Page 71
Unitech Electronics Co., Ltd
Created by Yukiko
PA960 Operation Manual
V2.3
Page 71 of 144
3.17 Taskman
Path: My Computer/Windows/TASKMAN.exe
This tool shows the tasks that are running currently.
1. Double tap “TASKMAN”.
2. Active tasks are shown. Select a task you want to terminate, tap “End Task”.
Page 72
Unitech Electronics Co., Ltd
Created by Yukiko
PA960 Operation Manual
V2.3
Page 72 of 144
3.18 visadm Path: My computer/Windows/visadm.exe
This tool supplies registration commands on its command line and redirect output to the file when you want to use MSMQADM.EXE on WIN CE. VISADM.EXE is a dialog box with an edit control that allows users to input MSMQADM commands as they would appear on the command line and view the output in a text box above. There is also a Shortcuts dialog box that automates several frequently used commands and allows you to view the MSMQ log file and MSMQ-specific registry entries.
1. To install MSMQ using the VISADM Utility Run VISADM.EXE.
Page 73
Unitech Electronics Co., Ltd
Created by Yukiko
PA960 Operation Manual
V2.3
Page 73 of 144
1.
From the Shortcuts menu, choose Install.
2.
From the Shortcuts menu, choose Register to create the registry entries.
3.
Reboot the computer.
4.
Test your installation.
Other Commands Available from the Visadm Shortcuts Menu •
The Stop command stops the MSMQ driver after it has been installed.
•
The Start command restarts the MSMQ driver.
Page 74
Unitech Electronics Co., Ltd
Created by Yukiko
PA960 Operation Manual
V2.3
Page 74 of 144
•
The Log command displays the contents of the MSMQ log file.
•
The Verify command interprets registry settings and produces readable information about MSMQ installation.
You can customize your installation options by using direct MSMQADM commands from the VISADM command prompt. Type the command in the edit box exactly as if you were supplying command-line arguments to MSMQADM and press the Enter key to execute. The output appears in the read-only dialog box that is displayed above the edit box.
3.19 wceload Path: My computer/Windows/wceload.exe This tool is exist to execute *.cab file.
3.20 WMAGS46 Path: My Comnputer/Windows/WMAGS46.exe
This is the driver of Lucent Orinoco Wireless LAN card. It allows you to make the setting for the wireless connection. 1. Insert Lucent Orinoco Wireless LAN card into the terminal. 2. Select “Obtain IP address via DHCP”. 3. An icon (Lucent driver) appear on the task bar. Tap the icon.
Page 75
Unitech Electronics Co., Ltd
Created by Yukiko
4. Double tap “Edit Wireless Profile”.
5. Tap “Add”.
PA960 Operation Manual
V2.3
Page 75 of 144
Page 76
Unitech Electronics Co., Ltd
Created by Yukiko
PA960 Operation Manual
6. Under “Profile Name”, enter a name. (Ex:mytest) 7. For network type, select “Access Point”. 8. Tap “Next”.
9. Specify network name. Tap “Next”.
V2.3
Page 76 of 144
Page 77
Unitech Electronics Co., Ltd
Created by Yukiko
PA960 Operation Manual
V2.3
10. Tick “Enable Data Security”. Enter WEP key. Tap “Next”.
11. Determine to enable card power on or off. Tap “Finish”.
Page 77 of 144
Page 78
Unitech Electronics Co., Ltd
Created by Yukiko
PA960 Operation Manual
12. Tap “OK”. Lucent Card is ready for wireless connection.
V2.3
Page 78 of 144
Page 79
Unitech Electronics Co., Ltd
Created by Yukiko
PA960 Operation Manual
V2.3
Page 79 of 144
13. Tap “Tool” > “Version Info”, the information of the utility and driver is shown.
14. Select/deselect “Load/unload automatically”. 15. Select/Deselect “Suspend While Connected”. If select “Suspend While Connected”, the terminal will be suspend according to the time set in suspend mode even if the RF connection is on. If deselect “Suspend While Connected”, the terminal will not be suspend while the RF connection is on.
Page 80
Unitech Electronics Co., Ltd
Created by Yukiko
PA960 Operation Manual
V2.3
Page 80 of 144
16. Select “Disable Radio” to disconnect RF connection. (select “Enable Radio” to connect the RF) 17. Select “Advanced” > “Link Test”, users can check the link of RF.
18. Select “Advanced” > “Site Monitor”, tap “Open”, the user can check signal strength.
19. Tap “Advanced” > “Network Troubleshooting”. You may check your current IP.