Page 11

PT630 Operation Guide

Page 11 of 41

______________________________________________________ 3.2 PT630 Modes of Operation There are three modes of operation in the PT630: a. Ready Mode b. User Mode c. Supervisor Mode 3.2.1 Ready Mode The Ready mode is the default resident operating mode. In the Ready mode the PT630 is configured as a portable programmable device, and is capable of receiving files (Download) from or transmitting files (Upload) to a Host PC. Data files or recorded information collected from the PT630 are uploaded to the host whenever the host program is ready to receive the collected data. Some applications may also require prepared data files (e.g. database information). These data files are loaded to the PT630 in the same manner as application programs are downloaded. The PT630 carries out upload and download operations through its built-in RS232 port. The operator can later select one of the executable applications to run in the portable terminal via the keypad or host command sequence. After the Warm Start, the PT630 enters the Ready mode and shows the Ready mode screen as shown left. The first line indicates the model code and BIOS firmware version number. The second line shows the size of the installed RAM. The third line shows the prompt, ">" which indicates that the terminal passed the Power-on-test and is in the Ready mode of operation. Ready Mode User mode menu PT630 V1.50 MEM 512 KB

Press and Hold down [cmd] Key for two second Press [CMD] then [Alpha]

3.2.2

1.RUN 3.COM 5.ERA 7.CPY

2.TER 4.DIR 6.TYP 8.SET

User Mode

The User Mode allows the operator to issue commands to the PT630. Pressing and holding down the [CMD] key for two seconds while in the Ready Mode will invoke the User Mode (see figure below). There are eight commands: 1.RUN, 2.TER, 3 COM, 4.DIR, 5. ERA, 6.TYP, 7.CPY, and 8.SET. Select the corresponding number, 1-8, or press [ ] and [ ] to move cursor then press [ENT] to select and issue the desired command to the PT630. Pressing [CMD] then [Alpha] key will return the system to the Ready Mode.

Page 12

PT630 Operation Guide

Page 12 of 41

______________________________________________________ User Mode Commands: Command RUN TER COM DIR ERA TYP CPY SET

3.2.2.1

Usage Runs the selected executable program Terminal emulation mode or Form Caching operation Kermit server mode Display RAM disk file directory Delete a file from RAM disk Dump the content of a file to the LCD Copy data from a device/file to another device/file Set real time clock, scanner type and power-on logo

RUN

< RUN PROGRAM >

Filename: NULL

3.2.2.2

After a program is downloaded to the hand held unit, the user may invoke the RUN command and press [→] key to display the executable files stored in memory, then press [ENT] to run the program. Pressing [CMD] then [Alpha] and then pressing any key will return the PT630 to the User Mode menu.

TER

The TER command puts the PT630 in either Terminal Emulation operation or FormCaching operation. User will need to choose when the TER was selected and the PT630 execute the operation. Terminal Emulation Operation. When EXEC transfers control to this EPROM-resident application program, the PT630 operates as a dumb ASCII terminal while exchanging data with a Host computer. Data input from scanning bar code labels or key-press will be sent to the portable terminal RS-232 port. In order to carry out a successful file transfer, communication parameter setting such as baud rate, data bits, parity, stop bits and flow control, must match the setting at the Host end. Data received from the serial port is displayed on the LCD screen. The functionality of the PT630 in terminal mode depends on the format configured in the Terminal Control Table. The PT630 is either configured as free format processing or forms based processing. The PT630 examines the "data buffer" and determines if host data transfer is required. If a terminating condition exists by the reception of a terminating character, the PT630 outputs the buffer to its RS232 port. Data transfer between the host machine and the PT630 is primarily controlled by the terminating conditions specified in the Terminal Control Table. In the terminal application, the program further distinguishes the character mode communication from block mode communication. Character mode communication dictates that the PT630 sends every key (one at a time) to the host. Normally character mode communication uses None protocol, otherwise there will be an overwhelming protocol overhead. The input character may come from the keypad or barcode scanner, whichever comes first. Data characters sent over from the host system

