Page 28

I NSTALLATION Power Up with the Multiport Cable

Connecting to the Ethernet LAN

To connect the Omni 7xxxMPD series terminal to an Ethernet LAN through the 10BaseT port, using a standard Ethernet cable (Figure 24):

1 Insert the LAN cable from the LAN router or hub into the 10Base-T port on the bottom of the Omni 7xxxMPD series terminal.

Figure 24

Connecting to USB Host or Hub

Ethernet Connection

Connecting to a USB host or hub requires a VeriFone USB cable (VPN 22982-xx). To connect to a USB host or hub:

1 Insert the modular plug on the USB cable into the USB jack. 2 Route the cable through the slots to the desired exit side. 3 Plug the other end of the USB cable into the USB host or hub. NOTE

Power Up with the Multiport Cable

The Omni 7xxxMPD series terminal can be connected to an ECR through the USB cable. When connected through a USB cable, the Omni 7xxxMPD series terminal gets power through the USB cable and does not require the multiport cable. This section describes how to connect the Omni 7xxxMPD series terminal to a power source with the multiport cable (see Figure 26). If connected to an ECR, the Omni 7xxxMPD series terminal gets power from the ECR.

CAUTION

Do not plug the power pack into an outdoor outlet or operate the terminal outdoors.

1 Make all other connections before connecting the power pack. 2 Insert the multiport cable connector into the port on the back of the Omni 7xxxMPD series terminal (see Figure 26).

3 Route the cable through the slots to the desired exit side. 4 Affix the cable tie-down strap and secure with screw (Figure 25).

28

OMNI 7XXXMPD SERIES INSTALLATION GUIDE

Page 29

I NSTALLATION Power Up without the Multiport Cable

Figure 25

Plugging in Multiport Cable and Affixing Cable Tie-down Strap

5 Plug the power pack into an indoor electrical power outlet (Figure 26).

Figure 26

Power Pack Connection

If no application is installed in the terminal, the message DOWNLOAD NEEDED displays for a moment, then the main Omni 7xxxMPD series terminal screen displays. An application-specific prompt displays when an application executes.

Power Up without the Multiport Cable NOTE

This section describes about connecting the Omni 7xxxMPD series terminal to a power source when no multiport cable is required.

If connected to an ECR using a USB cable, the Omni 7xxxMPD series terminal gets power from the ECR. Use the following guidelines when Omni 7xxxMPD series terminal connected to power:

1 Make all the cable connections before connecting the power cable. 2 Insert the modular power connector either into the USB or 10Base-T port, whichever is available.

3 Plug the power pack into an indoor electrical wall outlet.

OMNI 7XXXMPD SERIES INSTALLATION GUIDE

29

Page 30

I NSTALLATION Power Up without the Multiport Cable

30

OMNI 7XXXMPD SERIES INSTALLATION GUIDE

Page 31

CHAPTER 3 Maintenance The Omni 7xxxMPD Series Terminal has no user-maintainable parts.

Cleaning the Terminal

To clean the terminal, use a clean cloth slightly dampened with water and a drop or two of mild soap. For stubborn stains, use alcohol or an alcohol-based cleaner. For best results, use a VeriFone Cleaning Kit. For further details refer 02746-01 VeriFone Cleaning Kit.

CAUTION

Never use thinner, trichloroethylene, or ketone-based solvents – they may deteriorate plastic or rubber parts. Do not spray cleaners or other solutions directly onto the keypad or LCD screen.

Smart Card Reader

Do not attempt to clean the smart card reader. Doing so may void any warranty. For smart card reader service, contact your VeriFone distributor or service provider.

OMNI 7XXXMPD INSTALLATION GUIDE

31

Page 32

M AINTENANCE Smart Card Reader

32

OMNI 7XXXMPD INSTALLATION GUIDE

Page 33

CHAPTER 4 Troubleshooting During normal, day-to-day operation of your Omni 7xxxMPD series terminal, it is possible that minor malfunctions can occur. Following are some examples of possible problems, and steps to resolve them. VeriFone follows stringent quality control standards in the manufacture of Omni 7xxxMPD Series terminals. Each unit that leaves the factory receives numerous tests to ensure quality and reliable operation. However, should you encounter a problem in operation, read this section for possible causes and solutions. NOTE

Smart Card

•

Perform only those adjustments or repairs specified in this guide. For all other services, contact your local VeriFone distributor or service provider. Service conducted by parties other than authorized VeriFone representatives may void the product warranty.

