Page 321 read from a scan by OCR; it may hold reading errors

Appendix H. EPROM Naming Conventions

Element Type Description

| range (continued)

Italy (prompts)

U.K. (Special PTT requirements)

Spanish (with DES encryption)

Sweden (prompts and PTT requirements)

USPS custom EPROM (protocol and communication)

CULLUM custom EPROM enhancements Mexico (PTT and 15-digit support for amount.)

x s<cH

N <

If "Y" of element "I" is in position 5:

South Africa (English prompts) Thailand

Denmark2 w/alternate Danish prompts Denmark w/Danish prompts

Sharp ECR interface

French prompts w/French Telco Sys. German prompts and telephone protocol Belgian with French prompts

Generic International

Belgian with Dutch prompts

UK, Barclays with English prompts Finnish EPROM w/Swedish prompts Morocco with French prompts

NCR Canada DATPAC 3201 English Barcode *Y to *U error passing Portugal with Portuguese prompts Spanish prompts with Spain Telco Sys. Turkey with Turkish prompts

Austria with German prompts Venezuela with Spanish prompts

<CcCAQOWVZSTHRe -TWOmMmMovooOoWV>

If "V" of element "I" is in position 5:

Discover voice (USA telco system) RS232 leased line terminal

ValuCard EPROMs (USA telco system) TRANZ 330 fast connect nm“™< 39m

Page 322 read from a scan by OCR; it may hold reading errors

TCL Programmer’s Manual

Element

Type

Description r Range:

> z

DTOWDrFeMMNOAWNA =

Magnetic Cardreader Type

Track 1 (code 39 bar code)

Track 2 (code 39 bar code)

Track 2 (UPC-A bar code)

Track 1 (UPC-A bar code)

N/A (no mag cardreader capability) Track 1 (1 2 of 5 Bar Code Telec.) Track 2 (I 2 of 5 Bar Code Telec.) Track 2 (| 2 of 5 Bar Code - Standard) Dual track and code 39 Bar Code Dual track and UPC-A Bar Code Dual track and | 2 of 5 Bar Code Dual track and no Bar Code

Range:

VOUPrs

AIQumM zr

Modem Type

300 Baud, Bell 103

300 Baud, CCITT V.21

1200 Baud, Bell 212A (Fairchild)

Bell 103/212a & CCITT V.21/V.22

(SST K-222 modem)

Bell 103/212a Only (SST K-222 modem) RS485 LAN, 19.2K Baud

CCITT V.21/V.22 only (SSI K-322 modem) Bell 202 (4-wire leased-line)

Bell 103/212a & CCITT V.21/V.22 (Rockwell 2424)

Bell 103/212a only (Rockwell 2424) CCITT V.23 modem

Range:

ZErxceoTrTO mMoowrs

Telephone System Compatibility/Timing Australia

Burroughs Poll Select Leased-line protocol Czechoslovakia

Datapac 3201 leased line protocol Greece

Finland

Great Britain (UK)

Hong Kong

Austria

Reserved for future use

Denmark

Standard Leased line protocol

Tinet Cluster Leased-line

VeriFone LAN (1340, T240)

Page 323 read from a scan by OCR; it may hold reading errors

Examples

Appendix H. EPROM Naming Conventions

Element Type Description t range (continued)

Norway

Philippines

Reserved for future use

PSTN Indonesia

Singapore

Portugal

USA

Refer to position 2 for country customer code Switzerland

Reserved for future use

Refer to position 2 for country customer code New Zealand

N<xXS<CAHHDOVOS a 1AN Release Audience Identifier Range: A-Z Alpha character (increments for each internal release made); @-9 Numeric character indicating current production release

An XL v.21 Track 2 EPROM with Columbian prompts is named "XC2BU22B". The parameters indicate it is the second alpha/beta release of the twenty-second software release for this product.

A TRANZ 330 Bell 103 EPROM for Latin America is named "3S1AU030". The parameters indicate it is the first production version of the third software release for this product.