Page 13

PT630 Operation Guide

Page 13 of 41

______________________________________________________ will always be displayed on the LCD screen. Host control commands, which have a special command header (ESC), will not be displayed on the LCD. The host commands are interpreted by the PT630 as they are received. Block mode applications perform similar functions to character mode, except that the input characters will not be sent to the host one character at a time. Instead the PT630 holds the data in its internal buffer until a termination character is received. Specifying parameter linepage, lineterm, and pageterm in the terminal control table programs the termination character. The PT630 allows at most two termination characters. FormCaching Operation. When EXEC transfers control to this EPROM-resident application program, it allows the user to create a data entry application program by simply specifying field prompt, type, length, input method and delimiter, etc. without having to write a comprehensive application program. FormCaching is enabled or disabled while the PT630 is in the Supervisor mode of operation. 3.2.2.3

COM

The COM command activates the PT630 Kermit server. Pressing [CMD] then [Alpha] returns the PT630 to the User Mode of operation. The following list shows the available Kermit commands in the Host/PC: Command

Description

SEND program

Sends a file from the Host/PC to the PT630 and stores it in the PT630's RAM disk.

GET data

Gets a collected data file from the PT630 to the Host/PC disk.

REMOTE DIR

Lists PT630 RAM disk file directory.

REMOTE DEL filename

Deletes a program or data file from the PT630 RAM disk.

BYE

Exit Kermit Mode

Before making use of the Kermit server, switch the PT630 to the Supervisor mode and set the PT630 communication parameters to match the host/PC system. See Section 3.2.3.1 Device Configuration.

Page 14

PT630 Operation Guide

Page 14 of 41

______________________________________________________ 3.2.2.4

DIR The DIR command shows RAM disk file directory with the following information: The list of file names stored in the RAM DISK. The amount of memory assigned to executable programs (Execution Area). The amount of free RAM DISK space left. (FREE DISK)

MYPRG.EXE ITEM.DAT <<END>> 2 File(s)

Press [ENT] to exit this screen and return to the User Mode menu.

3.2.2.5

ERA The ERA command allows the user to delete file by pressing [ ] or [ ] key to select an existence file then pressing [ENT]. When the selected file has been deleted, it can not be recovered. Press [CMD] then [Alpha] key to abort the ERA command and return to User Mode Menu.

< ERASE FILE > Filename: █

3.2.2.6

TYP

The TYP command dumps the contents of a file to the PT630's LCD. If the user tries to display a program or binary file, only unintelligible characters will be seen. When selecting the TYP command, the PT630 allows the user using [ ] or [ ] key to select an existence file then pressing [ENT]. The screen will display 160 (20 character x 8 line) characters at a time. Press any key to show the next page or press [CMD] then [Alpha], to warm start the PT630 and return to the Ready Mode. < TYPE FILE > Filename: █

3.2.2.7

CPY

The CPY command allows the user to make a copy of data from a source and transfer the information to destination. The source and destination can be a file or devices, such as COM, serial port or CON. The CON specifies LCD for destination and keyboard for source. Valid Source/ Destination Combination

Source file1 file1 file1 COM CON

Destination file2 COM CON file2 file2

Function copy file1 to file2 output content of file1 to serial port output content of file1 to LCD input data from serial port and store in file2 input data from keyboard and store in file2, pressing [CMD] then [Alpha] to end the data input

Page 15

PT630 Operation Guide

Page 15 of 41

______________________________________________________ 3.2.2.8

SET

<SYSTEM SETUP> 1.DATE & TIME 2.SCANNER 3.DISPLAY 4.KEYPAD 5.EXIT

3.2.2.8.1

The SET command allows the user to set system date-time, select type of bar code scanner, assign laser module scanning method, enable double verification and specify whether to show power-on logo. Select the corresponding number, 1-4, to invoke a function. Pressing the [CMD] and then the [Alpha] key returns the portable terminal to the User Mode menu.

