PT630 Operation Guide

Page 31 of 41

Chapter 5. COMMUNICATION 5.1 INSTALLATION The RS-232 port of PT630 can communicate with the serial port of a host computer. There are two ways to carry out communication sessions: (1) LOCAL : Directly connect to the serial port of your computer system. (2) REMOTE : Connected by two attached modems and one telephone line.

5.1.1 LOCAL CONNECTION: In the Local connection method, the PT630 is directly connected by a null modem cable to the serial port of the host computer. This is the way to download or upload files from/to your PT630. Note that the communication parameters must be matched on your PT630 and host computer, otherwise, the communication will fail. CONNECTING THE PT630 TO A HOST COMPUTER Host Computer 9 Pins

2 RXD 3.TXD 5 GND 7.RTS 8 CTS

PT630

3 TXD 2 RXD 5 GND 8 CTS 7 RTS

When the flow control is set to CTS/RTS, the CTS (RTS) signal of one end is necessary to be linked to the corresponded RTS (CTS) on the other end.

5.1.2 REMOTE CONNECTION:

Page 32

PT630 Operation Guide

Page 32 of 41

The remote connection of PT630 is established by linking a pair of modems through the telephone line. Once your PT630 has been connected with a modem to a telephone line, you can dial from the PT630 to a remote host computer. The computer needs to be attached to a modem through the telephone line. After the line is connected, the data communication process can start between PT630 and PC/Host as if the two were linked locally. CONNECTING THE PT630 TO A external MODEM : PT630 Modem

2 RXD 3 TXD

2 RXD 3 TXD

4 DTR 5 GND

6 DSR 7 GND

6 DSR 7 RTS

20 DTR 5 CTS

8 CTS

4 RTS

Page 33

PT630 Operation Guide

Page 33 of 41

5.2 DOWNLOADING AND UPLOADING The PT630 supports the MULTI protocol and ESC commands for serial data communication. Once the PT630 and PC are physically connected, a data communication processing will be established when a program running on the PC sends the ESC command consistent with the protocol specified in the PT630. Connection Point-to-point Multi-point

Protocol supported OFF, or MULTI MULTI

Please refer to the PT630 Programming Reference Manual for detailed description of ESC commands. Before you download or upload a file from the PC to the PT630, connect your PT630 and HOST using the LOCAL method.

Page 34

PT630 Operation Guide

5.2.1

Page 34 of 41

Downloading a Jobgen Pro application from Host to PT630

This function downloads an existent JobGen Plus application from host to the PT630. On PT630: • Connect the RS-232 port of PT630 to the COM port of your PC by a null modem cable. • Press [⊙] key to power up the PT630. • Check the parameter settings of protocol and communication parameters of PT630. These settings must match the settings as defined in the configuration of JobGen Plus application program. If AutoSeek baud rate function is enable on JobGen Plus’s PTComm Manager, you don’t need to care about PT630’s baud rate setting, but Protocol setting should be set as Multi and other’s communication parameter should be “N,8,1”. On HOST: • Run JOBGEN Plus program. • Open Job file which is targeted to be run on PT630. • Press F4 key (or click Make Job icon, or select Built 5.2.2

Make Job).

Uploading JobGen Plus from PT630 to HOST

Having collected the data into the PT630, the user can upload one or more collected data files to a PC. On PT630: • Connect the RS-232 port of PT630 to the PC’s COM port PC with a null modem cable. • Press [⊙] key to power up the PT630. • Check the parameter settings of protocol and communication parameters of PT630. These settings must match the settings as defined in the configuration of JobGen Plus application program. If AutoSeek baud rate function is enable on JobGen Plus’s PTComm Manager, you don’t need to care about PT630’s baud rate setting, but Protocol setting should be set as Multi and other’s communication parameter should be “N,8,1” On HOST: • Run JOBGEN Plus program. • Press F10 key (or click PTComm Manager icon, or select Tools PTComm Manager • Double click Portable icon on right-upper windows and it will list down all of files which is stored on PT630 • Click file which will be sent back to PC and drop it into left windows on right path.

