Page 11
BCC Character: BCC check character is calculated for entire data stream by using “Exclusive OR ” method. It is sent after data stream for data verification. Time Out: You can adjust the Time Out duration for handshaking and ACK/NAK protocol to fit applications.
3.3 Serial TTL This scanner supports serial TTL interface which follows the RS232 communication data format but with TTL voltage output ranged from 0V to 5V.
Page 10
Page 12
Chapter 4 4.1
Terminal Interface
Installation To install the scanner as a terminal interface, you need a DB25 RS232 cable, a terminal wedge “Y” cable and an AC adapter. See Figure 3 for reference. Original Cable Terminal male female
"Y" Cable
SCANNER
Host AC adaptor
RS232 Cable
Figure 3. Installing as a Terminal Wedge
Installation procedures: 1) Power off the terminal and unplug the communication cable at terminal side. 2) Install the interface cable as shown in Figure 3. The “Y” cable provided in Figure 3 is for terminals with female connector on communication port. If there is a male connector on your terminal, you need a converter to change that male to female and another converter to change the female to male on host connector. 3) When the scanner is powered, a long beep sound indicates that the scanner is ready to use.
Page 11
Page 13
4) If the scanner has not been configured yet, you need to select “Terminal Wedge” device number from Appendix A, Group 1 of Appendix D, or the following label.
Terminal Wedge
4.2
Understanding the Operating Parameters Baud Rate, Parity and Data Bit: These parameters set the scanner’s communication protocol which must be matched the same setting by the host. The default setting for the terminal interface is 9600 baud rate, none parity, and 8 data bit. * Baud Rate can be 300, 600, 1200, 2400, 4800, 9600, 19200, or 38400 bps. * Parity can be even, odd, space, mark, or none. * Data Bit can be 7 or 8 bit long. The scanner may not support settings with Data Bit as 7 and Parity as none combination. Such combination is treated as 7 data bits with MARK parity. Data Direction: This setting is only for the terminal wedge and corresponds to the terminal communication mode. If the terminal has: * "Full Duplex" mode, set the data direction to "Send to Host". * "Half Duplex" mode, set to "Send to Host and Terminal". * "Block" mode, set to "Send to Terminal".
Page 12
Page 14
Chapter 5 5.1
Wand Emulation
Installation Figure 4 shows how a wand emulation scanner is installed to a data collection terminal. User needs to pay attention to the scanner pinout that should be the same as specified by the terminal.
SCANNER
Figure 4. Installed as a Wand Emulation Scanner
5.2
Understanding the Operating Parameters Code 39 Output: When device number “07” is selected, the scanner is set as wand emulation with Code 39 output. In this configuration, the scanner always outputs data with Code 39 symbology no matter what symbology of the label it scans. You may scan the following label if this setting matched your application.
Code39 Wand Emulation
Native Output: When device number “26” is selected, the scanner is set to wand emulation with native output. That means the scanner outputs data with both the same contents and symbology as the label represents.
Page 13
Page 15
Output of Wand Emulation: (Appendix D, 3) Select one of the two choices for the polarity of data output: * High level for bar (black) and low level for space (white). * High level for space (white) and low level for bar (black). Level Duration of Minimum Width: (Appendix D, 3) Determine the minimum time duration for bar or space either 200 us or 600 us. Longer time means slower movement of the wand scanner. Polarity of Idle: (Appendix D, 3) Polarity of idle (without scanning) can be selected either low or high.
Page 14
Page 16
Chapter 6
Setup
The scanner interface can be configured to fit the user's specific application. All configuration parameters are stored in a non-volatile memory, which is retained even if power is lost.
6.1
Bar Code Menu Setup The setup menu in Appendix D contains eight groups: * Group 1: Device selection. * Group 2: Beep and delay. * Group 3: Keyboard and Wand Emulation. * Group 4: RS-232 Settings * Group 5: Scanner port. * Group 7: Code 39, I 2 of 5, S 2 of 5 and Code 32. * Group 8: Code 128, Code 93, Code 11, Codabar, and MSI. * Group 9: UPC/EAN, and Delta Distance Code. * Group 10: Data Editing. * Group 11: Dump setup.
6.1.1 Setup Procedures: For most parameters, proceed the following steps for the setting: 1) Locate a group that contains the parameter to be changed. 2) Scan the "Enter Group #" label to enter setup mode. The green LED on the scanner will flash to indicate that setup is in progress. 3) Scan the label (on right hand side) representing the parameter to be changed.(For example, B1 label) 4) Scan the labels (number) representing the desired parameter value. (For example, 05, scan “0” and “5” labels.) 5) Repeat step 3 and 4, if necessary, to change the parameters in the same group. 6) Scan "Exit" label to end the group setup. The scanner will make two beeps to end the setup.
