Page 21

To check for barcodes already loaded (PT -815) 1 Press the MENU key to display the portable unit’s Main Menu. 2 At the Main Menu, select 2–STAT. The portable unit displays the Status screen. There are many different statistics that you can see here, but only one you need to pay special attention to at this time - the number of records stored in the ROP. 3 Press the ENTER key repeatedly until Form #1: ROP appears on the screen. Look at the number of records shown under Form #1: ROP. This is the number of records stored in the ROP. If this number is anything other than 0 (zero) and you’re not sure if they’re inventory barcodes, don’t enter new barcodes in the portable unit’s ROP. You may need to either upload or purge them first. Purge the barcode data only if it has already been uploaded or is no longer needed. If you’re certain that any barcodes currently stored in the ROP are for inventory, and you want to add to these barcodes, you can scan more barcodes. 4 Press the EXIT key to exit the status check.

Entering barcodes into the portable unit You can enter barcodes into the portable unit with the keypad or by scanning them. After you enter the barcodes into the portable unit, you upload the barcodes to the computer that has Spectrum CIRC/CAT installed. Note: The maximum barcode length that the portable units will accept is 24 characters.

To enter barcodes into the portable unit (PT -815) 1 Press the MENU key to display the portable unit’s Main Menu. 2 Select 1–INPUT. The portable unit displays a screen listing the programs loaded on the portable unit. 3 Select 1–ROP. Barcode data for inventory is stored in the portable unit’s ROP. The portable unit displays the Enter Barcode screen (the user-defined prompt set up in the format settings).

Troubleshooting on the portable unit PortInvCirc 1Amn Aug99 krn/jrr

21

Page 22

4 Scan barcodes or type them on the keypad and press the ENTER key. Winnebago recommends that you upload the barcodes to your computer after about every 1000 barcodes. You can enter about 7000 scans or until the memory is full; however, it’s best to upload to the computer before reaching the portable unit’s memory limit. When you reach the memory limit, you can't upload data (because of insufficient memory) and you must delete the barcodes in your portable unit. 5 When you’ve finished scanning barcodes, press the EXIT key. The portable unit displays a message to verify whether you want to exit. 6 Press the YES key to exit the ROP. Then press the EXIT key again to return to the Main Menu.

Uploading barcode data to the computer 1.

Plug the RS-232 cable into the USB port.

2.

Connect the USB port to your Macintosh computer.

3.

On your Macintosh computer, open Simple Text.

4.

On your PT815, press the Menu key.

5.

Select 3 – Send from the Main menu.

6.

At the “Send ROP” prompt, press the YES key. The barcodes are uploaded into the word processing document you opened in step 3.

7.

When all of the barcodes are entered into Simple Text, press the EXIT key on your portable unit. The unit displays a message to verify that your want to exit.

8.

Press the YES key. Then press the EXIT key to return to the Main Menu and press EXIT again to return to the Ready prompt on your portable unit.

9.

On your Mac, choose Save from the file menu.

10. Click the Desktop button.

22

Spectrum® Portable Circulation and Inventory 4/8/2002

Page 23

11. Click on the NEW button. Name the new folder Inventory and click Create . You only do this step the first time you save an uploaded file. 12. Name your file Hist1.txt. (Each succeeding file should be called Hist2.txt, Hist3.txt, etc.). 13. Click Save. 14. Start your Spectrum program. 15. From the Winnebago menu, choose Inventory. The Inventory window opens. 16. Select Step 2 from the list and click Next. The Entering Barcodes for Inventory windows opens. 17. Select Enter barcodes from a text file and click Next. The Entering Barcodes from Text Files window opens. 18. Click Add. 19. Locate and double-click the Inventory folder that you created. 20. Choose Hist1.txt. 21. Click Next to begin processing the barcodes in the text file.

It is important that you keep the files numbered differently. That way if you need to redo something you won’t have to rescan. I would keep all the files until I am completely done with the inventory and then trash them.

Purging inventory barcode data After you upload the barcode data, you can clear that barcode data from the portable unit. The barcodes that you scanned for inventory are stored in the portable unit’s ROP. By following the steps below, you can safely delete the ROP data without affecting other data that you may have stored on the portable unit, such as circulation data. Important! This process deletes all barcode data stored in the portable unit’s ROP, so be sure that the barcodes uploaded properly before you purge.

To purge inventory data (PT-815) 1 Press the MENU key to display the portable unit’s Main Menu. 2 Select 6–PURGE. The portable unit displays the Purge Data screen. Pay special attention to the prompts on this screen. 3 At the ROP prompt, press the YES key. Troubleshooting on the portable unit PortInvCirc 1Amn Aug99 krn/jrr

23

Page 24

4 If the portable circulation program is loaded, the CIRCULAT prompt appears. Press the NO key. A message appears on the screen to inform you that the ROP data has been deleted. 5 Press any key on the portable unit to exit the Purge mode. 6 You can exit to the Ready prompt and shut the unit off.

Troubleshooting on the portable unit If these solutions don’t correct the problem, please call the Winnebago Customer Support Department at 1-800-654-3002.

Problem: The portable unit behaves abnormally. Solution: Perhaps the unit has been used improperly. Inconsistent data may also occur if your batteries are low on power. You may want to reset the unit.

Problem: The portable unit displays no message and emits no beep, or its LCD screen displays blank blocks when the On key is pressed. Solution: This may be caused by low battery power. Replace the . If this doesn’t correct the problem, there may be a more serious problem that requires service.

