Page 37

Appendix D. Setup Menu D.1 Device Selection and Default:

Enter Group 1 Device ID 0

1

2

3

Group Default Device Type

.

00 – IBM PC/XT 01 – IBM PC/AT, PS/2 MOD 40, 60, 80, USB etc. 02 – IBM PS/2 MOD30(8086) 25, 56, 70, 90 08 – IBM 3196/3197 09 – IBM 3476/3477 10 – IBM 3191/3192/3270PC 11 – IBM 3486/3487/3488 13 – IBM /3471/3472(/3179) 15 – IBM 3180 17 – IBM 3151 19 – IBM 5550-5P 20 – IBM 5550-6P 06 – Keyboardless Wedge(PC/AT) 03 – Macintosh (ADB Port) 04 – Serial Wedge 35 – Serial TTL inverted 25 – Terminal Wedge 26 – Wand emulation (Native Output) 07 – Wand emulation (with Code 39 output)

4

5

6

Factory Default 7

8

Exit

9

Page D.1

Page 38

D.2 Beeps and Delays

Enter Group 2

Group Default Beep Tone:

0

1

0 -- None 1 -- Low 2 -- Medium 3 -- High 4 -- Low to High 5 -- High to Low

A1

Interblock Delay: 2

3

0 -- 0 ms 1 -- 10 ms 2 -- 50 ms 3 -- 100 ms 4 -- 500 ms 5 -- 1 seconds 6 -- 3 seconds 7 -- 5 seconds

A2

Intercharacter Delay: 4

5

6

7

0 -- 0 ms 1 -- 1 ms 2 -- 2 ms 3 -- 5 ms 4 -- 10 ms 5 -- 30 ms 6 -- 500 ms 7 -- 100 ms

A3

MPU Idle Status 0 – MPU sleep mode 1 – MPU watch mode 2 – MPU stand by mode Here1/2 selections are for power saving mode. If you select this selection, the scanner may loss some other benefits like Caps Lock Tracing function.

A4

8

9

Exit Page D.2

Page 39

D.3 Keyboard Wedge Settings

Enter Group 3

Group Default

Function Code: 0

0 -- Off 1 -- ON

B1

Caps-Lock: 1

0 – Auto Trace(PC/XT,AT) 1 – Lower Case 2 – Upper Case

B2

Language (For PC/XT/AT): 2

3

0-U.S. 1-U.K. 2-Swiss 3-Swedish 4-Spanish

5-Norwegian 6-Italian 7-German 8-French 9-Alt Key Mode

:-Danish

Output of Wand Emulation: 0 - Bar with High/Space with Low 1 - Bar with Low/Space with High

4

B4

Level Duration of Mini Width: 0 - 200us 1 - 600us

5

B3

B5

Polarity of Idle Condition: 0 - Low 1 - High

B6

Pre-define Label: 6

0 - Label 0 1 - Label 1 2 - Label 2 (See “Pre-defined label” section for detail)

B7 7

Use number keypad digits: 0 - Disable 1 - Enable B8

8

9

Exit

Page D.3

Page 40

D.4 RS232 Settings

Enter Group 4

Group Default Baud Rate:

0

0 -- 300 1 -- 600 2 -- 1200 3 – 2400

4 – 4800 5 – 9600 6 – 19200 7 – 38400

C1

Parity: 1

0 – Even 1 – Odd 2 – Mark

3 -- Space 4 -- None

C2

Data Bit: 2

0–7 1–8

C3

Handshaking (for serial wedge): 3

0 -- Ignore 1 – RTS Enable at Power up 2 – RTS Enabled in Communication

C4

ACK/NAK ( for serial wedge ): 4

0 – Off 1 – On

C5

BCC Character ( for serial wedge ): 0 – Off 1 – On

5

6

C6

Time Out( for serial wedge): 0 -- 1 sec 1 – 3 sec 2 – 10sec 3 – Unlimited

C7

Data direction(for Terminal Wedge): 7

0 – Send to Host 1 – Send to Host and Terminal 2 – Send to Terminal

C8

8

Exit

9

Page D.4

Page 41

D.5 Scanner Port:

Enter Group 5

0

Group Default Terminator: 0 - Enter 1 - Return (on digits keypad) 2, Field Exit or Right Ctrl 3 - None Code ID: 0 – disable 1 – Enable Note: This setting doesn’t affect EAN128 Code ID. EAN128 has its own Code ID setting on page D.7.

1

2

3

4

D1

D2

Define Code ID: 00–Code 39 Full ASCII 11–MSI Code 12– EAN128 01–Code 39 Standard 13–Code32 (Italian 02–EAN-13 harmacy) 03–UPC-A 14–Delta Code 04–EAN-8 15–Label Code 05–UPC-E 16–Plessey Code 06–Interleaved 2 of 5 17– Code 11(Special) 07–Codabar 18–China Postal code 08–Code 128 (Toshiba Code) 09–Code 93 10–Standard 2 of 5

D3 Scan two digits to choose a code, then scan a char. From full ASCII table to define ID.