A TRANZiT 1200C multi-teico EPROM is name "TE9DU100". The parameters indicate it is the first production version of the first software release for this product.

H-§

Page 324 read from a scan by OCR; it may hold reading errors

TCL Programmer’s Manual

Page 325 read from a scan by OCR; it may hold reading errors

Overview

Procedure

Appendix I. Writing Soft Logins

The purpose of a generic login is to have one routine at the operating system level that will be a login string interpreter capable of handling all logins. Logins function the same to:

¢ Transmit information

¢ Receive information

¢ Wait for specified periods of time ¢ Display messages

TRANZ 330 EPROM version 3.30 and greater, and all TRANZ 380 releases, feature a generic login that can be programmed at the application level. Previously, all logins were hard-coded in the EPROM requiring that new firmware be created to add each new protocol. This feature accommodates ACCUNET and GEISCO logins, requires fewer field EPROM upgrades, and allows faster protocol support development.

Note: In international and industrial versions of XL EPROMs greater than 2.70, TRANZ 330 EPROMs greater than 3.40, and TRANZ 380, the only hard coded login supported is Tymnet. All other industrial and international EPROMs must have logins coded with the soft (generic) login method. Domestic versions do support hard-coded logins with the exception of TRANZ 330, version 3.60

Follow the current method for specifying logins by adding a login specifier to the end of a phone number. The specifier instructs the operating system to check a memory location for data on logging into a network protocol specifier, user name, user password, or other IDs.

Note: TRANZ 380 memory locations that correspond to those listed in this section have 4 digits (020=0020, 029=0029, etc.).

You may continue to use "Ln" following the phone number to select a login, where "n" represents a number from 0 to 9 (referencing memory locations 020 - 029). When the terminal dials a phone number and encounters "Ln", the operating system will continue to execute the data at that location. This procedure selects a login that is contained in the EPROM and provides the username, password, and other parameters.

If you wish to select a new login, use "Xn" following the phone number, where "n" represents a number from 0 to 9 (referencing memory locations 020 - 029). When the terminal dials the phone number and encounters "Xn",

Page 326 read from a scan by OCR; it may hold reading errors

Format

Login Control String Commands

TCL Programmer’s Manual the operating system will execute the login control string referenced in memory location "n".

Note: This memory location should be dedicated to performing only a login, then return back to allow normal transaction flows to occur after the login is completed. This was not designed to execute this memory location and do the entire transaction.

The format in memory locations 020 - 029 will remain the same, except that the first parameter will represent the login control string to execute rather than a login selection. The remaining parameters (user name, user password, user location, and location password) separated by a hyphen, will not change.

For example: "350-ABCDEF-1234-XYZ-A1"

In this example, the operating system will execute the login control string at memory location 350 and include a user name of "ABCDEF", a user password of "1234", a user location of "XYZ", and a location password of "A1 "

Access of these four parameters depends upon proper use of the "+X" command. The login contro! string may use any TCL commands supported in the EPROM.

The login sequence is as follows: e The carrier is raised

* The operating system executes the login control string * The terminal waits 30 seconds for an <ENQ>

The TRANZ 330/380 terminal will continue to display all current system messages and error messages.

Three new commands, +P, +X and +Y, are used to help set the login protocol parameters. Refer to section 5, TCL Commands, for details. These new commands are used the same as TCL commands, allowing looping for error recovery.

Exercise caution when using various TCL commands. For example, prompt display commands "F" and "P" will not operate correctly when executed in a login string because of the way they function. To display a message properly during a login, select a buffer, clear the buffer, append the data to be displayed, and use the "V" command to display the contents of the buffer.

You may use other commands in the login provided they are designed for controlling communication and logins. The three new login commands are not limited to login strings. They may be used in any other control string.

Page 327 read from a scan by OCR; it may hold reading errors

Appendix J.

