Page 42
Chapter 5 Managing Programs
Accessing Programs Your PA500 supports a variety of PDA and wireless communication programs to help you manage both personal and work-related information.
To open a Program:
36
•
Tap a program name from the Start menu.
•
Tap Start → Programs, then tap a program icon. You can select which programs are displayed on the Start menu. For instructions, see “Adding a Program to the Start Menu” on page 47.
Page 43
Chapter 5 Managing Programs
Using the Barcode Scanner Programs Scan2Key The Scan2Key application routes input from a scanner port to a keypad buffer. Using Scan2Key, scanned data can be directly input into scanner port aware application, like Word Mobile.
To open Scan2Key: 1.
Tap Start → Programs.
2.
Tap Scan2Key. Scan2Key appears as an icon on lower right corner of the Today screen.
37
Page 44
To exit Scan2Key: 1.
On the Today screen, tap and hold the Scan2Key icon, then tap Exit on the pop-up menu. The Quit Scan2Key dialog box appears.
2.
Tap Yes.
Scanner Settings When it is necessary to change the default barcode symbology for a different application, the Scanner Control Panel provides the ability to change default symbology. The Scanner Control Panel also lets you place delimiter characters behind scanned data and save the settings.
To view the default barcode symbologies: 1. 2.
38
Tap Start → Settings. On the System tab, tap Scanner Settings.
Copyright 2007 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co., Ltd.
Page 45
Chapter 5 Managing Programs To view the default barcode symbologies: 1. 2. 3.
Tap Start → Settings. On the System tab, tap Scanner Settings. On the Settings tab, tap the plus sign in front of Barcode Symbologies to expand and display the list of barcode symbologies.
Below table lists the standard protocol for a particular type of barcode symbology. Symbology
Enable/ Check Transmit Transmit Transmit Other Disable Char/Digit Check Leading Leading verification Char/ Char/ Digit Digit Digit Bookland EAN YES, - - - - Codabar YES YES YES YES, CLSI format, 3 to 48 data length Code 11 YES, YES, - 2 check digits, 1 to 48 data length Code 128 YES, - - - 1 to 64 data length Code 32 YES, - - YES Transmit tailing digit (Pharmacy Code) Code 39 YES YES YES YES YES Full ASCII, Function Code, 0 to 48 data length, Double labels decoding, Double labels separator Code 93 YES, - - - 1 to 48 data length Delta Code YES YES YES, - - EAN 128 YES, - - - Transmit Code ID, Field separator EAN 13 YES, YES, YES, EAN 8 YES, YES, YES, 39
Page 46
Symbology
Interleaved 2 of 5
Label Code IV&V MSI/Plessey
40
Enable/ Check Transmit Transmit Transmit Other Disable Char/Digit Check Leading Leading verification Char/ Digit Digit Digit YES YES YES, - Fixed Length, Not suppress start or stop digit, 10 to 64 data length YES, YES, - - YES, YES, - Standard 2 of 5/Toshiba (China Postal Code) Group Telepen
YES
YES
YES, - YES, - - - UPC A UPC E
YES YES, - YES YES, - YES YES
UPC/EAN Group, - - - - Check digit double module 10, 1 to 16 data length Fixed Length, 4 to 48 data length
Standard character set Zero Expansion, NSC Supplement 2, Supplement 5, Insert Space before supplement, Must have supplement, Add-on code try level
Copyright 2007 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co., Ltd.