Manual · Unitech
Hand Held Scanner User's Manual
Manual31 pagesPDF 11 MB
User's manual for a Unitech hand held bar code scanner: keyboard, USB, RS232, terminal and wand emulation setup and bar code menus.
Filed with · 2 models
Also filed with these models on the old site
Summary
What is in it
Unitech's user's manual for a hand held bar code scanner (a scanned copy). It explains installing the scanner as a keyboard interface with a Y cable, without a keyboard, or over USB, as an RS232 serial scanner, as a terminal interface and in wand emulation, then setting it up by scanning bar code menus (length, code ID, preamble and postamble, quick and batch setup, scanner configuration manager), with pin assignments, specifications, function codes, the setup menu and a test chart.
Its parts
- Overview
- Keyboard Interface
- RS232 Serial Interface
- Terminal Interface
- Wand Emulation
- Setup
- Pin Assignment and Specification
From the manual · read page by page
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
Scanned user manual (Version 1.0, Nov. 2006) for a Unitech hand held bar code scanner; its pages never name a model number. It explains installing the scanner as a keyboard wedge, USB, RS232 serial, terminal wedge or wand emulation device, setting it up by scanning menu labels, copying settings to other scanners, and the connector pinouts and specifications.
- What it is
- Hand held bar code scanner that works as a keyboard, RS232 serial, RS232 terminal or wand emulation scanner p. 3
- Interfaces
- Keyboard wedge (IBM PC/AT, PS/2), USB (PC or iMac), RS232 serial, serial TTL, terminal wedge, wand emulation p. 3, 4, 5, 7
- Serial settings
- 300 to 38400 bps; default 9600 baud, none parity, 8 data bit; CTS/RTS handshaking optional p. 6
- Symbologies
- Code 39 Standard and Full ASCII, UPC/EAN with supplement codes, Interleaved 2 of 5, Standard 2 of 5, MSI, Plessey, Codabar, UCC/EAN128, Code 32, Code 93, Code 128, China Postal Code (Toshiba Code) p. 3
- Power
- +5V DC operating voltage; in RS232 use, from pin 9 of the scanner connector or an adapter p. 6, 14
- Scanner connector
- 10-pin modular (RJ45) connector at the bottom of the scanner; TTL RS232 pins: 4 GND, 5 TXD, 6 RTS, 7 Power Input (+5V), 8 CTS, 9 RXD p. 4, 13
- RS232 cable end
- DB9 female: 2 TXD, 3 RXD, 5 GND, 7 CTS, 8 RTS, 9 VCC p. 14
- Temperature
- Operating 0°C to 50°C (32°F to 122°F); storage -20°C to 70°C (-4°F to 158°F) p. 14
- Humidity
- 0% to 95% relative humidity p. 14
- Light source
- 625~660nm, 0.5mW p. 31
- Wand emulation
- Device 07 outputs Code 39; device 26 outputs the native symbology p. 8, 9
- Prefix and suffix
- Preamble and postamble of up to 16 characters each; default none p. 10
- Setup
- Scanning setup menu labels; settings kept in non-volatile memory; Scanner Configuration Manager software for Windows p. 9, 12
- Manual part number
- P/N:400264, Version 1.0, Nov.1.2006 p. 31
What this manual walks you through
- Installing the scanner as a keyboard wedge with the Y cable p. 4
- Using the scanner on a PC or laptop with no keyboard attached p. 4
- Connecting the scanner by USB p. 5
- Installing the scanner on an RS232 serial port and setting baud rate, parity and handshaking p. 6, 7
- Installing the scanner as a terminal wedge and setting the data direction p. 7, 8
- Setting up wand emulation output and polarity p. 8, 9
- Setting bar code lengths, code ID characters and prefix or suffix strings p. 10
- Copying one scanner's settings to others with Dump Settings labels p. 11, 12
- Connector pinouts for keyboard, RS232 and wand emulation cables p. 13, 14
Good to know
- CTS and RXD at the modular connector take only 0 to 5 volts and should not be wired to a standard RS232 port. p. 13
- A setting of 7 data bits with no parity is treated as 7 data bits with MARK parity. p. 6
- The keyboardless feature may not work properly on some laptop computers. p. 4
- Caps-Lock Auto Trace can hurt scanning performance on some PCs; choose Lower Case or Upper Case instead. p. 5
- The label warns not to stare into the beam or view it with optical instruments. p. 31
Questions this manual answers
What are the default serial settings of the Unitech hand held scanner?
9600 baud, no parity and 8 data bits; baud rates from 300 to 38400 bps can be chosen. p. 6
How do I copy settings from one scanner to another?
Scan the Dump Settings label into a text editor, print the strings as Code 39 bar codes, and scan them in order with each other scanner. p. 11
How is the scanner powered on an RS232 port?
From the host's RS232 power line on pin 9 of the scanner connector, or else from an adapter plugged into the cable's DB connector. p. 6
What is the pinout of the scanner's DB9 RS232 connector?
DB9 female: pin 2 TXD, 3 RXD, 5 GND, 7 CTS, 8 RTS and 9 VCC. p. 14
Contents
Chapters and sections
Each line opens the PDF at its page.
- 00.pdf1
- 01.pdf2
- 02+03.pdf3
- 04+05.pdf4
- 06+07.pdf5
- 08+09.pdf6
- 10+11.pdf7
- 12+13.pdf8
- 14+15.pdf9
- 16+17.pdf10
- 18+19.pdf11
- 20+21.pdf12
- 22+23.pdf13
- 24+25.pdf14
- A1+2.pdf15
- B1+2.pdf16
- C1+2.pdf17
- C3+4.pdf18
- C5+6.pdf19
- C7+8.pdf20
- C9+10.pdf21
- C11+12.pdf22
- C13+14.pdf23
- C15+16.pdf24
- C17+18.pdf25
- C19+20.pdf26
- D1+2-改.pdf27
- D3+4-改.pdf28
- D5+6-改.pdf29
- D7+E1-改.pdf30
- F.pdf31
The whole text · 4 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file