Page 9
Selecet one of the two choices for the polarity of data output:
*Level for bar (black) and low level for space (white). *High for space (white) and low level for bar (black).
Level Duration of Minmum Width :
Determine the minimum time duration for bar or space either 200 us or 600 us. Longer time means of the wand scanner.
Polarity of
Polarity of idle (without scanning) can be selected either low or high.
Page 14
Chapter 6 Setup
The scanner interface can be configured to fit the user’s specific application. Configuration parameters are stored in a non-volatile memory, which is retained even if power is lost.
6.1 Bar Code Menu Setup
The setup menu in Appendix D contains eight groups: * Group 1: Device selection.
* Group 2: Beep and delay.
* Group 3: Keyboard and Wand Emulation.
* Group 4: RS-232 Settings.
* Group 5: Scanner port.
* Group 7: Code 39,12 of 5, S 2 of 5 and Code 32.
* Group 8: Code 128, Code 93, Code 11, Codabar, and MSI.
* Group 9: UPC/EAN
* Group 10: Dump setup.
6.1.1 Setup Procedures For most parameters, proceed the following steps for the setting: 1) Locate a group that contains the parameter to be changed. 2) When you hear beep, the new setting will have been defined or updated into the memory processor. Default parameters are indicated in bold type and underlined characters. The character font is BLACK.CD = Check Digit. CDV = Check Digit Verification. Most settings require only a single bar code, but a few need several different bar codes to be scanned in order to completely define a setting. They are: Double Verification: Step1: Scan Double Verification from Group 5 Step2: Scan one digit Step3: Scan Double Verification Min Length / Max Length Stepl: Scan MIN LENGTH or MAX LENGTH Step2: Scan two digits from Appendix E. Step3: Scan MIN LENGTH or MAX LENGTH. NOTES:
1. The beep three times as a reminder that a is not yet complete. 2. If you make a mistake, forget a step, etc., scan.
Pe ee ee ee eee ees ween eee eee eee ee ee ee ee ee ees
Page 10
6.1.2 Bar Code Length Setting:
The following example illustrates how to set Code 39 with a minimum length of 5 and a maximum length of 20:
* Scan “Enter Group 7”
* Scan “F1” to select Code 39.
* Scan “MIN LENGTH” to enter minimum length setting. * Scan “0 ” and “5” to select length 5. (Appendix E)
* Scan “MIN LENGTH” to end minimum length setting.
* Scan “MAX LENGTH” to enter maximum length setting. * Scan “2” and “0” to select length 20. (Appendix E)
* Scan “MAX LENGTH” to end maximum Length Setting. * Scan “Exit” to end setup.
6.1.3 Code ID Setting:
Each bar code symbology supported by the scanner has a default ID character defined as below:
CODE ID IDENTIFIER
SYMBOLOGIES Factory SYMBOLOGIES Factory
ID ID ID MSI eO CODABAR N EAN 8 eO UPC -E E UPC -A A UK PLESSY P EAN 13 F Code 93 L FULL ASCII Code 39 M Code 11 J STANDARD Code 39 M TELEPEN J $25 Code H
INDUSTRIAL 2 OF 5 EAN 128 FF (Code 2 of 5) H China Post_Code
Code 128 K (Toshiba Code) C Code 32 (Code 39 PARAF) T INTERLEAVED 2 OF 5 I
SET ID - SETTING PROCEDURES
Setting steps:
1.Scan the SET ID bar code for a particular symbology 2.Scan one or two alphanumeric characters from the Full ASCII Table. 3.Scan the SET ID bar code again.
Page 16
Example: Define the MSI Code ID = A, Code 93 = G9 MSI:
Step1: Scan MSI Set ID (Group 8).
Step2: “A”
Step3: Scan MSI Set ID (Group 8).
Code 93:
Step1: Scan Code 93 Set ID (Group 8).
Step2: “G” from “A” Appendix E. Full ASCII Chart, Scan “9” from “A” Appendix E. Full ASCII Chart.
Step3: Scan Code 93 Set ID (Group 8).
1.The length of a Code ID is one character. If one character is set, the Code ID output will be one character. If two characters are set, the Code ID output will be two characters.
2.Only one type of Code ID will be sent.
6.1.4 Preamble (Prefix) and Postamble(Suffix):
PREAMBLE & POSTAMBLE (PREFIX AND SUFFIX)
.A012$ .A013$ PREAMBLE(16) POSTAMBLE(16) EXAMPLE:
Set PREAMBLE String as “ ##” POSTAMBLE String as “ $$ ”
SETTING PROCEDURE:
STEP 1 : Scan : PREAMBLE.
STEP 2 : Scan : “#” twice from FULL ASCII Table. STEP 3 : Scan : PREAMBLE.
STEP 4 : Scan : POSTAMBLE.
