal Sync.
The VC2200-24 and -24C can operate either on internal sync or use power line phase- locked sync (line-locked sync). Access the internal switches using the “How to Open the Case” procedure (Figure 11). Set the sync switch (Figure 12) to the appropriate position (LINE LOCK or INTERNAL).
16
VC2200-24G and -24GC Models - Line Locking or Internal Sync.
The VC2200-24G and -24GC can operate either on internal sync, external sync or use power line phase-locked sync (line-locked sync).
When the camera detects a signa! at the ex- ternal sync BNC connector, it automatically synchronizes to that signal.
Internal Sync: the sync switch must be set to the INTERNAL position.
Line-Locking Sync: the sync switch must be set to LINE LOCK position. It then synchro- nizes to the power line signal.
Sync Switch Setting: to set the switch, access the internal switches using the “How to Open the Case” procedure (Figure 11). Set the sync switch (Figure 12) in the appropriate position (LINE LOCK or INTERNAL)
Page 17
HOW TO OPEN THE CASE
1. Remove the four (4) screws (a) shown in
Figure 11.
Loosen the three (3) screws (b) shown in
Figure 11 to remove the mounting base.
3. Remove the four (4) screws (c) shown in Figure 11 to detach the right and left cases.
(@)
a,
°
L x, =
H
WOO) SNDOSs oO
O}”..
x kf ae x
Eta}
Top View sen wo Cd) wes cove)
y, i
OC Z ®
O wa
=
Bottom View sen no
&) ® e)
KH
© S
Bottom View without the Mounting Base
Figure 11 How to Open the Case
17
Page 18
SYNC MODE SWITCH, =ff re ] . Jl 5 “LINE LOCK” NI | AGC SWITCH iS: it ke . o “INTERNAL”, ~ . Lo i i > h Ll __J | Top View without Cases iv “t | AGC SWITCH mae io LL 1) “OFF” i ] VC2200-12 i f Ny VC2200-12C “ON” | Side View without Cases L | VC2200-24 vC2200-24C Side View without Cases SYNC MODE SWITCH on om iz We LS | Top View without Cases “eg sures “OFF” , ib f “ON” ! 1 L Lj | Need Fig 12 VC2200-24G VC2200-24GC AGC Switch and SYNC Mode Switch Side View without Cases
18
Page 19
MAINTENANCE
The VC2200 does not require scheduled maintenance.
SERVICE
You must have a Return Authorization (RA) number to return a unit to Vicon.
if a unit must be returned to the factory:
1. Obtain RA number from one of the fol- lowing locations:
VICON INDUSTRIES INC. VICON INDUSTRIES INC
525 Broad Hollow Road Southeastern
Melville, New York 11747 Regionai Office
516-293-2200 3010 Business Park
800-645-9116 Dr.. Ste. B Norcross. Georgia 30071 404-449-0499 800-824-8479
. Fully describe the problem and the circum
VICON INDUSTRIES INC. Western Regional Office 950 West Central Ave.. Unit C Brea,
California 92621 714-990-3858
800-648- 1832/33
VICON INDUSTRIES (U.K.) LTD. Gunstore Road Hiisea, Portsmouth Hampshire PO35JP. England
(0705) 665312
SHIPPING INSTRUCTIONS
_ Include the RA number, the name of the person who issued the number, and your company’s name and address with your returned unit. The Vicon RA number MUST appear on any corresponc- ence concerning the unit being shipped.
. Include a brief description of the instai- lation.
stances under which it occurs.
. Indicate the unit's original date of pur- chase.
. Attach all the above information to the unit.
. Pack the unit carefully, using the origi- nal shipping carton or its equivalent, for maximum protection.
_ Mark the RA number on the outside of the carton, preferably on the shipping label.
19
Page 20
Printed in Japan Copyright (© 1989 Vicon Industries Inc. All Rights Reserved (A) 1