Page 20

PT630 Operation Guide

Page 20 of 41

REMOTE The PT630 will output data gathered from the bar code port or keypad to its RS-232 port. LOCAL The PT630 does not transmit gathered data to its RS232 port. Echo

Use the [ ] key to toggle between ON and OFF, then hit [ENT] to make the selection. The collected data will be displayed on the PT630 LCD when Echo is set to ON, otherwise data will not be displayed when it is set to OFF.

AutoLF

Use the [ ] key to toggle between ON or OFF, then hit [ENT] to make the selection. When AutoLF is set to ON, the PT630 will append a LF (10 hex) character to the input data block.

Mode

Use the [ ] key to toggle between BLOCK and CHAR, then hit [ENT] to make the selection. See section 3.2.2 for the description of Block and Character modes.

Line/Page

Use the [ ] key to toggle among LINE, PAGE and BOTH, then hit [ENT] to make the selection. The Line/Page parameter is useful only if dumb terminal operation has been specified as BLOCK mode. The Line/Page entry designates the termination character. The termination character can be set as: LINE Line termination: CR ( 0D hex) PAGE Page termination: CTRL-Z ( 1A hex) BOTH Line termination and page termination both.

3.2.3.3

Memory Configuration

This feature allows the user to allocate available RAM between the Execution Program and RAM disk area, and can only be done when there is no data stored in RAM. The RAM memory in the PT630 is divided into three sections: ♦System Variable

About 29KB of RAM memory is reserved for PT630 parameters.

♦RAM Disk Area

Area used to store programs and data files, similar to a physical disk of a PC.

♦Program Execution Area

Area where the applications and data are loaded, similar to the main memory in a PC.

To reallocate memory, go to the Supervisor Mode screen and press 3 (3.M_SIZE) to setup the Execution Program Area size, key in the new memory size then press [ENT]. You can allocate available RAM between the Execution Program and RAM Disk area. The size of RAM Disk will decrease when you increase the size of the Execution Program area, and vice versa. The second line in the EXEC MENU shows Min and Max number of kilobytes that can be allocated to the Execution Area.

Page 21

PT630 Operation Guide

<START MENU> 1.SUPERVISOR 2.WARM START 3.COLD START

3.2.3.4

SUPERVISOR MODE PASSWORD:

1.DEV 3.MEM 5.PWR 7.INI

2.TERM 4.FORM 6.PSWD 8.DIAG

Page 21 of 41

<<EXEC SETUP> 16KB – 480 KB OLD: 240 KB NEW: KB

FormCaching Application Program

FormCaching is a built-in application program that allows users to create a data entry application by specifying field prompt, field length, data type, input method and delimiter, etc. without writing a program and loading it (download or manually) to the PT630. <START MENU> 1.SUPERVISOR 2.WARM START 3.COLD START

SUPERVISOR MODE PASSWORD:

1.DEV 3.MEM 5.PWR 7.INI

2.TERM 4.FORM 6.PSWD 8.DIAG

DEFINE FIELD1 PROMPT (16 MAX) ITEM:

Enable the FormCaching application by selecting 4 (4.FORM) in the Supervisor mode menu. When FormCaching is enabled, the PT630 will first ask the user to specify data fields in four categories including field prompt, data length, and data type and device type. After defining all data fields, the user must [CMD] then [Alpha] key to end the setup of the data field.

Page 22

PT630 Operation Guide

Page 22 of 41

FormCaching Specification DATA FIELD DEFINITION: maximum field number=8 Category Range Description 1 FIELD PROMPT Max.16 characters set field prompting 2 MIN/MAX 1-48 set minimum field length DATA LENGTH and maximum field length 3 DATA TYPE 1.NUMERIC numeric data (0~9) or 2.ALPHANUM alphanumeric data (20H~FCH) 4 DEVICE TYPE 1.KEY ONLY input by keyboard only, 2.SCAN ONLY bar code scanning only or 3.BOTH both DATA RECORD DEFINITION Category Range Description 5 BETWEEN 1.APPEND SCREEN specify to clear or append screen 2.CLEAR SCREEN FIELD between two fields 6 FIELD 1. , 2. ; assign field delimiter 3.SPACE 4.TAB DELIMITER 7 RECORD 1.CR assign record delimiter 2.LF DELIMITER 3.CRLF 8 DATE STAMP 1.NONE 2.YYYYMMDD assign date stamp and specify 3.MMDD 4.MMDDYYYY the format of date stamp FIELD 5.DDMM 6.DDMMYYYY 9 TIME STAMP 1.NONE assign time stamp and specify FIELD 2.HHMM the format of time stamp 3.HHMMSS 10 FIELD DELAY 0-6 specify time delay between each record input in second

