Page 41
D.2 Beeps and Delays
Enter Group 2
Group Default Beep Tone:
0
1
0 -- None 1 -- Low 2 -- Medium 3 -- High 4 -- Low to High 5 -- High to Low
A1
Interblock Delay: 2
3
0 -- 0 ms 1 -- 10 ms 2 -- 50 ms 3 -- 100 ms 4 -- 500 ms 5 -- 1 seconds 6 -- 3 seconds 7 -- 5 seconds
A2
Intercharacter Delay: 4
5
6
7
0 -- 0 ms 1 -- 1 ms 2 -- 2 ms 3 -- 5 ms 4 -- 10 ms 5 -- 30 ms 6 -- 500 ms 7 -- 100 ms
A3
MPU Idle Status 0 – MPU sleep mode 1 – MPU watch mode 2 – MPU stand by mode Here1/2 selections are for power saving mode. If you select this selection, the scanner may loss some other benefits like Caps Lock Tracing function.
A4
8
9
Exit Page D.2
Page 42
D.3 Keyboard Wedge Settings
Enter Group 3
Group Default
Function Code: 0
0 -- Off 1 -- ON
B1
Caps-Lock: 1
0 – Auto Trace(PC/XT,AT) 1 – Lower Case 2 – Upper Case
B2
Language (For PC/XT/AT): 2
3
0-U.S. 1-U.K. 2-Swiss 3-Swedish 4-Spanish
5-Norwegian 6-Italian 7-German 8-French 9-Alt Key Mode
:-Danish
Output of Wand Emulation: 0 - Bar with High/Space with Low 1 - Bar with Low/Space with High
4
B4
Level Duration of Mini Width: 0 - 200us 1 - 600us
5
B3
B5
Polarity of Idle Condition: 0 - Low 1 - High
B6
Pre-define Label: 6
0 - Label 0 1 - Label 1 2 - Label 2 (See “Pre-defined label” section for detail)
B7 7
Use number keypad digits: 0 - Disable 1 - Enable B8
8
9
Exit
Page D.3
Page 43
D.4 RS232 Settings
Enter Group 4
Group Default Baud Rate:
0
0 -- 300 1 -- 600 2 -- 1200 3 – 2400
4 – 4800 5 – 9600 6 – 19200 7 – 38400
C1
Parity: 1
0 – Even 1 – Odd 2 – Mark
3 -- Space 4 -- None
C2
Data Bit: 2
0–7 1–8
C3
Handshaking (for serial wedge): 3
0 -- Ignore 1 – RTS Enable at Power up 2 – RTS Enabled in Communication
C4
ACK/NAK ( for serial wedge ): 4
0 – Off 1 – On
C5
BCC Character ( for serial wedge ): 0 – Off 1 – On
5
6
C6
Time Out( for serial wedge): 0 -- 1 sec 1 – 3 sec 2 – 10sec 3 – Unlimited
C7
Data direction(for Terminal Wedge): 7
0 – Send to Host 1 – Send to Host and Terminal 2 – Send to Terminal
C8
8
Exit
9
Page D.4
Page 44
D.5 Scanner Port:
Enter Group 5
0
Group Default Terminator: 0 - Enter 1 - Return (on digits keypad) 2, Field Exit or Right Ctrl 3 - None Code ID: 0 – disable 1 – Enable Note: This setting doesn’t affect EAN128 Code ID. EAN128 has its own Code ID setting on page D.7.
1
2
3
4
D1
D2
Define Code ID: 00–Code 39 Full ASCII 11–MSI Code 12– EAN128 01–Code 39 Standard 13–Code32 (Italian 02–EAN-13 harmacy) 03–UPC-A 14–Delta Code 04–EAN-8 15–Label Code 05–UPC-E 16–Plessey Code 06–Interleaved 2 of 5 17– Code 11(Special) 07–Codabar 18–China Postal code 08–Code 128 (Toshiba Code) 09–Code 93 10–Standard 2 of 5
D3 Scan two digits to choose a code, then scan a char. From full ASCII table to define ID.
Double Verification: 0 – Off 1~7 – On(Verify 1~7 times)
D4
Scanning Mode: 5
0 –Trigger Mode 2 –Multiscan Mode 4-–Test Mode
1– Flashing Mode 3–One Press One Scan 5–Old Laser flash Mode
D5
Label Type: 6
0 – Positive 1 – Positive and Negative
D6
Aim function for long range laser engine: 7
8
9
0 - Disable 1 - Enable Preamble
PP
D7
Postamble
OO Scan ‘PP\OO’ for Pre\Postamble. Scan characters from Full ASCII char or Function
Page D.5
Exit
Page 45
D.6 Magnetic Reader
Enter Group 6
Group Default Terminator
0
0 - Enter 1 - Return (on digits keypad) 2, Field Exit or Right Ctrl 3 - None
E1
Start/Stop Sentinel 1
2
3
4
5
6
7
0 - No Send 1 - Send
E2
Track Selection 0 - All Tracks 2 - Track1 & track3 4 - Track 1 6 - Track 3
1 - Track1 & track2 3 - Track2 & track3 5 - Track 2
Track 2 Account Number Only 0 - No 1 - Yes Separator Character Scan a character from Full ASCII table. Default: None Output Data even other selected tracks may have some errors. 0 - No 1 - Yes Track I Output Sequence: Scan characters from full ASCII Table. Maximum is 16 character. Scan right to end. Default: None. Track II Output Sequence: Scan characters from full ASCII Table. Maximum is 8 character. Scan right to end. Default: None.