STEP 5 : Scan : “ $ ” twice From FULL ASCII Table. STEP 6 : Scan : POSTAMBLE.
FORMAT: {Preamble} {Code ID} {Bar Code} {Postamble} NOTES:
1.4 PREAMBLE is a string of up to 16 characters added to the beginning of a scanned barcode.
2.A POSTAMBLE is a string of up to 16 characters added to the end of a scanned bar code.
3.Default value for either: None.
Page 17
Page 11
6.2 Quick Setup
Appendix A has a quick setup chart, which gives you one label or one function convenience to the scanner. To setup the scanner, locate the label with the function you want and scan that label.
6.3 Batch Setup
If you need to contigure more than one scanner, you may duplicat the settings of the scanner (master) to the others. You can do this by producing a set of custom setup labels derived from the master scanner and scanning these labels configuring the other scanners.
The following label is called “Dump Settings” label. Before you scan the label, please open a text editor application (such like, Notepad, Word, etc.) Scan the following label, the settings of the scanner will dump to the screen as one or several ASCII string(s). Use any barcode printing software, select 39 symbology, and use the string(s) to generate bar code labels. You use this batch setup labels to duplicate setting to the other scanners.
.A016$
Dump Settings
EXAMPLE:
1.PROJECT ASSIGNMENTS: 1.1 Beep tone: BEEP LOW -- HIGH 1.2 Capslock Mode: CAPSLOCK ON (FIXED). 1.3 Reading Mode: CONTINUOUS AUTO OFF.
2.SETTING PROCEDURE: 2.1 Scan BEEP LOW. - -HIGH (GROUP 3) 2.2 Scan CAPSLOCK ON (FIXED). (GROUP 3) 2.3 Scan CONTINUOUS AUTO OFF. (GROUP 2).
3.All parameters will be converted to alphanumeric characters and shown on the monitor.
Page 18
: AOI7$ | : 7.0604 | iy eee
4.Print the results shown on the monitor as bar codes with a bar code printer. The bar codes should be in the Code 39 symbology.
. A017$ SA025F04
5.Scan these labels with any of the wands that must be programmed with the same settings as the first wand. Be sure to scan from the first row to the second and so on sequentially, top to bottom.
CORRECT SETTING A017 ses 5 4 .A017$ nd 4 ..--06045A02 12 5F04 | “won SFO4. 4+.(Dot) WRONG SETTING .A017$ < - - « Wrong Setting: The string “....” Consists of 4 ..0604 ca 5A02 Dots, located at the beginning of second rows. 5F04 Do not break the “....” Into multiple string. .A017$ Wrong Setting: The string lengths in the
...06045 TB \ second and third rows do not match the length EAEIIES | 7 x requirements, because rows should be in
(Dot)v lengths of four digits.
”
Wrong Setting Because you add “...
x After .A017$ 0604 4v The 0.A17$ is a FIXED parameter for setup 5A02 4v entering. It is an unchangeable parameter. 5F04. 4+(Dot)v Never adds, delete or rearrange data from the FIRST row. Page 19
Page 12
* Only the settings that are different from the default values will be dumped.
* The settings can be dumped to a PC or terminal only if that PC or terminal matches the type defined by Device Type of the scanner. The previous example of “Keyboardless Wedge” as Device Type is equivalent-to a PC/AT interface, so you cannot dump that settings to a system which dose not support a PC/AT keyboard interface.
The following label dump the settings to a PC/AT regardless what kind of device has been chosen on the scanner.
.A018$
Dump Settings On PC/AT
* You can adjust the length of the dumped strings by combining multiple strings into one or breaking one string into multiple strings. The following strings have the same effect as the dumped string listed above:
... I800C06D5 1DJ8080 80A007C005354415254.
You cannot delete any character from or add any character into the strings and the first three characters (“...””) must present in the first string.
* All characters in dumped strings are in upper case. If you see lowercase characters in dumped strings, change them to upper case.
Page 20
6.4 Scanner Configuration Manager Software
Scanner Configuration Manager is a utility program to users to configure scanner settings on a computer using the Microsoft Windows based operating system. Use this program to define the settings and then download the parameters to the scanner. Download the program from our web site at
# Scum Coubyeboe Mawes - Cau yeu Fiber uabeel emus Comfey urbe Mere 4 uh el Fiz Setting: Dew Bdsnx Took View Isp
Dar hd & & GOO & FP
AttHbute, [Data = Ai Devin
‘e+ Bie Plo spes sari Distarys.