When FormCaching is enabled, a data file named FORM.DAT will be created in the PT630. FORM.DAT stores the data as entered by the user after FormCaching is invoked. The PT630 will not allow the user to redefine the data fields in FormCaching once the FORM.DAT has been created. The file FORM.DAT must be deleted in order to implement any change in the configuration of FormCaching. Running The Resident FormCaching Application Program Enable the FormCaching, the PT630 built-in application can be ran by switching the portable terminal to the User mode of operation and selecting “2.TER”, select “2.FORMCACHING”. The FormCaching application program will follow the setting (as previously defined by the user) as it displays prompts, requests input, and stores data in the FORM.DAT file. Pressing [CMD] then [Alpha] key will abort the current record inputting action. The user may use [ ] key to browse a previous input data record and press [CLR] key to clear the record and then input new values. Pressing [CMD] then [Alpha] at the beginning of the first field of record input will abort the FormCaching application and the portable terminal will go to the Ready mode. After collecting data, the FORM.DAT file can be uploaded to a Host/PC either by invoking the Kermit server in the User mode or remotely through the Windows-based, communication utility Communication Manager. PT630 FormCaching Defaults

Page 23

PT630 Operation Guide

Page 23 of 41

The PT630 enables FormCaching by default, the following settings also apply: DATA FIELD DEFINITION: field number=2 Category Setting Field #1 FIELD PROMPT ITEM: DATA LENGTH 32 DATA TYPE ALPHANUM DEVICE TYPE BOTH Field #2 FIELD PROMPT QTY: DATA LENGTH 4 DATA TYPE NUMERIC DEVICE TYPE KEY ONLY DATA RECORD DEFINITION Category Setting BETWEEN FIELD Append screen FIELD DELIMITER , RECORD FELIMITER CR DATE STAMP FIELD NONE TIME STAMP FIELD NONE FIELD DELAY 0

3.2.3.5

POWER or ON-OFF

The PT630 provides system power on/off feature. 1.)RESUME, 2.)AUTO OFF, 3.)ALARM 1.RESUME

Once 5 is selected, user can define the

When the Resume function is enabled, the PT630 will resume program execution from the last turn-off point when it is powered on again. The default setting is ON (enabled). 1. 2.

Press 1 (1.RESUME) At the STATUS SETUP Menu, use the [ ] key to select between RESUME ON (enable Recovery) and RESUME OFF (disable recovery) 3. Press [ENT] to complete the setting 2.AUTO OFF Use the [ ] key to set auto-off timeout from 1 to 9 minutes. The PT630 will turn itself off automatically after being idle for the time period specified in the AUTO OFF setting. The default setting of AUTO OFF is 5 minutes. The auto-off feature is disabled when set to 0 minutes. A smart power management system is built in PT630 hardware and software to conserve battery power. The PT630 power transition flow is as follows:

Page 24

PT630 Operation Guide program running wait on keyin/scan OR call INT 22H press [PWR] (switch on)

POWER ON press [PWR] (switch off)

ACTIVE

Page 24 of 41

SHUT DOWN key in bar code scan RS232 input Auto-off timeout

NMI POWER FAILURE

STAND BY press [PWR] (switch off)

♦Active

All system hardware is activated in Active mode. The system will enter Stand-by mode if it waits on input or call INT 22H.

♦Stand by

In the Stand-by mode, if a key is depressed, a bar code or RS-232 input occurs the PT630 will return to Active mode. Otherwise, the portable terminal will enter Shutdown mode if the PT630 has been idle for the specified timeout period as set in AUTO OFF.

♦Shut Down In Shutdown mode, the main power is cut off from the PT630 excluding its RAM and Real Time Clock. NOTE: To conserve battery power, keep the PT630 in STAND BY mode while waiting for input. 3.2.3.6 Password Definition This function is used to create a password. The password is used to prevent an unauthorized user from entering the Supervisor mode and accidentally change the PT630 configuration parameters. The Password may consist of maximum ten (10) alphanumeric characters ('A'-'Z', '0'-'9'). The Default password is “600”. At the User Mode menu: 1. Press 6 (6.PSWD) 2. Enter the new password 3. Press [ENT] to change the Password

OLD PASSWORD: 600 NEW PASSWORD: █

Page 25

PT630 Operation Guide

Page 25 of 41

3.2.3.7 Initialization The user can command the PT630 to execute a Cold Start that will clear all data stored in the RAM Disk and configure the terminal to default values.