DATE & TIME Set System Clock/Calendar

By selecting “1.DATE & TIME” in the SET menu, you can set the PT630 date and time. The date and time can be used as the time stamp to be appended to an input data record DATE-TIME SETUP by an application program. The second line shows the current system date in 1998/01/01 the format YYYY/MM/DD (year/month/day). For instance, 1998/01/01 08:00:00 indicates that date is January 1, 1996. If you want to reset the system date to August 31, 1997, then enter [1],[9],[9],[7],[0],[8],[3],[1]. Or press the [ENT] key to skip the system date setting. The third line shows the current time. The setting method is similar to setting the date. The time is expressed in the 24-hour system in the format HH:MM:SS (hours:minutes:seconds). 3.2.2.8.2

SCANNER

SCANNER

The bar code input interface of the PT630 is compatible to all major bar code scanners that are available in the market including wand, CCD and laser diode scanners. Use the [ ] key to toggle among ENABLE and DISABLE, then press [ENT].

LASER TRIG MODE : User can select whether pen is activate to read barcode label by one trigger/one scan or flash scan. If it is set NORMAL, laser beam will be emitted to scan barcode and it will stop laser beam after successfully scan barcode. User need to release trigger key and then press again to scan next label. If it is set to FLASH, user just press trigger and then release it, then scanner will automatically scan barcode. When it successfully read a barcode, scanner will continuously emit laser beam to read next label. User can press trigger again to stop automatic scanning. LASER AIM When PT630 is equipped with SE1200LR engine, user can use this setting to activate aim beam before starting scanning barcode. It will be helpful for user to focus target barcode label. Use the [ ] key to toggle among ENABLE and DISABLE, then press [ENT]. VERIFICATION When label quality is not good, and then cause error decoding. You can enable this function to let PT630 double verification input barcode. When it is set ENABLE, PT630 read barcode label twice to compare if it read the same data.

Page 16

PT630 Operation Guide

Page 16 of 41

______________________________________________________ 3.2.2.8.3 DISPLAY Enable/Disable whether to show the Power-on LOGO. Power-on LOGO enabled is the default setting. 3.2.2.8.4 KEYPAD: Setup up-case and low-case Alpha character input User can define upper-case or lower-case input on Alpha mode.

Page 17

PT630 Operation Guide

3.2.3

Page 17 of 41

Supervisor Mode

The PT630 Supervisor mode allows the user to configure and validate the PT630 hardware. To switch the PT630 to the Supervisor mode of operation do the following: 1. Turn off the PT630. 2. Press and hold down the [CMD] and [ ] keys simultaneously, then switch on the PT630 by pressing the [⊙] key. The PT630 LCD first shows the ‘START MENU” where the user has three (3) choices: 1.Enter the Supervisor mode, 2.Command the PT630 to execute a Warm Start, 3. Command the PT630 to execute a Cold Start. After selecting 1, a password entry is requested from the user to prevent unauthorized users from accidentally changing configuration parameters. The system will return to the Ready mode after 5 unsuccessful tries. The default password is “630”. The Supervisor mode menu will be shown on LCD after the correct password is keyed-in.

The Supervisor Mode function lets the user set the following functions: 1. DEV:Device Configuration 2. TERM: Terminal Configuration 3. MEM: Memory Configuration 4. FORM: FormCaching Define 5. PWR: Set Resume/Auto-Off/Alarm of program 6. PSWD: Password Change 7. SYS: System Initialization, update BIOS 8. DIAG: System Diagnostic

<START MENU> 1.SUPERVISOR 2.WARM START 3.COLD START

3.2.3.1

SUPERVISOR MODE PASSWORD:

1.DEV 3.MEM 5.PWR 7.INI

2.TERM 4.FORM 6.PSWD 8.DIAG

Device Configuration

<DEVICE CONFIG> 1.KEYPAD 2.SERIAL 3.BARCODE

When selecting the option "1.DEVICE", the LCD will offer the user 3 choices: 1) Set the keypad input Language setting, 2) Set the serial port communication parameters, and 3) Enable/disable supported bar code symbologies.

1.KEYPAD

The PT630 supports several international language setting. The default language setting is ENGLISH. Press [ ] or [ ] to select different language setting. There are Sweden/Finland, Danish, Spanish, Franch, German, and Italian. Press [ENT] to confirm the setting and return to the previous manu.

