The text of a manual · part 25 of 37
TCL Terminal Control Language Programmer's Manual, pages 241 to 250
Pages 241 to 250 of 362
The original document is the PDF (13 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the VeriFone Tranz 330
Page 241
Description:
See Also:
Category:
Buffer Status:
Terminals Supported:
Command Format:
Parameters:
Example:
*Z - Calculate Free Bytes
Calculates the number of free bytes left in RAM and appends the number to the destination buffer.
Command Description +S Get Buffer Size *S Get Memory Size Buffer Operations Source Buffer Destination Buffer No change No change; buffer updated Terminal Special Conditions PNC 330/340 "a" not available XL "a" not available TRANZ 330/340 "a" not available TRANZ 380 "a" available in versions 1.10 and greater
Default Parameter Value Description a 0 Optional; select type of memory in which you would like the terminal to calculate the number of remaining free bytes. 0 = Program memory 1 = Batch memory Command Operation 113$ B5.5 ; Select buffer 5 as both source and destination ; buffer G ; Clear the destination buffer *Z ; Get the number of free bytes available in RAM 24.48.1 ; Pad the number to 4 with leading zeros 11.4.’1000’ ; Skip 1 command if the number of free bytes is ; greater than 1000 L150 ; Jump to control string at memory location 150
5-177
Page 242
5-178
Page 243
Functional Listing of Memory Locations
Terminal Parameters
Appendix A. Memory Locations
Following is a functional listing of the PNC 330/340, XL, TRANZ 330, TRANZ 340, and TRANZ 380 terminal memory locations and a numeric listing for each terminal.
Note: Memory locations for the ZON 53X are the same as for the TRANZ 330; memory locations for the ZON 54X are the same as for the TRANZ 340 with the exception of location 011.
Memory locations for the PNC 330/340 operate the same as the TRANZ
330/340 with the exception of locations 950, 955, 956 and 957. See table on page A-5.
TRANZ 330/340, XL, PNC 330/340
Memory
Location Description Comments
000 Download Phone No. Not available on TRANZ 340 001 Serial Number 004 Program Date 005 Transaction Sequence No. 006 Scroll Length Flag 007 Multiple Trans Timeout 008 Printer Type Flag TRANZ 330/340: Reserved 009 Terminal Key Beep 010 Dial Type Flag Sequence No. Checking TRANZ 340, ZON 54X 011 Dial Speed Flag TRANZ 340: Reserved 012 Parallel Phone Avail. Flag TRANZ 340: Reserved 013 Number of Attempts TRANZ 340: Reserved 014 Telephone Line Test TRANZ 340: Reserved 015 Extended Redial Flag XL 2.80 and higher 950 Printer Type Flag TRANZ 330/340 and PNC 330/340 terminals only 951 Line Feeds for Roll Printer TRANZ 330/340 terminals only 960 Dial-up Line Up/Download TRANZ 330 terminals only Speed TRANZ 340: Reserved
Page 244
TCL Programmer’s Manual
Memory Location Description Comments 970 PIN Pad/Bar Code Wand Port TRANZ 330/340 terminals only 971 Extended Redial Flag TRANZ 330, version 3.40 990 Communications Error Control String TRANZ 330 only 975 Line Recovery Time TRANZ 330 only 979 Abort Control String TRANZ 330/340 only
Buffers Memory Location Description
002 Transmit Buffer 003 Receive Buffer
Miscellaneous Memory Location Description
016 Encrypted Working Key/ Master Key Pointer TRANZ 330/340 019 Application ID 030 Idle Prompt See note, page 5-70, for date/time display 037 Out of Memory Control String XL only
Login Strings/ Function Memory Key Control Strings Location Description
