The text of a manual · part 5 of 7
PT-805 User's Manual, pages 41 to 50
Pages 41 to 50 of 70
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Unitech PT815
Page 41
4.9.1 Auto Boot Setting
The user can define an auto-booting program when powering up the terminal. When the PT-80S is turned on, if there is an auto-booting program assigned, this designed program will be executed directly without entering any key. After selecting Auto Boot ,use the [(NO)] key to sequence through the available forms, then press the [(YES)] key to confirm.
Auto Boot FORM: ROP
4.9.2 Date & Time Setting
The PT-805 supports a "Real-Time Clock (RTC)". The clock can be used for ’ the "Time Stamping” function, which adds date and time information after each record. To stamp date and time after a record, refer to Section 4.9.5 ROP Data Format Setting. Press [(YES)] key when PT-805 prompts “Set Date & Time? (Y/N)”. The message:
Date: 01/01/94 00/00/00 will be displayed on the screen. The first line is the current date with the format MM/DD/YY (Month, Day, Year). Enter the month, day, and year as prompted on the second line. For example, to set the date: June, 25, 1994, enter the key sequence: [0][6]{2][5][9][4]. To bypass the setting, press the [ENTER] key.
After the date is set, the time will be displayed:
Time: 08:30:01 00:00:00
The first line displayed is the current time in the PT-805 expressed in the 24 hour system with the format hh:mm:ss (hour, minute, second). In the same way, enter the correct time or just press [ENTER] to bypass the setting or [EXIT] key to exit Time setting.
- 37.
Page 42
Set Auto off Timer After setting the RTC, the following message will be displayed:
Auto off:Disable
Press the [(NO)] key to toggle Enable or Disable Auto off function and press the [(YES)] key to confirm the setting. If Auto off function is Enable, the following message will displayed:
Auto off:Enable Period:3
It is then possible to set the timer value which specifies the duration before the PT-805 automatically shut off its power. The valid timer setting is from 1 to 30 minutes, by the minute. User may enable the Auto off function and set timer to 5 minutes, then when PT-805 is in use the power will automatically shut off after the PT-805 no has operation for a duration of 5 minutes. Turning off the power of PT-805 through Auto off function is the same as turing it off by pressing the [ON/OFF] key. In any event, any use of PT- 805, such as bar code scanning, pressing any key, or data input through the RS-232 port will automatically cause the timer to begin a new 5 minute counting cycle. For example, if the PT-805 is not in use for 3 minutes and the operator presses the [ENTER] key, then PT-805 will once again start a 5 minute counting cycle for CPU idle time.
4.9.3 Communication Parameters Setting To send data to the computer or receive a program from the computer, it is necessary to set the communication parameters for the PT-805. Press [CYES)] key when PT-805 prompts as follow:
Set Comm? (Y/N)
The Settings for communication are:
- 38 -
Page 43
Comm Port Select as a RS232 or AT/PS2 function
Baud Rate Communication speed.
Data Bit Data format in communication.
Parity Parity check.
CTS/RTS Hardware handshaking.
Protocol Protocol between PT-805 and computer.
Send EOF Disable/Enable to attach EOF, 1A hex, when Protocol set to off.
Header Disable/Enable transmitting header of a file.
Interdelay Time delay between fields during RS232 function or time delay between character during AT/PS2 wedge function.
Comm Port ;
There are two methods to upload PT-805 data to PC. One is the RS232 port ,another is the PC/AT or PS/2 keyboard port. Please refer to Chapter 6 Built-in Keyboard Wedge for installation and operation.
Comm Port:RS232 --> RS232,AT/PS2
Press [(NO)] key to toggle the desire function, then press [(YES)] key to confirm:
Baud Rate
This option sets the communication speed measured in bits per second (bps). The PT-805 supports baud rates of 300, 1200, 2400, 4800, 9600, 19200. It must be set to the same value the computer is using. Press [(NO)] key to toggle the desire baud rate, then press [(YES)] key to confirm:
Baud Rate: 9600 --> 300,1200, 2400, 4800, 9600,19200.
Data Bit
The Data Bit option sets the characters sending to 7 or 8 bits per frame. This option must be set to the same value as the computer. Use the [(NO)] key to choose 7 or 8 from the screen after the baud rate is set, then press [(YES)] key to confirm your selection.
- 39.
