Page 21

TERMINAL S ETUP Connect Terminal Power Pack

Figure 14

Omni 37xx Power Pack Connection

•

To lock the connector into the power port, align the plastic lock tab so it points up. Insert the connector, then twist it to the left.

•

To unlock the connector, twist it to the right.

2 Insert the power cable into the power pack. 3 Plug the power pack cable into a wall outlet or surge protector. WARNING

NOTE

Do not plug the power pack into an outdoor outlet or operate the terminal outdoors. Also, disconnecting power during a transaction may cause transaction data files that are not yet stored in terminal memory to be lost.

To protect against possible damage caused by lightning strikes and electrical surges, consider installing a power surge protector. When the terminal has power, the LCD screen lights and the green LED indicator flashes on and off if the printer has no paper, or stays lit if paper is loaded. If an application is loaded in the terminal, it starts after the initial VeriFone copyright screen and displays a unique copyright screen. If no application is loaded in the terminal, DOWNLOAD NEEDED appears on screen after the initial VeriFone copyright screen.

OMNI 37XX INSTALLATION GUIDE

21

Page 22

TERMINAL S ETUP Routing The Cables Using Wire Clips

Routing The Cables Using Wire Clips

Since the Omni 37xx terminal is a hand-over solution, make sure the cables are routed loosely. Use the two wire clips provided with each terminal to organize loose cables. See Figure 15.

Figure 15

Routing Cables Using Cable Wires

1 Place the telephone cord and power cable into the grooves inside the wire clip.

2 Close the wire clip and press the halves together until the it snaps closed. 3 Unsnap the wire clip, to reposition as necessary.

Smart Card Transaction

The smart card transaction procedure may vary from one application to an another. Verify with your application provider before you perform a smart card transaction. To Conduct a Smart Card Transaction

1 Position a smart card with the contacts facing upward (see Figure 16). 2 Insert it into the smart card reader slot in a smooth, continuous motion until it seats firmly.

22

OMNI 37XX INSTALLATION GUIDE

Page 23

TERMINAL S ETUP Magnetic Card Reader Use

3 When the LCD screen indicates the transaction is completed, remove the card.

Figure 16

Inserting the Smart Card

CAUTION

Leave the smart card in the card reader until the transaction is completed. Premature removal invalidates the transaction.

Magnetic Card Reader Use

To Conduct a Credit/Debit Card Transaction

1 Position a magnetic card with the stripe facing down and inward, toward the keypad.

2 Swipe it through the magnetic card reader (see Figure 17).

Figure 17

Using the Magnetic Card Reader OMNI 37XX INSTALLATION GUIDE

23

Page 24

TERMINAL S ETUP Magnetic Card Reader Use

24

OMNI 37XX INSTALLATION GUIDE

Page 25

CHAPTER 3 Specifications This chapter discusses power requirements, dimensions and other specifications of the Omni 37xx terminal.

Power

Omni 37xx terminal: 24 V DC; 1.5 A

DC Power Pack

For Non-switching Power Supplies:

•

UL, ITE Listed, Class 2 Power Supply

•

Input rated: 110 - 127V ac, 60 Hz.

•

Output rated: 24V dc 1.5 A

For switching Power Supplies:

•

UL, ITE Listed, Class 2, Switching Power Supply

•

Input rated: 100 - 240 V ac, 50/60 Hz.

•

Output rated: 24 V dc, 1.5 A

Barrel Connector Polarity:

Temperature

External Dimensions

Weight

•

Operating temperature: 0° to 40° C (32° to 104° F)

•

Storage temperature: -18° to + 66° C (0° to 150° F)

•

Relative humidity: 15% to 90%; no condensation

•

Length: 210 mm (8.3 in)

•

Width: 104 mm (4.1 in)

•

Depth: 83 mm (3.3 in)

•

Weight: 760 gms (1.675 lb)

Terminal unit weight: 1.28 kg (2.82 lb) Shipping weight: 3.26 kg (7.19 lb) The shipping weight includes: shipping carton, terminal, power pack and cable, telephone line cable, one Omni 37xx Certifications and Regulations, and one Omni 37xx Quick Installation Guide.