2.SERIAL

The PT630 supports one RS232 port on flat 12 pin connector. Data can be downloaded to and uploaded from the PT630 via the serial data communication

Page 18

PT630 Operation Guide

Page 18 of 41 port. The communication parameters must be set correctly in order to send/receive data via the RS232 port. Default setting for the serial port is 19200 bps,8 data bits, No parity, One stop bit The settings for the communication parameters include: Category ♦ Baud Rate ♦ Length ♦ Parity ♦ Stop bits ♦ Flow Control ♦ Protocol ♦ Address

Selection 150, 300, 600, 1200, 2400, 4800 9600, 19200, 38400, 57600. 7, 8 Even, Odd, None 1, 2 Xon/Xoff, CTS/RTS, None MULTI, OFF (None) A~Y, 0~6

PT630 Default 19200 8 None 1 None MULTI A

Press [ ] to select the setting, [ENT] to confirm the setting.

3.BARCODE when selecting Option 3. BARCODE in the Supervisor Mode, Device Configuration menu, the LCD will display the BARCODE Setup as shown below. << BARCODE SETUP>> CODE 39 ON

Press [ ] or [ ] to toggle between settings. Press [ENT] to set. Setup decoding of PT630 supported bar code symbologies Symbology Code 39

Setup Category (default) Enable/disable decoding (ON) Enable/disable full ASCII (OFF) Send/No-send Start/stop Character (NO SEND) Enable/disable Check Digit Verification (OFF)

I 2 of 5

Enable/disable decoding (ON) Enable/disable Check Digit Verification (OFF)

Codabar

Enable/disable decoding (ON) Send/No-send Start/stop Character (SEND) Enable/disable Check Digit Verification (OFF)

UPC-A

Enable/disable decoding (ON) Send/No-send Leading Digit (SEND) Send/No-send Check Digit (SEND)

UPC-E

Enable/disable decoding (ON)

Page 19

PT630 Operation Guide

Page 19 of 41

Send/No-send Leading Digit (SEND) Send/No-send Check Digit (SEND) Enable/disable Zero-Expansion (OFF) EAN-13

Enable/disable decoding (ON) Send/No-send Leading Digit (SEND) Send/No-send Check Digit (SEND)

EAN-8

Enable/disable decoding (ON) Send/No-send Check Digit (SEND)

EAN/UPC ADD-ON Disable/Optional/Required (DISABLE) Send/No-send Check Digit (SEND)

3.2.3.2

Code 128

Enable/disable decoding (ON)

EAN 128

Enable/disable decoding (ON)

Code 93

Enable/disable decoding (ON)

Code 32

Enable/disable decoding (ON)

User code 1

Enable/disable decoding (OFF)

User code 2

Enable/disable decoding (OFF)

ASCII Terminal Configuration

The TERM command enables the PT630 to run a built-in Terminal emulator. The PT630 will operate as a dumb ASCII terminal when the user select this feature and disable the FormCaching menu.

<START MENU> 1.SUPERVISOR 2.WARM START 3.COLD START

SUPERVISOR MODE PASSWORD:

1.DEV 3.MEM 5.PWR 7.INI

2.TERM 4.FORM 6.PSWD 8.DIAG

<TERM SETUP> TERM I.D. PT630

When the TERM SETUP menu (shown below) appears on the PT630 LCD, proceed to set up the portable terminal communication parameters. When finished go to the User Mode menu and press 2 (2.TERM) to make the PT630 operate as a dumb ASCII terminal. Terminal ID Each PT630 "Terminal" can be identified by an 8-character string Terminal ID assigned by the user. Initially, the default ID is "PT630". Valid characters for assigning Terminal ID are alphanumeric characters ('A'-'Z', '0'-'9'). Hit [ENT] to make the selection. Online

Use the [ ] key to toggle between REMOTE and LOCAL, then hit [ENT] to make the selection.

<<TERM SETUP>> TERM ID.

PT630

<<TERM SETUP>> ONLINE REMOTE