Page 44
Data Bit :8 --> 7,8
Parity
Parity is used to increase the reliability of communication. The PT-805 supports even, odd, mark, space and none parity check. Use the [(NO)] key to choose these options from the screen after the data bits is set, then press [CYES)] key to confirm your selection. Choose an option after Data Bit is set.
Parity :none --> even, odd,mark, space none
CTS/RTS
The CTS/RTS setting is for handshaking between the PT-805 and the computer while sending characters. The difference between protocol and CTS/RTS setting is that the first one is handshaking for file transfer and the second is for characters. The CTS/RTS is usually used for hardware handshaking during character transfer. If you are using an IBM PC or some other compatible machine the CTS/RTS should be set to off. Use the [(NO)] key to choose these options from the screen after the header is set, then press [CYES)] key to confirm your selection.
CTS/RTS :off -~>on, off
Protocol
Protocol is used for software handshaking between the PT-805 and the computer while sending a file or program. It needs to be set to ON while using the UNITECH's communication utility program - Job Generator, and set to off while using a dummy receiving program. Use the [(NO)] key to choose these options from the screen after the parity is set, then press [(YES)] key to confirm your selection.
Protocol :on -->on, off
If the user wants to write his own communication program to receive data. from PT-805, then the "off" protocol selection is suggested. For writing such, a program, refer to Chapter 5 Interfacing And Communications. For detailed
- 40-
Page 45
information about protocol definition, also refer to Section 5.3 Communication Data Format and Protocol.
Send EOF
The Send EOF setting is only available when Protocol is set to off. When Send EOF is set to on, an EOF code, 1A hex (CTRL-Z),will be appended to the end of data file uploaded from PT-805 to a Host computer.
Send EOF :on -->on, off
Header
A Header is added before each data packet is transferred to the computer from the PT-805. It includes file name and current date. and time information. If you are using UNITECH's communication utility program - Job Generator, set this option to ON. Use the [(NO)} key to choose these options from the screen after the protocol is set, then press [(YES)] key to confirm your selection. Detailed descriptions of the definition of a header can be found in
Chapter 5 Interfacing And Communications.
Header : on -->on, off
Interdelay(ms)
Comm Port is set to RS232
The Interdelay setting is used to set a time delay in milli-seconds between data fields transmitted from the PT-805 to the Host computer, if the Comm Port is set to RS232. When Protocol is set to off, this setting may be needed to keep pace of data uploading and make sure the receiver has enough time to process the data.
Comm Port is set to AT/PS2 The Interdelay setting will be used to set the time delay between character transmission from the PT-805 to a PC/AT or a PS/2 keyboard port.
Interdelay(ms): 1 (e} -->0 - 32767 ms
-41-
Page 46
4.9.4 Bar Code Setting
Press [(YES)] key when PT-805 prompts as follow:
Set Bar Code? (Y/N)
Disable/Enable Bar Code Reading The PT-805 can read many bar codes simultaneously. However, allowing many bar codes will decrease the reading rate. To increase the reliability of reading labels, codes that are not used should be disabled.
The PT-805 provides a rich set of major bar code symbologies. The user can select the attributes of each bar code symbology. Use [(NO)] key to toggle the “on” or “off” option for each switch, then press [(YES)] key to set the bar code attributes as follows:
@ UPC/EAN group
UPC/EAN on: Enable UPC/EAN group reading off: Disable UPC/EAN group reading
UPC-A=EAN on: Output UPC-A code 13 digits off: Output UPC-A code 12 digits
Send First on: Send leading digit off: Strip leading digit
Send Last on: Send the last digit off: Strip the last digit UPC-E=UPC-A on: Expand UPC-E to UPC-A code off: Output UPC-E code
@ CODE 39 group CODE 39 on: Enable CODE39 group reading off: Disable CODE39 group reading Cal CDV on: Enable CDV off: Disable CDV Full ASCII on: Enable Full ASCII CODE39 off: Disable Full ASCII CODE39 Send CDV on: Send the CDV digit off: Strip the CDV digit @ Interleaved 2 of 5 group 12 OF 5 on: Enable I2 OF 5 group reading
- 42 -
Page 47
Cal CDV Send First Send Last @ CODABAR group . CODABAR Cal CDV Start/Stop Send CDV
® MSI group MSI
@ CODE 128 group CODE 128 off: Disable 12 OF 5 group reading on: Enable CDV off: Disable CDV on: Send the leading digit.
off: Strip the leading digit.
on: Send the last digit off: Strip the last digit on: Enable CODABAR group reading off: Disable CODABAR group reading on: Enable CDV off: Disable CDV on: Send the leading and last digit. off: Strip the leading and last digit.
on: Send the CDV digit off: Strip the CDV digit on: Enable MSI group reading off: Disable MSI group reading on: Enable CODE 128 group reading off: Disable CODE 128 group reading
4.9.5 ROP Data Format Setting, The ROP form can be created using the format option in the “1-SETUP* of Supervisor Mode. The following parameters can be set to control the built-in data collection application.