•

The Omni 7xxxMPD Series terminal comes equipped with tamper-evident labels. Do not, under any circumstance, attempt to disassemble the terminal.

The smart card implementation is a proprietary hardware solution that has no serviceable parts.

Troubleshooting

The troubleshooting guidelines provided in this section identify various problems and suggest appropriate corrective action(s). If you have problems operating your Omni 7xxxMPD Series terminal, please read through these troubleshooting examples. If the problem persists or if it is not described below, contact your local VeriFone representative for assistance.

Blank Display

The following are the corrective steps taken if the Terminal Display does not show correct or readable information:

1 Check all cable connections. 2 If the problem persists, contact your local VeriFone representative for assistance.

Serial Port Does Not Work

The following are the corrective steps taken if the Serial Port does not work:

1 The serial port on the multiport cable of the Omni 7xxxMPD Series series terminal is identified by the “RS-232” icon. Check that the device connected to the serial port has power and is functioning correctly. If possible, perform a self-test on the device.

2 The cable connecting the optional device to the Omni 7xxxMPD Series terminal serial port may be defective. Try a different serial cable. OMNI 7XXXMPD INSTALLATION GUIDE

33

Page 34

TROUBLESHOOTING Troubleshooting

3 If the problem persists, contact your local VeriFone representative for assistance.

Transaction Fail to Process

The following are the corrective steps taken if the Terminal does not process the transaction: There are several possible reasons why the terminal may not be operating correctly or processing transactions. To check the most likely causes, follow the steps below. Step 1: Check the magnetic card reader

1 Make sure you are swiping cards correctly with the Omni 7xxxMPD Series terminal. The Omni 7xxxMPD Series terminal reader, the black, magnetic stripe on the card should face down and towards the keypad.

2 Perform a test transaction using several different magnetic stripe cards to ensure the problem is not a defective card.

3 Process a transaction manually using the keypad instead of the card reader. If the manual transaction works, the problem may be a defective in card reader. Contact your VeriFone distributor or service provider.

4 If the manual transaction does not work, proceed to Step 3. Step 2: Check the smart card reader

1 Make sure you are inserting the cards correctly with the Omni 7xxxMPD Series terminal smart card reader, the chip on the card should face down and inward.

2 Perform a test transaction using several different smart cards to ensure that the problem is not with the card.

3 Ensure any MSAM cards are correctly inserted and the cardholders are properly secured.

4 If the problem persists, contact your VeriFone distributor or service provider. Step 3: Check the cable connections

1 Ensure that all cables are correctly connected. If cables are connected properly:

2 Check that the cable is in working order by connecting a known good cable. If transactions process with this cable, replace the bad cable.

3 If the problem persists, contact your local VeriFone representative for assistance.

Keypad Does Not Respond

The following are the corrective steps taken if the Keypad does not respond:

1 Check the display panel. If it displays the wrong character or blank when you press a key, follow the steps outlined in Blank Display.

34

OMNI 7XXXMPD INSTALLATION GUIDE

Page 35

TROUBLESHOOTING Troubleshooting

2 If pressing a function key does not perform the expected action, refer to the user documentation for that application to be sure you are entering data correctly.

3 If the problem persists, contact your local VeriFone representative for assistance.

No Response From the Stylus

The following are the corrective steps taken if the terminal does not respond to the stylus inputs:

1 Check the documentation to ensure that the Terminal supports stylus. 2 Unplug the stylus that does not respond, connect a known working stylus (Omni 7100 only).

3 If the problem persists, contact your local VeriFone representative for assistance.

Gap in Captured Signature

The following are the corrective steps taken if there is a gap in captured signature:

1 Ensure that the stylus is pressed hard during signature capture. 2 Replace Signature Capture module with new or known good module. 3 If the problem persists, contact your local VeriFone representative for assistance.

No Response From the Touch Panel

The following are the corrective steps taken if the Touch Panel does not respond or incorrect response.

1 Make sure you power off and power on.

NOTE

Keep your hands away from the Touch Panel while terminal powers up.

2 Replace Signature Capture module with new or known good module. 3 If the problem persists, contact your local VeriFone representative for assistance.

OMNI 7XXXMPD INSTALLATION GUIDE

35

Page 36

TROUBLESHOOTING Troubleshooting

36