Page 35

PT630 Operation Guide

5.2.3

Page 35 of 41

Downloading a file from Host to PT630 using the Kermit Server

This function downloads a file from host to the PT630. On PT630: • Connect the RS-232 port of PT630 to the COM port of your PC by a null modem cable. • Press [⊙] key to power up the PT630. • Check the PT630 protocol and communication parameter settings. • Press and hold down [CMD] key for 2 seconds to enter User mode, then select “3.COM” in User mode to enter Kermit server mode.(see On HOST to process file download from Host side). Note : You can press [CMD] and [Alpha] to exit Kermit server and return to Ready mode On HOST: • • •

Run KERMIT.EXE program on PC. The program is in the PT630 Communication Utility Diskette First set the communication parameters to match the portable’s, then invoke download command by entering “SEND filename”. Enter [Q] to return to DOS.

Page 36

PT630 Operation Guide

5.2.4

Page 36 of 41

Uploading files from PT630 to HOST using the Kermit Server

Having collected the data into the PT630, the user can upload one or more collected data forms to your PC. On PT630: • Connect the RS-232 port of PT630 to the COM port of your PC with a null modem cable. • Press [⊙] key to power up the PT630. • Check the PT630 protocol and communication parameter settings. • Press and hold down [CMD] key for 2 seconds to enter User mode, then select “3.COM” in User mode to enter Kermit server mode. (see On HOST to process file download from Host side) On HOST: • Run KERMIT.EXE program on PC. The program is in the PT630 Communication Utility Diskette. • First, set communication parameters to match the portable’s. then invoke upload command by entering “GET filename”. • Enter [Q] to return to DOS.

Page 37

PT630 Operation Guide

Page 37 of 41

Chapter 6. Troubleshooting 1. If power-low icon indicator of main battery shown on LCD screen, Plug in the 9V adapter to charge the battery pack for 2~3 hours. 2. If can not power up PT630 after pressing [⊙] key, •

Charge the battery pack for 2~3 hours.

3. If can not power up PT630 after charging battery pack for 2~3 hours. • •

Check if the battery pack is placed and connected properly in the battery compartment, or Change the battery pack and charge it for 2~3 hours. If problem persists, call for service.

4. If PT630 does not upload data to host, • • •

Check if the PT630 communication parameters (COM port, baud rate, data bits, parity, stop bit ) matched the Host’s setting, or Check if the cable is plugged tightly, or Check if connectors (on cable) have correct pin assignment.

5. If host can not download application program to PT630, • • •

Check if the host communication parameters (COM port, baud rate, data bits, parity, stop bit ) matched the portable’s setting, or Check if the cable is plugged tightly, or Check if connectors (on cable) have correct pin assignment.

6. If scanner does not scan, • • •

Check if the type of scanner port is set correctly, or Check if symbology used is enabled, or If it still fails, call for service.

7. If keypad does not work properly, • •

Verify operation steps with user's manual, or Power off and on your PT630, then press some keys to check if an audible beep is generated for each key pressed. If not, call for service.

Page 38

PT630 Operation Guide

Page 38 of 41

8. If encounter any other abnormal symptoms,

Caution: The following process will clear all data in PT630 RAM disk memory) Reset (cold start) the PT630, press [CMD], [ ] and [⊙] simultaneously, press [3] in “Start Menu” press ENTER. See if symptoms went away. If not, call for service.

Page 39

PT630 Operation Guide

Page 39 of 41

Chapter 7. POWER SOURCES A Li-ion battery provide main power source. A Lithium battery is used to back up the system real time clock and content in the RAM memory when the main power source is not available. NOTE. When using the PT630 for the first time, the main battery must be charged for 3 hours. The PT630 checks the power level of the main battery when the portable terminal is in use; however, the backup battery is only checked during power-on-test. Both low battery conditions will be signal to the user by a warning message on the LCD. When the main battery reaches a low condition, the LCD flashes a warning Message (“Main Battery Low”) at one minute intervals while the portable terminal is on. The main battery can continue to supply power in normal operation for approximately 10~30 minute However, the level may reach the PT630 power cutoff point and automatically turn the Portable terminal off. In this situation, the lithium battery continues to back up data and application programs in RAM and the PT630 cannot be powered up until the main battery is recharged or replaced.