) ® Keyboard Wedne io Rese fos Sie Aa araruer Pod
2 Darcade Symbolagies {ois Unde 4
Soi eT as
£0) 8A PS ¢ Toshilha Onde : ) Code 12 is EAN Lee i+ Hie Coule 19K
: ® MSI» Plessey Code Lis Unde us
5 fee Sl Cun kibwar
: oo) ur A i URL
{is EAN
{is i FANE fo) Code LL
{i++ & Delta Unde
Stee Mi Supq alent Gok
: | Label Code Iv and ¥
‘-- @ Data Edrong
[- a
Ready 4UUb/ 11 2 Far Udi
Page 21
Page 13
Chapter 7 Pin Assignment and Specification
7.1 Pin Assignments
.GO11$
10 1 Modular Connector (Front View) 7.1.1 Keyboard Interface
The next table shows the modular connector pinout for keyboard interface:
Pin Number Signal 1 Not Used Not Used DET GND
Terminal Data
Terminal Clock Power Input (+5V) Keyboard Clock Keyboard Data Not Used
Ol] aomlr AIT ND] nAJ;R[_ wd, Oo
Note: DET signal is bi-directional I/O pin and for internal use only.
As keyboard interface, there are two other connectors on the interface cable. The connector type and pinout differ from terminal to terminal and are not listed here.
7.1.2 RS232 Interface
The scanner supports TTL RS232 at modular connector and standard RS232 after the interface cable is attached.
Page 22
TTL RS232 Interface:
The following table shows pinout for TTL RS232 interface at modular connector:
Pin Number Signal
1 Not Used
2 Not Used
3 DET
4 GND
5 TXD
6 RTS
7 Power Input (+5V)
8 CTS
9 RXD
10 Not Used Note: (1)DET signal is bi-directional I/O pin and for internal use only.
(2)CTS and RXD are input signals and take OV to 5V only. If the scanner is used to interface with a standard RS232 port, those signals should not be connected.
Page 23
Page 14
Standard RS232 Interface:
5 1 o000 9 6 DB9 Female (Front View) Pin Number Signal 2 TXD 3 RXD 5 GND 7 CTS 8 RTS 9 VCC
7.1.3 Wand Emulation
The pinout on modular connector at the bottom of the scanner is:
Pin Number Signal 1 Not Used 2 Not Used 3 Not Used 4 GND 5 Not Used 6 Bar Code Output 7 Power Input (+5V45%) DC 8 Not Used 9 Not Used 10 Not Used
On the other end of the wand emulation cable is a squeeze released DB9 female connector. The pinout for this connector is:
Page 24
Pin Number
Signal
1
Not Used
Bar Code Output
Not Used
Not Used
Not Used
Not Used
GND
Not Used
WOloOlr IIT ND] nal; TR] w]e
Power Input
7.2 Specification * Power: -Operating Voltage: * Temperature: -Operating: - Storage: * Humidity:
+5V +5% DC.
0°C to 50°C (32°F to 122°F) -20°C to 70°C (-4°F to 158°F)
-0% to 95% relative humidity.
Page 25
Page 15
Appendix A. Quick Setup Sheet
Device Type
.C001$
PC ATIPS/2]/USB .C007$ Keyboardless .C003$
Code39 Wand Emulation .C002$ Serial Interface Scanner Mode
.F002$
Trigger
.FOO1$
Flash
.H010$
Cut Leading Digit
-HO11$
Send Check Digit .H053$
UPC-A Conversion
.F012$
None .F013$
Medium
Terminator
.DO11$
Enter
Scan Code
.C010$
U.S
.CO15$
Alt Key
Page A.1
EAN-8 .H022$
Cut Leading Digit .H024$
Cut Check Digit
.H016$
Cut Leading Digit .HO18$
Cut Check Digit -H049$
ISBN Conversion
Character Delay
.B010$ $
140us 4ms
.B013
.A009$
.A015$
Appendix A. Quick Setup Sheet
UPC-A H004$
Cut Leading Digit
.H006$
Cut Check Digit
Supplement Code+2
.H027$
Yes
.BO15$
Enable .B016$
Disable
.A007$
Display Version
.A001$
Factory Default
Page A.2
Page 16
$TA F1
$TB
F2
$TC
NIN F3 $TD IM INAUI F4 $TE MANIA F5 STF NINA F6 $TG IM NIALAT AN F7 $TH INN INUUT F8
$TI FQ
Appendix B. Function Codes Function Codes for PC
$TJ INN
F10
STK INNO
F141
$TL
F12
$TO
Cursor Right(/FC)
Cursor Left
$TQ
Cursor Up(/FE)
$TR
Cursor Down(/FF)
UN
PgUp
STT INT
PgDn
$TU
TAB
STV ITT
Back Tab
$TW INT
Esc
$TX Left Enter *$T+D*
Right Enter
$ T%K
Del
$TZ
Ins
Alt Make $T+F* Alt Break
*$T%+O*
Shift Break
*$ T%N*
Shift Make
*$T%W*
Ctrl Make $T+H*
Ctrl Break
Page B.2