The text of a manual · part 7 of 7
PT-805 User's Manual, pages 61 to 70
Pages 61 to 70 of 70
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Unitech PT815
Page 61
6.1
Chapter 6 Built-In Keyboard Wedge
Installation
The PT-805 provides two convenient ways to upload your data to a computer. A RS232 standard interface is the conventional method. But, some user’s application programs do not support RS232 input driver. The PT-805 provides you the another way to send your collected data to your application program through the keyboard port. It is the simplest way to work with your program.
There are two parts to install PT-805 as a keyboard wedge.
e PT-805 Keyboard Wedge Adapter e One of the following cables
- PC/AT Adapter Cable P/N# 155102-0050 - PS/2 Adapter Cable P/N# 155102-0080
In order to install properly before use, please refer to following steps.
Step 1: Step 2:
Step 3:
Step 4:
Turn off your computer first. Unplug your keyboard connector from computer keyboard port., Connect the proper Adapter Y-cable between keyboard and computer.
Plug the Keyboard Wedge Adapter into the Adapter cable DB-25 connector. It does not need any external power. Please refer to the following diagram.
-57-
Page 62
=> Keyboard Port oo PC \a/ Keyboard Wedge | Adapter To PT-805 RS232 Port
Step 5: Plug the Keyboard Wedge Adapter DB-9 connector into the PT-805 RS232 port.
Step 6: Power up your PC. Your application program will run as usual.
Step 7: Set the PT-805 Comm Port parameter as a ”AT/PS2” in “Set Comm” of Supervisor mode. The PT-805 is ready to send now.
6.2 Uploading Data to PC/AT or PS/2
Ready Mode In Ready Mode, user can operate the PT-805 built-in keyboard wedge function as an input device. The scanning data or keyed-in data will be sent to the PC right away and displayed on the PT-805’s LCD. But, this data will not be stored in the PT-805 memory.
If your computer misses characters from the PT-805, you may need to increase the interdelay ( inter-character delay ). See “Section 4.9.3 Communication Parameters Setting”.
- 58 -
Page 63
Send Mode of XRANS
The PT-805 can also send collected data to a PC through the keyboard port. Press the[XRANS] key, the PT-805 will prompt “Communication Send? (Y/N)”. Then press [(YES)] key to start uploading data to PC.
If your computer misses characters from the PT-805, you may need to increase the interdelay ( inter-character delay ). See “Section 4.9.3
Communication Parameters Setting”.
NOTE After uploading, please unplug the PT-805, but leave the Keyboard Wedge Adapter and the adapter cable connected together. Otherwise, your keyboard will not work.
-59-
Page 64
Appendix A : Built-In Diagnostic Program
The PT-805 supports a diagnostic program to verify the terminal itself. When there has been a service procedure on the H/W or S/W, such as maintenance, repair or upgrade, the system should be verified by executing this diagnostic program. It supports several routines to check the LCD, keypad, RS-232 port and Memory. It should be noted that the diagnostic program will destroy any data in the PT-805. Hence, before using the diagnostic program, make sure you have saved all data. To enter diagnostic mode, using "SYSTEM RESET":
1. Turn off the PT-805.
2. Press the [EXIT], the [/ P) and the [ON/OFF] keys simultaneously. 3. Press the [(YES)] to reset the terminal.
Then a diagnostic program request message will be displayed on the LCD:
< DIAGNOSTIC > (Y/N)?
Press [(YES)] to enter this mode or [(NO)] to exit the diagnostic function and return to the “Ready Mode". If you choose [(YES)], the LCD will be displayed:
1-LCD 2-KBD 3-232 4-MEM
Press [EXIT] to exit the diagnostic function and return to the "Ready Mode".
LCD verify
Choose the option "1-LCD" from the diagnostic menu to test the LCD. The LCD will display 32 characters of all printable characters (ASCII 32 to 127). Any inconsistencies shown on the screen indicates a defective LCD.
C1 Pere rere eeree)t
- 60 -
Page 65
KEYPAD verif: If the keypad verify routine "2-KBD" is chosen, Any key pressed will be shown on the LCD. For example, if you press the [ENTER] key:
> KEYPAD TEST < Key->ENTER
To exit this mode, press [EXIT] then [(YES)].
RS-232 verif To test the RS-232 port, the user will have to loop back (connect pins 2 and
3) first, and then press any key to start verification. The LCD will show "RS- 232 OK" if the test passed. Otherwise, an error message "RS-232 ERR" will be displayed.