Field Number Prompting Message Picture
Min. Length
Max. Length
ROP Echo
Delay after entry Field Delimiter Record Delimiter
How many fields for a record. Message for the user.
Verify the enter data.
Minimum length of a field. Maximum length of a field
Echo data to computer.
Delay display time after data entry. Delimiter between fields. Delimiter between records.
- 43-
Page 48
@ Time Stamp, Stamp time after record. @ Long Format Format of time stamp. Press [(YES)] key when PT-805 prompts as follow:
Set Data Format? (Y/N)
NOTE The user cannot modify the ROP form format setting when the PT- 805 ROP has stored input data. Otherwise, the error message "Create failure." will be displayed. User will have to purge the data before modifying data format settings.
Field Number After pressing the [(YES)] key from the above message. The screen will display:
How many fields? 1 --> 1 - 16
Enter the total number of fields used in a record. For example, if the application has three fields, "ITEM", "QUANTITY", and "CUSTOMER", then enter 3 followed with the [ENTER] key. After you enter the number of fields, the PT-805 will request the prompting message, picture, and length for each field.
Prompting Message The prompting message is requested after the field number is entered:
#1 Fld.Prompt
--> 16 characters (max.)
Enter the prompting message , for example - "ITEM:". All alphanumeric characters are supported for the message.
Page 49
Picture
After the prompting message, the picture is requested by the PT-805. A picture is a sequence of characters that verify the entered data and format it. The screen for picture entering is:
#1 Fld.Picture : --> 32 characters (max.)
Table 4-4 lists available picture characters used with the ROP. Each lowercase character represents different data qualification attributes. Characters not listed will be treated as constant characters which will be displayed on the screen. The picture characters will be Goplayed as ‘C' (small box) on the screen during data collection.
Table 4-4 Available Picture Characters
Description
Only alpha characters are accepted. (A-Z,a-z)
Only digits 0-9 , dot (‘.”), negative(‘-’) and positive(‘+’). Only digits 0-9.
Only lower case alpha characters. (a-z)
Only upper case alpha characters. (A-Z)
Printable characters. (ASCII code 32 to 127)
Full ASCII characters.
Control character used to append constant string. Control character used to remove characters.
HLN KEK VB &
For example, if you define a picture : “ppp-pppp" and the prompting message, for example, is "TEL:", then during input, the screen will show this:
TEL: 000-0000
The characters entered will pass only if they are one of the digits, 0-9 (Since the picture character 'p' only accepts digits). Any illegal character will be ejected by the picture function and will cause the system to beep. The character, '~', in this example, is used for display purposes only.
- 45 -
Page 50
Control Characters in Picture
Constant characters like the dash '-’ in the above example can be included as part of the data. To include constant characters add the control picture character, '%', at the beginning of a picture. For example, the picture : "%ppp-pppp" when entered (for example, "5962300") will include the constant character '-' in the data ("596-2300"). The purpose of the control character '%' is for appending some constant characters automatically to a string of data. Table 4-5 lists examples of applying different pictures to data entry and the results.
NOTE Note that the '%' control character only can appear at the beginning of a picture.
In Table 4-5, column 1 defines the picture used, column 2 is the screen display, column 3 is the data entered, and the last column shows the data stored. Another control character is '#', which is used to remove unneeded characters. It is sometimes used to mask the start/stop character of a label, since some bar codes have unnecessary start/stop characters. The '#' control character can appear anywhere in a picture.
Table 4-5 Examples of pictures
Picture Screen Data Entry Result Ppp-pppp 000-0000 5962300 5962300 %ppp-pppp 000-0000 5962300 596-2300 aaa-aaaa 000-0000 5962300 rejected #pp-ppp# 000-0000 5962300 96230 aa#aaaa o000000 UNITECH UNTECH #HH-2222 000-0005 5962300 2300 On ____ Field Length .
The purpose of the field length setting is to verify the width of data entered. After the picture data is entered the screen will display: .
- 46-