Page 15
Page 17
6.1.2 Bar Code Length Setting: The following example illustrates how to set Code 39 with a minimum length of 5 and a maximum length of 20: * Scan “Enter Group 5”. * Scan “F1” to select Code 39. * Scan “MIN LENGTH” to enter minimum length setting. * Scan “0” and “5” to select length 5. * Scan “MIN LENGTH” to end minimum length setting. * Scan “MAX LENGTH” to enter maximum length setting. * Scan “2” and “0” to select length 20. * Scan “MAX LENGTH” to end maximum length setting. * Scan “Exit” to end setup. 6.1.3 Code ID Setting: Each bar code symbology supported by the scanner has a default ID character defined as below: (If you don’t know what is the label that you’re scanning, you may use this feature to identify.) Symbology UPC-A UPC-E EAN-13 EAN-8 I 2 of 5 S 2 of 5 Code 39 Codabar Code 93 Code 128 UCC/EAN128 MSI Code 32 Delta Code Plessey Code Label Code IV,V China Postal Code
Pre-Defined A E F FF I H M N L K ]C1 O T D P B C
Page 16
Page 18
Those ID characters can be redefined through setup menu. The following example shows how to set Code 93 with ID ‘O’ and Code 128 without ID: * Scan “Enter Group 3”. * Scan “D2” to select Code ID. * Scan “1” for "Yes". * Scan “D3” to define IDs. * Scan “0” and “9” for selecting Code 93. * Scan “O” from Full ASCII Table for new ID. * Scan “0” and "8" to select Code 128. * Scan “NULL” character from Full ASCII Table for none ID. * Scan “Exit” to end setup. 6.1.4 Preamble(Prefix) and Postamble(Suffix): Preamble, the scanner adds the start of text characters before the input data. Postamble, the scanner adds end of text characters after the input data. The following is an example to set ‘STX’ as preamble and ‘ETX’ as postamble: * Scan “Enter Group 3”. * Scan “PP” to start preamble setting. * Scan ‘STX’ character from Full ASCII Table. * Scan “PP” to end preamble setting. * Scan “OO” to start postamble setting. * Scan ‘ETX’ from Full ASCII Table. * Scan “OO” to end postamble setting. * Scan “Exit”. 6.1.5 Predefined Labels The scanner provides three special labels encoded as “/FY”, “/FZ” and “/F-” in Code 39 format. The output from these labels can be defined through the setup menu. The definition of the labels share the same space with “Edit Formula definition”(See “Output Data Editing”), so you can only use either one of the function. Label 0
Label 1
Label 2
/ FY
/ FZ
/ F-
Page 17
Page 19
Here is an example how to define the output of “Label 0” as “START”, “Label 1” as “ACCEPT” and “Label 2” as “END”: * Scan “Enter Group 3” * Scan “B7” * Scan “0” to define “Label 0” * Scan “S”, “T”, “A”, “R” and “T” from Full ASCII chart * Scan “B7” to end “Label 0” * Scan “1” to define “Label 1” * Scan “A”, “C”, “C”, “E”, “P” and “T” from FULL ASCII chart * Scan “B7” to end “Label 1” * Scan “2” to define “Label 2” * Scan “E”, “N” and “D” from Full ASCII chart * Scan “B7” to end “Label 2” * Scan “Exit” to quit setup After the programming, scan “Label 0”, “Label 1” and “Label 2” listed above will have output of “START”, “ACCEPT” and “END” respectively. The characters defined in these labels can be ASCII characters or Function keys. To eliminate the definition of “Label 1”, do the following: * Scan “Enter Group 3” * Scan “B7” * Scan “1” to choose “Label 1” * Scan “B7” to end * Scan “Exit” to exit setup There is only total 24 characters space available for defining these three labels. If one of the labels has been defined the output with 24 characters, the other two labels can not be defined further.
6.2 Quick Setup Appendix A has a quick setup chart which gives you one-label-for-onefunction convenience to setup the scanner. To setup the scanner, locate the label with the function you want and scan that label.
6.3 Batch Setup If you need to configure more than one scanner, you may duplicate the settings of the scanner (master) to the others. You can do this by producing a set of custom setup labels derived from the master scanner and scanning these labels configuring the other scanners. Page 18
Page 20
The following label is called “Dump Settings” label. Before you scan the label, please open a text editor application(such like, Notepad, Word, etc..) Scan the following label, the settings of the scanner will dump to the screen as one or several ASCII string(s). Use any barcode printing software, select Code 39 symbology, and use the string(s) to generate bar code labels. You use this batch setup labels to duplicate setting to the other scanners.
Dump Settings If you have settings as the following: * Device Type is “Keybaordless Wedge”. * Do not send the check digit of UPC-A and EAN-13. * Define Preamble as “<F1>”. * Define Postamble as “<Tab>”. * Define Label 0 as “START”. When dumping settings on a PC/AT, you have the following strings: ...I800C06D51DJ8 08080A0O7C005354 415254. Print into Code 39 bar code labels:
. . . I 8 0 0 C 0 6 D5 1 DJ 8
0 8 0 8 0 A0 O7 C 0 0 5 3 5 4
415254.
By scanning the labels from top to bottom sequentially, you may duplicate the other scanners with the same settings. Page 19