Double Verification: 0 – Off 1~7 – On(Verify 1~7 times)

D4

Scanning Mode: 5

0 –Trigger Mode 2 –Multiscan Mode 4-–Test Mode

1– Flashing Mode 3–One Press One Scan 5–Old Laser flash Mode

D5

Label Type: 6

0 – Positive 1 – Positive and Negative

D6

Aim function for long range laser engine: 7

8

9

0 - Disable 1 - Enable Preamble

PP

D7

Postamble

OO Scan ‘PP\OO’ for Pre\Postamble. Scan characters from Full ASCII char or Function

Page D.5

Exit

Page 42

D.6 Magnetic Reader

Enter Group 6

Group Default Terminator

0

0 - Enter 1 - Return (on digits keypad) 2, Field Exit or Right Ctrl 3 - None

E1

Start/Stop Sentinel 1

2

3

4

5

6

7

0 - No Send 1 - Send

E2

Track Selection 0 - All Tracks 2 - Track1 & track3 4 - Track 1 6 - Track 3

1 - Track1 & track2 3 - Track2 & track3 5 - Track 2

Track 2 Account Number Only 0 - No 1 - Yes Separator Character Scan a character from Full ASCII table. Default: None Output Data even other selected tracks may have some errors. 0 - No 1 - Yes Track I Output Sequence: Scan characters from full ASCII Table. Maximum is 16 character. Scan right to end. Default: None. Track II Output Sequence: Scan characters from full ASCII Table. Maximum is 8 character. Scan right to end. Default: None.

E3

E4

E5

E6

PP

OO

8

Exit 9

Page D.6

Page 43

D.7 Code 39 / I 2 of 5 / S 2 of 5 / Code 32 / EAN128

Enter Group 7

Group Default Code 39:

0

1

2

3

4

0/1--Disable/Enable. 2/3--Full ASCII/ Standard. 4--Check Digit (CD) Calculate & Send. 5--CD Calculate, not send. 6 --CD not Calculate. 7/8 -- Send/No Send Start/Stop 0 - 48 -- Min length 0 / Max length 48 I 2 of 5 (ITF): 0/1--Disable/Enable 2/3--Fix Length On/Off ( by first three reads) 4--Check Digit (CD) Calculate & Send 5--CD Calculate, not send. 6--CD not Calculate 7--First Digit Suppressed. 8--Last Digit Suppressed 9 -- Not Suppressed 2 - 64 -- Min length 10 / Max length 64

F1

F2

S 2 of 5 / China Postal Code(Toshiba Code): 0/1--Disable/Enable 2/3 -- Fix Length On/Off ( by first three reads) 4--Check Digit (CD) Calculate & Send 5--CD Calculate, not send. 6--CD not Calculate 1 - 48 -- Min length 4 / Max length 48

F3

Code 32(Italian pharmacy): 5

0/1 -- Disable/Enable 2/3 -- Leading Character Send / No Send 4/5 -- Tailing Character Send / No Send

F4

Reserve F5

6

7

UCC/EAN 128: 0/1 - disable/Enable 2/3 - Code ID disable/Enable Note: If EAN128 be disabled, the EAN128 labels will be decoded as Code 128

F6

Define the EAN128 Fields separator: Scan a ASCII code in full ASCII code chart to select a new definition of Func1 Min Length

F7

8 MM 9

Max Length

NN

Page D.7

Exit

Page 44

D.8 Code 128 / MSI Code / Code 93 / Codabar/ Label Code:

Enter Group 8

Group Default

Code 128: 0

0/1 -- Disable/Enable 1-64 -- Min Length 1 / Max Length 64

G1

MSI /Pleasey Code: 1

2

0/1 -- Disable/Enable 2/3 -- Check Digit Send / No Send 4 -- Check Digit Double Module 10 5 -- Check Digit Module 11 plus 10 6 -- Check Digit Single Module 10 1-16 -- Min Length 1 / Max Length 16

Code 93: 0/1 -- Disable/Enable 1-48 -- Min Length 1 / Max Length 48

3

4

G2

G3

Code 11: (Special) 0/1 -- Disable/Enable 2/3 -- One / Two Check Digit 4/5 -- Check Send / No Send 1-48 -- Min Length 1 / Max Length 48

G4

Codabar: 5

6

0/1 -- Disable/Enable 2/3 -- Start & Stop Send / No Send 4 -- Check Digit Calculate & Send 5 -- Check Digit Calculate but not Send 6 -- Check Digit not Calculate 7/8 -- CLSI Format On / Off 3-48 -- Min Length 3 / Max Length 48

G5

Label Code IV and V: 0/1 -- Disable/Enable 2/3 – Checksum send/ No send

7

G6

Min Length 8

MM

Max Length 9

Exit NN

Page D.8

Page 45

D.9 UPC / EAN / Delta Code

Enter Group 9

Group Default

UPC-A: 0

0/1 -- Disable/Enable 2/3 -- Leading Digit Send / No Send 4/5 -- Check Digit Send / No Send

H1

UPC-E: 1

0/1 -- Disable/Enable 2/3 -- Leading Digit Send / No Send 4/5 -- Check Digit Send / No Send 6/7 -- Zero Expansion On / Off 8/9 – Disable/Enable NSC=1

H2

2

EAN-13: 3

0/1 -- Disable/Enable 2/3 -- Leading Digit Send / No Send 4/5 -- Check Digit Send / No Send 6/7 -- Bookland EAN Enable / Disable

H3

EAN-8: 4

5

6

0/1 -- Disable/Enable 2/3 -- Leading Digit Send / No Send 4/5 -- Check Digit Send / No Send

H4

Supplement Code: 0/1 -- Two Supplement Code Off / On 2/3 -- Five Supplement Code Off / On 4 -- Transmitted if Present 5 -- Must Present. 6/7 -- Srace Separator Inserted / Not Inserted

H5

Delta Distance Code: 7

0/1 -- Disable/Enable 2/3 -- Check Digit Claculated / Not Calculated 4/5 -- Check Digit Send / No Send

H6

Reserved: 8 H7

9

Exit

Page D.9