> RS232 TEST < RS-232 OK
Memory verify When selecting the “4-MEM” to verify memory function, the LCD will show
<<MEMORY TEST>> Bankx OK
Where x is from 3 to 0.( 64K Bytes each Bank). The memory size depends on the users order. After testing of all banks, the PT-805 starts the memory backup testing. First a fixed pattern of data is stored into RAM memory, then the PT-805 turns itself off and waits for the user to turn it on again to verify the backup memory. After turning on the PT-805 again, the LCD will show the message below when memory backup test is passed.
--~- BACKUP OK---
If memory test indicates an error, please contact your local sales or service representative.
-61-
Page 66
Appendix B: Error Messages
@ = «Error at MACRO: nnn Pre-Form. A tun time error occurred at the nnnth line macro of the pre-form process. Correct the pre-form process macro in Job Generator.
@ = Error at MACRO: nnn Pre-Fid. A tun time error occurred at the nnnth line macro of the pre-field process. Correct the pre-field process macro in Job Generator.
B= Error at MACRO: nnn Verifica. A run time error occurred at the nnnth line macro of the verification process. Correct the verification process macro in Job Generator.
m= =Error at MACRO: nnn Post-Fid. A run time error occurred at the nnnth line macro of the post-field process. Correct the post-field process macro in Job Generator.
@ = Error at MACRO: nnn Post-Form. A run time error occurred at the nnnth line macro of the post-form process. Correct the post-form process macro in Job Generator.
S = Time out error. The PT-805 did not receive data from the RS-232 port within a predetermined amount of time. Check the RS-232 connection and communication parameters. Verify it matches the correct parameters.
@ Format unmatched. User has entered a field length that is out of range or the wrong characters. -62-
Page 67
Write failure. The Memory has a bad sector(s) or the Memory is full.
Create failure. Failed to created a form in the PT-80S ROP. This will happen if the user tries to re-modify the ROP form format setting when the PT- 805 ROP has stored input data. It should be purged of all ROP data before re-configuring the ROP form format.
Buffer Overflow. PT-805 detected a buffer overflow error while receiving data from RS-232 port. Add a flow control, XON/XOFF in your program on the host or PC. Decrease the baud rate.
JOB error. PT-805 found erroneous data in a JOB while downloading.
Check the JOB and the communication parameters.
DATA error. PT-805 received incorrect data while downloading a JOB which included data file. Check the format of the included data file to see if it matches the corresponding form’s format.
Record length exceed 256. The record length setting of ROP exceeds 256 characters or error setting. Re-enter the correct range length.
Parity error. PT-805 received an error character frame parity while in communication. Check the communication parameters and connection. Verify that they match the set value.
-63-
Page 68
Protocol error. PT-805 received an error control character while in communication.
Check the communication parameters. Verify that they match the set value.
Memory full. PT-80S has no free memory for storage. Upload your data to host or PC and purge it.
-64-
Page 69
Appendix C : Specifications
Memory: - ROM: 64K Byte for ROP (Resident Operation Program) - RAM: 64 / 128/ 256K Byte CMOS SRAM
Display: - 2 line x 16 characters standard LCD with 5 x 7 dot matrix characters
Keypad: - 35 key membrane keypad
Power Supply:
- Main Battery: - NiCd rechargeable 700 mAH battery pack - 4 AA-size Alkaline batteries
- Backup battery: - CR2032 3V 190 mAH Lithium battery
Power Consumption: - Operating voltage: +5V + 10% - Operating current: 30 mA , scanner excluded
Operating Environment: - Operating Temperature: 0°C - 50°C (32°F - 122°F) - Storage Temperature: -20°C - 70°C ( -4F - 158'F ) - Humidity: 5 - 95% RH
V/O Connectors:
- +9V DC adapter (for NiCd battery charging)
- DB-9 Squeeze type scanner Port
- DB-9 male RS-232/Keyboard Wedge Box interface port.
Weight: - 470 g (16.5 oz with batteries)
Dimension: -LxWxH= 90 x 203 x 45 (mm) = 3.54 x 7.99 x 1.77 (inches)
-65-
Page 70
Appendix D: Pin Assignment of Connectors
(a) Battery Charging Jack Pin No. Signal 1 (Center) +9 VDC 2 GND
(b) Scanner Port
= s 4 iS
Signal
(1 )Start of Scan (1 )Bar Signal
(O )Good Read N.C.
(1) Switch Trigger (O )Power Enable GND
GND
(0 )+5V DC oO Oo COIDNEWNE
(c) RS-232 Port
= s Zz ©
Signal
(1)+9 VDC Input (I)RXD (O)TXD (O)DTR
GND
N.C.
(O)RTS
(I)CTS
(1)RI
(eo) Oo CHADNEWNHE
- 66 -