Industrial EPROM

Bar Code Differences

The ZON 530, the ZON 531, the ZON 540, and the ZON 541 are the four VeriFone terminals that comprise the ZON 5XX series. EPROMs that are specifically made for the ZON 5XX series are known as "industrial" EPROMs, but their primary feature is enhanced capability for bar code reading. The ZON 531 and the ZON 541 are capable of reading bar codes in the card slot with the bar code facing left (magnetic stripes face right). Except for the EPROMs, the ZON 530 is like the TRANZ 330, and the ZON 540 is like the TRANZ 340. The ZON 531 is a bar code slot version of the ZON 530; the ZON 541 is a bar code slot version of the ZON 540. These terminals are available in either plastic or metal cases. A bar code wand ora bar code gun scanner may be attached to the DIN 6 port. Contact VeriFone OEM Sales in Atlanta for further information. Bar code symbologies that are available are code 39, interleaved 2 of 5, and UPC-A (and the latter's super-set known as EAN-13). For other bar code symbologies that are not yet available via an EPROM, the user may purchase certain gun scanners that decode the bar code data within that peripheral device.

Differences Between Standard and Loose Industrial EPROMs for Interleaved 2 of 5

Loose 12 of 5 EPROM

Standard I2 of 5 EPROM

Slightly hardened against sub- stitution errors

Very hardened against substitution errors

Can read poorer quality bar codes

Generally requires high quality bar code printing

Minimum number of digits al- lowed is 4

Minimum number of digits allowed is 2

Page 328 read from a scan by OCR; it may hold reading errors

TCL Deletions for Industrial EPROMs

Fourth Optional "*U" Parameter

Using the *Y Command Before the *U Command

Code 39 Error Codes Available Using "*U" 4th Parameter

TCL Programmer’s Manual

Only the following eight fixed prompts are available to the TCL programmer (no hard coded logins such as TYMNET can be used):

Fixed Prompt

No. Prompt

1 ENTER ACCOUNT # 2 EXPIRY DATE MMYY 3 AMOUNT OF SALE? 47 ENTER PASSWORD 59 INVALID PASSWORD 73 PRINTING ...

125 INSERT FORM ...

126 .. PRESS ENTER

The TCL program operating on non-industrial EPROMs has no way of know-ing whether bar code data was read on the first attempt at scanning, or after many attempts, because only a good read is given to the TCL logic. On industrial EPROMs, the "*U" logic is informed that the present bar code scan is either a good read or a no-read. If there is a no-read, two bytes consisting of “I" and an upper case letter error code are put in the interrupt output buffer.

Industrial EPROMs have a fourth (optional) parameter in the "*U" command. This parameter represents the number of TCL commands to skip on a no-read (unsuccessful bar code scan). The TCL programmer may include logic to display or print the error code and/or determine a bar code first read rate via this parameter. Another potential use of this capability is for monitoring the number of scan attempts to read each label, in order to help determine whether a label should be replaced or whether a user needs to be trained on better wanding techniques.

With the original industrial EPROMs, if the *Y TCL command precedes the *U command in the TCL logic flow, the software will neither acknowledge a no-read nor provide the error code, because the *Y logic only identifies good reads. Altering “Y to accommodate this limitation would prevent upward compatibility of prior TCL applications. The ZON 540 and ZON 541 EPROM 6P2FY370 for code 39 as well as the ZON 530 and ZON 531 EPROM 5P6DY370 for I2 of 5 do allow the error code to be passed from the *Y command to the *U command, and it is expected that other EPROMs to come will behave similarly.

When the terminal’s software detects a no-read, (assuming the “*Y" command does not logically precede the "*U" command and the fourth parameter of "*U" is used), one of the following error codes will appear:

IB There were too many bars and spaces for the input buffer (a maximum of 23 code 39 characters may be read).

1c A bar was too wide or the wand was too slow.

1D There were too many consecutive spots, voids, etc.

IE There was an improper number of bars/spaces.