E3
E4
E5
E6
PP
OO
8
Exit 9
Page D.6
Page 46
D.7 Code 39 / I 2 of 5 / S 2 of 5 / Code 32 / EAN128
Enter Group 7
Group Default Code 39:
0
1
2
3
4
0/1--Disable/Enable. 2/3--Full ASCII/ Standard. 4--Check Digit (CD) Calculate & Send. 5--CD Calculate, not send. 6 --CD not Calculate. 7/8 -- Send/No Send Start/Stop 0 - 48 -- Min length 0 / Max length 48 I 2 of 5 (ITF): 0/1--Disable/Enable 2/3--Fix Length On/Off ( by first three reads) 4--Check Digit (CD) Calculate & Send 5--CD Calculate, not send. 6--CD not Calculate 7--First Digit Suppressed. 8--Last Digit Suppressed 9 -- Not Suppressed 2 - 64 -- Min length 10 / Max length 64
F1
F2
S 2 of 5 / China Postal Code(Toshiba Code): 0/1--Disable/Enable 2/3 -- Fix Length On/Off ( by first three reads) 4--Check Digit (CD) Calculate & Send 5--CD Calculate, not send. 6--CD not Calculate 1 - 48 -- Min length 4 / Max length 48
F3
Code 32(Italian pharmacy): 5
0/1 -- Disable/Enable 2/3 -- Leading Character Send / No Send 4/5 -- Tailing Character Send / No Send
F4
Reserve F5
6
7
UCC/EAN 128: 0/1 - disable/Enable 2/3 - Code ID disable/Enable Note: If EAN128 be disabled, the EAN128 labels will be decoded as Code 128
F6
Define the EAN128 Fields separator: Scan a ASCII code in full ASCII code chart to select a new definition of Func1 Min Length
F7
8 MM 9
Max Length
NN
Page D.7
Exit
Page 47
D.8 Code 128 / MSI Code / Code 93 / Codabar/ Label Code:
Enter Group 8
Group Default
Code 128: 0
0/1 -- Disable/Enable 1-64 -- Min Length 1 / Max Length 64
G1
MSI /Pleasey Code: 1
2
0/1 -- Disable/Enable 2/3 -- Check Digit Send / No Send 4 -- Check Digit Double Module 10 5 -- Check Digit Module 11 plus 10 6 -- Check Digit Single Module 10 1-16 -- Min Length 1 / Max Length 16
Code 93: 0/1 -- Disable/Enable 1-48 -- Min Length 1 / Max Length 48
3
4
G2
G3
Code 11: (Special) 0/1 -- Disable/Enable 2/3 -- One / Two Check Digit 4/5 -- Check Send / No Send 1-48 -- Min Length 1 / Max Length 48
G4
Codabar: 5
6
0/1 -- Disable/Enable 2/3 -- Start & Stop Send / No Send 4 -- Check Digit Calculate & Send 5 -- Check Digit Calculate but not Send 6 -- Check Digit not Calculate 7/8 -- CLSI Format On / Off 3-48 -- Min Length 3 / Max Length 48
G5
Label Code IV and V: 0/1 -- Disable/Enable 2/3 – Checksum send/ No send
7
G6
Min Length 8
MM
Max Length 9
Exit NN
Page D.8
Page 48
D.9 UPC / EAN / Delta Code
Enter Group 9
Group Default
UPC-A: 0
0/1 -- Disable/Enable 2/3 -- Leading Digit Send / No Send 4/5 -- Check Digit Send / No Send
H1
UPC-E: 1
0/1 -- Disable/Enable 2/3 -- Leading Digit Send / No Send 4/5 -- Check Digit Send / No Send 6/7 -- Zero Expansion On / Off 8/9 – Disable/Enable NSC=1
H2
2
EAN-13: 3
0/1 -- Disable/Enable 2/3 -- Leading Digit Send / No Send 4/5 -- Check Digit Send / No Send 6/7 -- Bookland EAN Enable / Disable
H3
EAN-8: 4
5
6
0/1 -- Disable/Enable 2/3 -- Leading Digit Send / No Send 4/5 -- Check Digit Send / No Send
H4
Supplement Code: 0/1 -- Two Supplement Code Off / On 2/3 -- Five Supplement Code Off / On 4 -- Transmitted if Present 5 -- Must Present. 6/7 -- Srace Separator Inserted / Not Inserted
H5
Delta Distance Code: 7
0/1 -- Disable/Enable 2/3 -- Check Digit Claculated / Not Calculated 4/5 -- Check Digit Send / No Send
H6
Reserved: 8 H7
9
Exit
Page D.9
Page 49
D.10 Data Editing: Enter Group 10 0
1
2
3
4
5
6
7
8
Group Default
Code Type: 0 -- Code 39 Full 12 -- EAN 128 1 -- Code 39 Std. 13 -- Code 32 2 -- EAN-13 14 -- Delta Code 3 -- UPC-A 15 – Label Code 4 -- EAN-8 16 – Plessey Code 5 -- UPC-E 17 -- Code 11(Special) 6 -- I 2 of 5 18 – China Postal Code 7 -- Codabar 19 – All Inputs 8 -- Code 128 9 -- Code 93 10 -- S 2 of 5 11 -- MSI Code Formula Format: Input ID: IN_ID, ID1, ..., IDi, Length: LEN, MIN, MAX, Match: MATCH, P1,S1, ..., Pi, Si, A-String: “abc...”, O-String: O-STR, P, N, IDi -- number for Code ID. Pi -- position. Si -- string, “abc...”. P -- number or string for start position. N -- number of char. or string to end position. Special Characters on this sheet: , -- delimiter to separate parameters. “ -- string specifier. * -- specify any digit or any position. # -- specify any letter or last position.
IN_ID
LEN
MATCH
O-STR
“
*
#
Enter
9
Backspace + -
,
Review
Page D.10
Exit
Page 50
D.11 Dump Setup Strings: See Section 6.3 for how to use the labels below.
Dump Settings
Dump Settings on PC/AT