Page 40

PT630 Operation Guide

Page 40 of 41

7.1 MAIN/BACKUP BATTERY REPLACEMENT AND INSTALLATION Main Battery 1. Make sure the unit is turned off.

2. Turn over the unit. Slide tab from right to left (see illustrations in next page). 3. Slide the main battery pack from battery compartment. 4. Insert the new main battery packet:

1. 2.

Use screw driver or coin to screw it anti-clockwise Then remove battery cover

3. Take battery out of battery compartment

Lithium Back up Battery 1.

Refer to the procedure in previous paragraph, un-screw the backup battery cover and as illustration above to remove the lithium battery. 2. Insert a new battery into the holder with correct orientation.

3. Put the battery cover back. Make sure to back up your data in PDT before making the replacement the lithium back up battery.

1. 2.

Remove backup battery cover. Remove backup battery from backup battery compartment

Page 41

PT630 Operation Guide

Page 41 of 41

7.2 MAIN POWER BATTERY CHARGING WITH AC/DC ADAPTOR (Regular/Normal Charge) When the PDT shows “Main battery low” message or icon , the battery pack in PT630 needs to be recharged. Plug one end of an AC-9VDC/1A power adapter into the DC-jack of RS232 cable and the other end into a wall outlet. The battery pack will be fully recharged after 2-3 hours. The PT630 uses an internal Lithium battery to back up the RAM memory and system real time clock when the main battery stops supplying the required power. 7.3 MAIN BATTERY CHARGING WITH CRADLE Connect power adapter to PT063 and insert PDT into the chamber of PT063. The battery of PDT can be fully charged in about 2~3 hours and the status of battery charging is indicated by the LED on the front panel of PT063.(please refer to PT063 manual for detail information. )

Page 42

PT630 Operation Guide

Page 42 of 41

7.4 MAIN BATTERY STORAGE & SAFETY PRECAUTIONS Charging Considerations It is important to consider the surrounding temperature whenever you are charging the Li-ion battery pack. The process is most efficient at normal room temperature or slightly cooler. It is essential that you charge batteries within the stated range of 32°F to 113°F (0°C to 45°C). Charging batteries outside of the specified range could damage the batteries and shorten their life cycle. Effects Of Overcharging Batteries Overcharging may occur when a Li-ion rechargeable battery is charged in regular or quick charging rate after it has been fully charged, but there is no risk of overcharging while charged in trickle charging rate. If Li-ion batteries of PT630 are charged by a power adapter plugged directly to its DC jack for too long, they can sustain a temporary reduction of capacity due to overcharging. A battery left to charge for several weeks may appear to have minimal capacity. This type of failure can be remedied by temporarily depleting the battery of its power and recharging it to rejuvenate it. This condition can be prevented by avoiding overcharging for long periods of time or always using PT063 to charge the batteries of PDT. The PT063 starts the charging process in quick charging rate and switches to trickle charging rate when it detects the battery is fully charged. Storage and Safety Precautions Batteries should be stored in an open circuit condition and placed where there is no risk of accidental shorting or other damage. Although charged Li-ion batteries may be left unused for several months, their capacity may be reduced due to back up and internal resistance. If this happens they will require recharging prior to use. Li-ion batteries may be stored at temperatures between -4°F and 158°F (-20°C to 70°C), however they may be depleted more rapidly at the high end of this range.