020 Login String #0 021 Login String #1 022 Login String #2 023 Login String #3 024 Login String #4 025 Login String #5 026 Login String #6 027 Login String #7 028 Login String #8 029 Login String #9 031 Function Key #1 032 Function Key #2 033 Function Key #3 034 Function Key #4 035 Function Key #5 036 Function Key #6
039 Function Key #9
Page 245
General Records
Idle Loop
Auto Answer
Appendix A. Memory Locations
Memory Location
040-099 113-199 213-299 313-399
TRANZ 330/340 terminals only: 413-499 513-599 613-699 713-799 813-899 913-949
Memory Location Description
TRANZ 330/340 Terminals only:
980 Idle Loop Control String Delay
981 Idle Loop Control String
982 Idle Loop Phone Number
983 Idle Loop Response Analysis Control String 984 Idle Loop Inactivity Timeout
Memory
Location Description
TRANZ 330 Terminals only:
015 Delay Before Auto Answer
038 Auto Answer Control String
965 Auto Answer Speed
966 Auto Answer Processing
967 Auto Answer Packet Inactivity Timeout
Page 246
Printer Information
Host Parameters
TCL Programmer’s Manual
Memory Location Description
TRANZ 330/340 Terminals only:
950 Printer Type Flag
951 Number of Printer 200 Line Feeds
952 Baud for Generic Roll Printer
953 Data Format for Generic Roll Printer
954 Handshake for Generic Roll Printer
Parameter Memory Location
Transaction Key #1 #2 #3 #4 #5 #6 #7 #8 #9 Primary Phone Number 100 200 300 400 500 600 700 800 900 Secondary Phone Number 101 201 301 401 501 601 701 801 901 Call Center Phone Number 102 202 302 402 502 602 702 802 902 Referral Phone Number 103 203 303 403 503 603 703 803 903 Merchant/Terminal ID 104 204 304 404 504 604 704 804 904 Message Format Flag 105 205 305 405 505 605 705 805 905 Fraud Control Flag 106 206 306 406 506 606 706 806 906 Transaction Control String 107 207 307 407 507 607 707 807 907 Transaction Type Prompt 108 208 308 408 508 608 708 808 908 Floor Limit 109 209 309 409 509 609 709 809 909 Respse Analysis Ctrl String 110 210 310 410 510 610 710 810 910 Auxiliary Control String 111.211 311 411 511 611 711 811 911 Multiple-Trans Group Code 112 212 312 412 512 612 712 812 912
Note: Transaction Key X00-X03 are General Records on TRANZ 340.
Page 247
PNC 330/340
Appendix A. Memory Locations
This matrix illustrates the memory locations and required configuration for the various modes of operation of the PNC 330/340 terminal. Table A-1. PNC 330/340 Modes of Operation
Memory Location/
PNC Mode:
PNC w/Printer Mode:
TRANZ 330 Mode:
Parameter Correct Value Correct Value Correct Value Memory location ignored [2 = Printer 200 0 = No printer (default) 3 = Printer 100/ 150 1=Generic printer 950 5 = Printer 250 2= Printer 200
Printer type flag
(9600 baud)
3= Printer 100/ 150 4 = NCR slip printer 5 = Printer 250 (9600 baud)
955 955 = 0 (PNC) 955 = 2 (PNC with 955 = 1 (TRANZ 330) PNC Operational Mode Default is 0 Printer)
0 = 4800 baud (default) |0 = 4800 baud (default) 956 1 = 1200 baud 1 = 1200 baud Baud for PNC 2 = 2400 baud 2 = 2400 baud Memory location ignored communications with 3 = 4800 baud 3 = 4800 baud remote terminal 4 = 9600 baud 4 = 9600 baud
5 = 19200 baud 5 = 19200 baud 957 0 =’=’ (default) 0 =’=’ (default) Character to Precede 1=" 1=' Memory location ignored
External Magnetic Stripe Reader
Page 248
Terminal Parameters
Buffers
Login Strings and Function Key Control Strings
TCL Programmer’s Manual
TRANZ 380
Memory
Location Description
0000 Download Phone Number
0001 Serial Number
0004 Program Date