OMNI 37XX INSTALLATION GUIDE

25

Page 26

S PECIFICATIONS

26

OMNI 37XX INSTALLATION GUIDE

Page 27

CHAPTER 4 Maintenance The Omni 37xx has no user-maintainable parts.

Cleaning the Terminal

CAUTION

To clean the terminal, use a clean cloth slightly dampened with water and a drop or two of mild soap. For stubborn stains, use alcohol or an alcohol-based cleaner. For best results, use a Verifone Cleaning Kit (refer to the Accessories and Documentation section). Never use thinner, trichloroethylene, or ketone-based solvents – they may deteriorate plastic or rubber parts. Do not spray cleaners or other solutions directly onto the keypad or LCD screen.

Smart Card Reader

Do not attempt to clean the smart card reader. Doing so may void any warranty. For smart card reader service, contact your VeriFone distributor or service provider.

OMNI 37XX INSTALLATION GUIDE

27

Page 28

M AINTENANCE Smart Card Reader

28

OMNI 37XX INSTALLATION GUIDE

Page 29

CHAPTER 5 VeriFone Service and Support For Omni 37xx terminal problems, contact your local VeriFone representative or service provider. For Omni 37xx product service and repair information:

Returning a Terminal for Service NOTE

•

USA – VeriFone Service and Support Group, 1-800-834-9133, Monday - Friday, 8 A.M. - 7 P.M., EST

•

International – Contact your VeriFone representative

Before returning the Omni 37xx terminal to VeriFone, you must obtain a Merchandise Return Authorization (MRA) number. The following procedure describes how to return one or more Omni 37xx terminals for repair or replacement (U.S. customers only): International customers, please contact your local VeriFone representative for assistance with your service, return, or replacement.

1 Gather the following information from the printed labels (see Figure 18) on the bottom of each Omni 37xx terminal to be returned:

•

Product ID, including the model and part number. For example, “OMNI 3700” and “PTID xxxxxxxx”

•

Serial number (S/N xxx-xxx-xxx)

2 Within the United States, call VeriFone toll-free at 1-800-834-9133. 3 Select the MRA option from the automated message. The MRA department is open Monday–Friday, 8 A.M.–7 P.M., EST.

4 Give the MRA representative the information gathered in Step 1. If the list of serial numbers is long, you can fax the list, along with the information gathered in Step 1, to the MRA department at 502-329-5947 (U.S.)

•

Please address the fax clearly to the attention of the “VeriFone MRA Dept.”

•

Include a telephone number where you can be reached and your fax number.

•

You will be issued MRA number(s) and the fax will be returned to you.

OMNI 37XX INSTALLATION GUIDE

29

Page 30

VERI F ONE S ERVICE AND S UPPORT Accessories and Documentation

NOTE

One MRA number must be issued for each Learning Products Template Version 2.1 terminal you return to VeriFone, even if you are returning several of the same model.

5 Describe the problem(s) and provide the shipping address where the repaired or replacement unit must be returned.

6 Keep a record of the following items: •

Assigned MRA number(s).

•

VeriFone serial number assigned to the Omni 37xx terminal you are returning for service or repair (terminal serial numbers are located on the bottom of the unit (see Figure 18).

•

Shipping documentation, such as air bill numbers used to trace the shipment.

•

Model(s) returned (model numbers are located on the VeriFone label on the bottom of the Omni 37xx terminal).

SERIAL NUMBER

MODEL NUMBER

Figure 18

Accessories and Documentation

Information Label on Terminal Bottom

VeriFone produces the following accessories and documentation for the Omni 37xx terminal, as listed below. When ordering, please refer to the part number in the left column. VeriFone Online Store at www.store.verifone.com

•

USA – VeriFone Customer Development Center, 800-233-0522, Monday - Friday, 7 A.M. - 5 P.M., MST

•

International – Contact your VeriFone representative

Download Cables

Cables for Optional Peripherals 30

OMNI 37XX INSTALLATION GUIDE

05651-xx

MOD10-MOD10 (terminal-to-terminal)

26263-xx

02xxx MOD10-PC DB25F (terminal-to-PC)

26264-xx

02xxx MOD10-PC DB9F (terminal-to-PC)

07041-xx

MOD10-MDIN9 (CR 600/CR 1000i check readers; P250/P355/P900 external printers)

07042-xx

MOD10-4P4C (all VeriFone PIN pads)