Page 329 read from a scan by OCR; it may hold reading errors

Standard |2 of 5 Error Codes

Appendix J. Industrial EPROM Bar Code Differences n ores nADOV

IT IV

|W 1X lY

There was an indecisive number of wide spaces for a character.

There was no start character.

There was no stop character.

A start/stop character occurred in the middle of the bar code. The wide space variation was too great.

The wide bar variation was too great.

The narrow space variation was too great.

The narrow bar variation was too great.

There was a poor gap between the wide and narrow spaces. There was a poor gap between the wide and narrow bars. There was excessive ink bleeding.

There was insufficient ink or a poor ribbon.

There was a giant void or spot.

The intercharacter gap (ICG) was too large. (The ICG should be the narrow space width unless a daisywheel-type bar code printer is used. Such printers have the forty-four code 39 bar code patterns in the wheel. This software test is especially valuable for distinguishing the code 39 symbology from the | 2 of 5 symbology.)

There was a check digit error.

There were too many bars and spaces for the maximum character size specified.

There were too few bars and spaces.

Software was adjusting to significant change in wand velocity during a defect (not likely to ever occur).

Characters $/+% are not currently allowed (special option must be chosen for this to occur).

Note: The vertical bar character is part of the error code, but it cannot be entered from the terminal keypad.

The following lists of error codes are available using the fourth parameter of the *U TCL command.

1B

1D m nm wozErRxe

There were too many bars and spaces for the input buffer (a maximum of 40 12 of 5 digits may be read).

There were too many consecutive defects (spots, voids, etc.). There were an improper number of bars/spaces. There was too great a velocity change.

There was no start or stop character.

The wide space variation was too great.

The wide bar variation was too great.

The narrow space variation was too great.

The narrow bar variation was too great.

There was a poor gap between the wide and narrow spaces. There was a poor gap between the wide and narrow bars. There was excessive ink bleeding.

Page 330 read from a scan by OCR; it may hold reading errors

Loose I2 of 5 Error Codes

Example Using 4th Parameter of "*U"

TCL Programmer’s Manual

1Q There was insufficient ink or a poor ribbon.

1S There was a giant void or spot.

1T There was a check digit error.

IU A bearer bar was detected.

IV There were more data characters than the maximum specified. 1X Software was adjusting to significant change in wand velocity | during a defect (this is not likely to ever occur).

lA There was too much inconsistency within a digit pair. 1B There were too many bars and spaces for the input buffer (a maximum of 40 [2 of 5 digits may be read). ID There were too many consecutive defects (spots, voids, etc.). IE There were an improper number of bars/spaces. 1F There was too great a velocity change. 1] There was no start or stop character.

IN There was a poor gap between the wide and narrow spaces. 10 There was a poor gap between the wide and narrow bars.

IT There was a check digit error.

IV There were more data characters than the maximum specified. |W There was a two digit checksum error.

|X Software was adjusting to significant change in wand velocity during a defect (this is not likely to ever occur).

%5E2DU370 ; Example of ZON 530 EPROM version 30=*U PARAMETER 4; ; Idle prompt 40=SCAN BAR CODE;

41=TRY AGAIN; 42=COUNT = ; ; Use #2 for count of consecutive ; no-reads 970=1; ; Select bar code wand ; Begin host key 1 program 100=1; 104=1; 107$ *N#2 ; Put zero in counter #2 P40 ; Display "SCAN BAR CODE" B5.5 ; Select the only source and work ; buffer for program L120 ; Go to memory location 120 120$ G ; Clear the selected destination buffer *U...2 ; input from wand/keypad to destination buffer ; Skip 2 if no-read, but go below if good read *"V.2.6 ; View the selected buffer for 3 seconds L107 ; Go to memory location 107 U50 ; Copy the selected buffer to memory ; location 50 G ; Clear the selected destination buffer *O#2 ; Increment count of consecutive no-reads A42 ; Append "COUNT = " to the destination ; buffer +Q#2 ; Append count to the selected buffer R32 ; Append space to the selected buffer A50 ; Append saved error code to destination ; buffer