The text of a manual · part 3 of 15
PA960 Operation Manual, pages 21 to 30
Pages 21 to 30 of 144
The original document is the PDF (10 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Unitech PA960
Page 21
Unitech Electronics Co., Ltd
Created by Yukiko
PA960 Operation Manual
V2.3
(Example: Ping to my computer) 4. Specify the timeout time. 5. Tick “Constant Ping”. 6. Select interval time. (Example: 1 seconds). Tap OK.
7. Terminal start to ping (to my computer) in every second.
8. Under “Tools” menu, select “Local IP”. 9. Local IP window pops up and shows the IP address of this terminal.
Page 21 of 144
Page 22
Unitech Electronics Co., Ltd
Created by Yukiko
PA960 Operation Manual
V2.3
Page 22 of 144
10. Select “Exit” under “Tools” menu to close Uniping.
2.10 Scanner Settings
Path: Control Panel/Scanner Settings.exe This tool allows you to make some settings on scanner such as barcode symbologies, barcode IDs, data options, data editing, scanning options in order to change the scanner behaviour. Besides, it allows a scanning test. Every time change the setting, must click “Apply” button to get the effect. 1. Double tap “Scanner Settings”.
2. Under “Setting” tab, tap “Barcode Symbologies”.
Page 23
Unitech Electronics Co., Ltd
Created by Yukiko
PA960 Operation Manual
V2.3
Page 23 of 144
3. Tap “+” in front of “Barcode Symbologies”. You will see a list of available barcode type.
4. Tap “+” to expand the tree. Under each barcode type, there are more options such as enable/disable, check digit verification, transmit check digit etc. Tick the options that you want to apply on that barcode. Then, tap “Apply” button.
Page 24
Unitech Electronics Co., Ltd
Created by Yukiko
PA960 Operation Manual
V2.3
Page 24 of 144
5. The scanner decoder will work as what you have specified. 6. Tap “Barcode IDs”. A list of barcode type is shown with their IDs in front.
7. Double tap the barcode type which you want to change ID. (Example: D: EAN13). Change to other ID by scrolling the button.
Page 25
Unitech Electronics Co., Ltd
Created by Yukiko
PA960 Operation Manual
V2.3
Page 25 of 144
8. Tap “Data Options”.
9. Tap “Transmit code ID character” if you want to transmit code ID. 10.Double tap “Preamble” or “Postamble” if you want to add them to the barcode. Key in the special character stated in the Set Data window. Tap “OK”.
Page 26
Unitech Electronics Co., Ltd
Created by Yukiko
PA960 Operation Manual
V2.3
Page 26 of 144
11. Double tap “Interblock delay”. Select the delay time from the drop down list.
12. Tap “Data Editing”. Tap “Add” at the bottom. A menu will pop up.
Page 27
Unitech Electronics Co., Ltd
Created by Yukiko
PA960 Operation Manual
V2.3
Page 27 of 144
13. Select “Add Formula” or “Add Formula: Output All Data”. A formula will be added under “Data editing”.
14. Tap “Formula 2”. Tap “Add” button. Select “Add Qualifier”.
Page 28
Unitech Electronics Co., Ltd
Created by Yukiko
PA960 Operation Manual
V2.3
Page 28 of 144
15. Tap the qualifier you just added. Tap “Add” button. Select “Add modifier”.
16. To delete a formula or qualifier or modifier, just tap it and tap “Del” button.
Page 29
Unitech Electronics Co., Ltd
Created by Yukiko
PA960 Operation Manual
V2.3
Page 29 of 144
17. To add additional formula , just tap “Data Editing”, tap “Add” and select “Add Formula”. 18. Double tap “Magnetic Reading Options”. (The effect will only work for PA960-MSR model).
19. Double tap the options below “Magnetic Reading Options” to make settings.
Page 30
Unitech Electronics Co., Ltd
Created by Yukiko
PA960 Operation Manual
V2.3
Page 30 of 144
20. Tap “Scanning Options”. Double tap options below to make setting.
21. Under “Test” tab, tap “A-Scan” button at the bottom.