The text of a manual · part 4 of 7
CCD Barcode Scanner MS250 User's Manual, pages 31 to 40
Pages 31 to 40 of 70
The original document is the PDF (2.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Unitech MS250
Page 31
Fix Length (2 Sets Available) 1. 1st Set Begin
2. Decimal Value (See Appendix A)
3. 1st Set Complete
1. 2nd Set Begin
2. Decimal Value (See Appendix A)
3. 2nd Set Complete
Minimum Length 1. Begin
2. Decimal Value (See Appendix A)
3. Complete
6.5 Interleave 25 Parameters A Check Digit Transmission <Do Not Calculate Check Digit>
Calculate Check Digit & Transmit
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
22
Page 32
Calculate Check Digit & Not Transmit
B Set Up Number of Character <Even>
Odd
C Brazilian Banking Code <Disable>
Enable
D Set 8p Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths.
<Variable>
Fix Length (2 Sets Available) 1.1st Set Beg
2. Decimal Value (See Appendix A)
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
23
Page 33
3. 1st Set Complete
1.2nd Set Begin
2. Decimal Value (See Appendix A)
3. 2nd Set Complete
Minimum Length 1. Begin
2. Decimal Value (See Appendix A)
3. CompIete
6.6 IndustriaI 25 Parameters A Reading type IATA25 Enable
<Disable>
B Check Digit Transmission <Do Not Calculate Check Digit>
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
24
Page 34
Calculate Check Digit & Transmit
Calculate Check Digit & Not Transmit
C Set Up Code Length To set the fixed length 1. Scan the “Begin“ label of the desired set. 2. Go the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. 4. Repeat the steps 1 - 3 to set additional lengths. <Variable>
Fix Length (2 Sets Available) 1. 1st Set Begin
2. Decimal Value (See Appendix A)
3. 1st Set Complete
1. 2nd Set Begin
2. Decimal Value (See Appendix A)
3. 2nd Set Complete
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
25
Page 35
Minimum Length 1. Begin
2. Decimal Value (See Appendix A)
3. Complete
6.7 Matrix 25 Parameters A Check Digit Transmission <Do Not Calculate Check Digit>
Calculate Check Digit & Transmit
Calculate Check Digit & Not Transmit
B Set Up Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. 4. Repeat the steps 1 - 3 to set additional lengths.
<Variable>
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
26
Page 36
Fix Length
(2 Sets Available)
1. 1st Set Begin
2. Decimal Value (Appendix A)
3. 1st Set Complete
1. 2nd Set Begin
2. Decimal Value (Appendix A)
3. 2nd Set Complete
Minimum Length 1. Begin
2. Decimal Value (Appendix A)
3. Complete
6.8 CODABAR/NW7 Parameters A Set Up Start/Stop Characters Upon Transmission ON
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
27
Page 37
<OFF>
B Transmission Type of Start/Stop <A/B/C/D> <Start>
<A/B/C/D> <Stop>
A Start
A Stop
B Start
B Stop
C Start
C Stop
D Start
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
28
Page 38
D Stop
C Set Up Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. Repeat the steps 1 - 3 to set additional lengths. <Variable>
Fix Length
(2 Sets Available)
1st Set Begin
Decimal Value (Appendix A)
1st Set Complete
2nd Set Begin Decimal Value (Appendix A) 2nd Set Complete
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
29
Page 39
Minimum Length Begin
Decimal Value (Appendix A)
Complete
6.9 Code 93 Parameters A Check Digit Transmission <Calculate Check 2 Digits & Not Transmit>
Do Not Calculate Check Digit
B Set Up Code Length To set the fixed length: 1. Scan the “Begin“ label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the “Complete“ label of the desired set. 4. Repeat the steps 1 - 3 to set additional lengths.
<Variable>
Fix Length
(2 Sets Available)
1st Set Begin
Decimal Value (Appendix A)
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
30
Page 40
1st Set Complete
2nd Set Begin
Decimal Value (Appendix A)
2nd Set Complete
Minimum Length Begin
Decimal Value (Appendix A)
Complete
6.10 Code 11 Parameters A Check Digit Transmission <Do Not Calculate Check Digit>
Calculate Check 1 Digit & Transmit
Calculate Check 2 Digits & Not Transmit
Copyright 2012 unitech Electronics Co., Ltd. All rights reserved. Unitech is a registered trademark of unitech Electronics Co., Ltd.
31