0005 Transaction Sequence Number
0006 Scroll Length Flag
0007 Multiple Transaction Timeout
0008 Reserved
0009 Terminal Key Beep
0010 Dial Type Flag
0011 Dial Speed Flag
0012 Parallel Phone Available Flag
0013 Number of Attempts
0014 Telephone Line Test
0017 RECALL, Clock, Unit/Unit Restriction 0019 Application 1D
0030 Idle Prompt
0950 Printer Type Flag
0951 Printer 250 Paper Advance (Number of Line Feeds) 0958 Bell/CCITT Mode
0960 Dial-up Line Upload/Download Speed 0970 PIN Pad/Bar Code Wand Port Function 0975 Line Recovery Time
0977 Free Memory Reclamation Parameter 0985 Host # for Card Initiated Transactions 0986 Host # for Bar Code Initiated Transactions 1000 Date and Time Transfer
Memory
Location Description
0002 Transmit Buffer
0003 Receive Buffer
0018 Error Statistics Buffer
Memory
Location Description
0020 Login String #0
0021 Login String #1
0022 Login String #2
0023 Login String #3
0024 Login String #4
0025 Login String #5
Page 249
General Records
Auto Answer
Idle Loop
Printer Information
Appendix A. Memory Locations
Memory
Location Description 0026 Login String #6 0027 Login String #7 0028 Login String #8 0029 Login String #9 0031 Function Key #1 0032 Function Key #2 0033 Function Key #3 0034 Function Key #4 0035 Function Key #5 0036 Function Key #6 0039 Function Key #9
Memory Locations
0016 0513-0599
0040-0099 0613-0699
0113-0199 0713-0799
0213-0299 0813-0899
0313-0399 0913-0949
0413-0499 1050-1999
Memory
Location Description
0015 Delay Before Auto Answer
0038 Auto Answer Control String
0965 Auto Answer Speed
0966 Auto Answer Processing
0967 Auto Answer Packet Inactivity Timeout Memory
Location Description
0980 Delay Executing Idle Loop Control String 0981 Idle Loop Control String
0982 Idle Loop Phone Number
0983 Idle Loop Response Analysis Control String 0984 Idle Loop Inactivity Timeout
Memory
Location Description
0950 Printer Type Flag
0951 Printer 250 Paper Advance
0952 Baud for Generic Roll Printer
0953 Data Format for Generic Roll Printer 0954 Handshake for Generic Roll Printer
Page 250
Host Parameters
Miscellaneous
Reserved for Future Use
TCL Programmer’s Manual
Note: The following memory locations have been truncated from 4 digits to 3. Each memory location in the table below is preceded by a "0".
Parameter
Memory Location
Transaction Key #1 #2 #3 #4 #5 #6 #7 #8 #9 Primary Phone Number 100 200 300 400 500 600 700 800 900 Secondary Phone Number 101 201 301 401 501 601 701 801 901 Call Center Phone Number 102 202 302 402 502 602 702 802 902 Referral Phone Number 103 203 303 403 503 603 703 803 903 Merchant/Terminal ID 104 204 304 404 504 604 704 804 904 Message Format Flag 105 205 305 405 505 605 705 805 905 Fraud Control Flag 106 206 306 406 506 606 706 806 906 Transaction Control String 107 207 307 407 507 607 707 807 907 Transaction Type Prompt 108 208 308 408 508 608 708 808 908 Floor Limit 109 209 309 409 509 609 709 809 909 Response Analysis Ctrl String 110 210 310 410 510 610 710 810 910 Auxiliary Control String 111 211 311 411 511 611 711 811 911 Multiple-Trans Group Code 112 212 312 412 512 612 712 812 912
Memory Location
Description
0016 0037 0979 0990 0997 0999
Memory Location
Encrypted Working Key/Master Key Pointer
Out of Memory Control String Abort Control String Communication Error Control String VeriFone Control String Programming Error Recovery Log
0955-0957 0959 0961-0964 0968-0969 0971-0974 0976 0978 0987-0989 0991-0996 0998 1001-1049