Make sure your data has been backed up to a Host/PC before performing this function. At the Supervisor Mode menu: SELECT 7 1.DEV 3.MEM 5.PWR 7.SYS

2.TERM 4.FORM 6.PSWD 8.DIAG

Select 1 <SYSETEM INITIAL> 1. COLD START 2. 2.PROGRAMMING

!! WARMING !! PRUGE RAM DISK! Are You Sure ? 1=YES/0=NO

Select 2

<PROGRAMMING> 1.ADD PROGRAM 2.delete all 3.update bios

When 1.COLD START is selected, press [1] for YES to confirm and execute a Cold Start, purge the RAM DISK and return to the Ready Mode menu. Press [0] for NO, abort Cold Start and return to User Mode Menu When 2.PROGRAMMING is selected, there is three items can be choose. This is one of the main feature provide by the PT630. User can select one of the program to add/erase user’s program saved in the FlashROM of the PT630, or updating the PT630 system BIOS firmware. 1. ADD PROGRAM, the PT630 allows user store the application program into the FlashROM. The size of the FlashROM for the application program is 128KB. When ADD PROGRAM was selected, the PT630 will shows the available FlashROM free information on the screen. User may save multiple application programs into the FlashROM if the free space is still available. User may move the application program from the RAM disk to the FlashROM and free up RAM disk for data storage. This feature will also prevent any application program lost due to any accidental system failure or cold start. 2. DELETE PROGRAM, it allows user delete all of the application programs stored in the FlashROM. User will not allow to delete any single application program but delete all the application program store in the FlashROM. User will need to confirm the program delete twice in case of any accidental input. 3. UPDATE BIOS, the PT630 allows the user to update or change system BIOS in the field. Once the UPDATE BIOS been selected, the PT630 will search for any update BIOS file in the RAM disk performing the update. If BIOS file is not found, the PT630 will wait for the file to be downloaded from the communication port. After the upgrading is completed, the PT630 will automatically execute a COLD START. When this function has been chose, you will see the following windows and do the selection;

Page 26

PT630 Operation Guide Erase all data In RAM & FLASH ! Continue ? (YES/NO)

Select YES

< PROGRAMMING > Are you sure ? 1=YES/0=NO

Page 26 of 41

If BIOS file found

Select 1

< PROGRAMMING > Change BIOS to V.5.X 1=YES/0=NO

Select NO

<SYSTEM INITIAL> 1.COLD START 2.PROGRAMMING

Select 1

WARNING

: Before doing any system initialization, please make sure that you have already backup or upload all data files stored in the PT630 to your Host/PC.

3.2.3.8

Diagnostics

< PROGRAMMING > Please download BIOS file … If BIOS file not found

1. The PT630 has a built-in diagnostics program to test the terminal's hardware. The test routines are data destructive. Therefore, before running the diagnostic program, make sure you back up the data in the PT630.

When a H/W or S/W service has been made on the PT630, such as maintenance, repair or upgrade, it is strongly recommended to run the diagnostic program. Diagnostic menu

At the Supervisor Mode menu:

0.All 1.RAM 2.KEY 3.232 4.LCD 5.RTC 6.SCANNER 7.RAM BCAKUP 8.EXIT

1. Press 8 (8.DIAG) 2. The LCD will display the diagnostic menu as shown on the left 3. Select 0-8 to run the desired diagnostic routine

SELECT (0-8)?_

0. All

Run all diagnostic routines from 1 to 8 shown below.

1. RAM

Fixed pattern stuck at fault check (00, FF, 55, AA). Address test: write odd, even address data into corresponding memory location, and verify it.

2. KEY

The LCD shows the legend of a key as it is pressed. Press [CMD], then [1] to return to the diagnostic menu.

3. 232

Loop back the PT630 RS232 port by connecting TxD and RxD pins together. All communication parameters are set to default values except baud rate is set to 57600 bps. The status of the tests is shown on the LCD. Darken the dots of the LCD screen and cycle power to the LCD backlight to check if the LCD functions OK.

4. LCD 5. RTC

Current time/date is displayed. Verify. Press any key to return to the diagnostics menu.

Page 27

PT630 Operation Guide

Page 27 of 41

6. SCANNER

Connect a bar code scanner to test bar code input by scanning bar code labels. Press any key to return to the diagnostics menu.

7. RAM BACKUP

Follow the instruction displayed on the LCD to press the [PWR] key to turn the power off and on to verify the memory backup.

8. EXIT

Return to the Ready mode of operation.