Problem: The message on the portable unit’s LCD screen flickers. Solution: This indicates that your battery power is low. Install new.

Problem: During the backup test, the portable unit displays the message “Memory Error.” Solution: Repeat the backup test three times to clear the error.

Problem: The wand doesn’t scan barcodes. Solution: This may be caused by poor cable connection, damaged p in, bad interface circuit, or barcodes that are too light. First, check to see if the cable is plugged in tightly, and clean the tip of the wand. Then check the Unitech manual for pin assignments.

24

Spectrum® Portable Circulation and Inventory 4/8/2002

Page 25

Problem: The portable unit’s RS -232 port doesn’t work. Solution: This may be caused by poor cable connection, disabled barcode symbology, or a bad scanner. Check to see if the cable is plugged in tightly. If the cable is properly connected, check your barcode setup (see “Bar Code Setting” in the “SET Function” part of your Unitech manual); follow the guidelines in the Unitech manual to change any settings, if needed. If the problem persists, try replacing the wand with a wand that works.

Problem: The keypad doesn’t work properly. Solution: This may be caused by an operation error or a bad keypad. Refer to the Unitech manual for information about performing the keypad test. .

Index > > (Ready prompt), 7

1 1–INPUT, 21 1–ROP, 21 1–Time, 10, 11

2 2–Funkey, 10 2–STAT, 8, 21

3 3–Format, 10, 11, 13

4 4–Code, 10

Index PortInvCirc 1Amn Aug99 krn/jrr

5 5–Comm, 14, 15 5–Comm, 10 5–SET, 10, 11

6 6–Beep, 10 6–PURGE, 23

A automatic shut-off, 11

B backspace key, 5 barcode data checking status, 8 purging inventory, 23 uploading to the computer

25

Page 26

inventory, 22 barcodes checking for loaded, 20 entering into the portable unit, 21 setting up, 10 barwand, 4 connecting to the portable unit, 16 batteries, 4, 7 causing errors, 24 baud rate, 14, 15 BS (backspace key), 5

F field delimiter, 13 files, list of Macintosh, 19 Form #1: ROP, 8, 21 Form #2: CIRCULAT, 8 format setting up, 10, 11 Macintosh, 13 function keys setting up, 10

C cable, RS-232 connecting to the portable barcode reader, 16 CAPS key, 5 circulation program downloading to the portable unit after entering diagnostic mode, 7 after resetting the system, 9 communication setting up, 10, 14 Macintosh, 15 connecting barwand or scanner to the portable unit, 16 laser gun to the portable unit, 18 portable unit to the computer, 16 Universal CCD to the portable unit, 17 customer support, 9, 24

D date setting up on portable unit, 11 delay, 13 diagnostic mode, 7, 9 download, definition, 16 downloading circulation program to the portable unit after entering diagnostic mode, 7

E editing barcode data, 4 Enter Barcode prompt, 21 errors, 24 EXIT key, 5

26

I INPUT key, 7 inventory performing with the portable unit, 20 preparing materials for, 20 inventory data purging, 23

K keypad not working properly, 25 on the portable unit, 5

L laser gun connecting to the portable unit, 18

M Main Menu, 7 memory, 9, 22 memory error, 24 MENU key, 5

N NO key, 5

P portable barcode reader. See portable unit Portable CIRC Single User, 19

Spectrum® Portable Circulation and Inventory 4/8/2002

Page 27

Portable CIRC TCP/IP, 19 Portable Circ Writer, 19 Portable Circulation and Inventory installing, 20 Portable Inventory, 20 portable unit about, 5 connecting a barwand or scanner to, 16 connecting a laser gun to, 18 connecting a Universal CCD to, 17 connecting to the computer, 16 entering barcodes into, 21 keypad, 5 performing inventory with, 20 resetting, 9 setting up, 9 testing, 7 troubleshooting, 24 preparing materials for inventory, 20 problems, 24 PT-815 portable barcode reader, 4 purging inventory barcode data, 23 PW-800 portable barcode reader, 4

R Ready prompt (>), 7 Ready screen, 7 record delimiter, 13 resetting the portable unit, 9 ROP (Resident Operating Program) checking for barcodes already loaded, 21 entering barcodes into, 21 setting up, 11 storing barcodes on, 20, 23 ROP Echo, 12 RS-232 cable, 16 RS-232 port not working properly, 25

S scanner connecting to the portable unit, 16 SET key, 7, 10, 25 Set Menu opening, 10

Index PortInvCirc 1Amn Aug99 krn/jrr setting up barcodes, 10 communication, 10, 14 Macintosh, 15 format, 10, 11 Macintosh, 13 function keys, 10 time, 10, 11 volume, 10 setting up the portable unit, 9 SHIFT key, 5 sounds changing volume, 10 SPACE key, 5 Spectrum CIRC/CAT versions compatible with portable software, 4 Spectrum Portable Circulation and Inventory installing, 20 Spectrum Portable Inventory, 20 status check, 8, 21 system reset, 9

T testing the portable unit, 7 time setting up, 10, 11 time stamp, 13 troubleshooting, 24

U Unitech manual, 4, 7, 9, 10, 24, 25 Universal CCD connecting to the portable unit, 17 upload, definition, 16 uploading data to the computer inventory, 22

V versions Spectrum CIRC/CAT, 4 volume, changing, 10

W wand

27

Page 28

doesn’t scan barcodes, 24

Y YES key, 5

28

Spectrum® Portable Circulation and Inventory 4/8/2002