The text of a manual · part 1 of 6
Hand Held Scanner User's Manual, pages 1 to 10
Pages 1 to 10 of 55
The original document is the PDF (211 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Unitech MS180 and Unitech MS210
Page 1
unitech
Hand Held Scanner
User’s Manual
Date : January, 2000 Version : 3.0
Page 2
CHAPTER 1 OVERVIEW ............................................................... 3 CHAPTER 2 KEYBOARD INTERFACE ....................................... 4 2.1 INSTALLATION ................................................................................... 4 2.2 INSTALLED ON PC/AT WITHOUT KEYBOARD ........................................ 5 2.3 INSTALLED ON MACINTOSH ................................................................ 5 2.4 INSTALLED AS AN USB INTERFACE .................................................... 6 2.5 UNDERSTANDING THE OPERATING PARAMETERS.................................. 6 CHAPTER 3 RS232 SERIAL INTERFACE.................................... 8 3.1 INSTALLATION ................................................................................... 8 3.2 UNDERSTANDING THE OPERATING PARAMETERS.................................. 9 3.3 SERIAL TTL ..................................................................................... 10 CHAPTER 4 TERMINAL INTERFACE ...................................... 11 4.1 INSTALLATION ................................................................................. 11 4.2 UNDERSTANDING THE OPERATING PARAMETERS................................ 12 CHAPTER 5 WAND EMULATION.............................................. 13 5.1 INSTALLATION ................................................................................. 13 5.2 UNDERSTANDING THE OPERATING PARAMETERS................................ 13 CHAPTER 6 SETUP ...................................................................... 15 6.1 BAR CODE MENU SETUP ................................................................... 15 6.1.1 Setup Procedures :.................................................................... 15 6.1.2 Bar Code Length Setting: ......................................................... 16 6.1.3 Code ID Setting:....................................................................... 16 6.1.4 Preamble and Postamble: ......................................................... 17 6.1.5 Predefined Labels..................................................................... 17 6.2 QUICK SETUP ................................................................................... 18 6.3 BATCH SETUP................................................................................... 18 CHAPTER 7 OUTPUT DATA EDITING...................................... 21 7.1. GENERAL ........................................................................................ 21 7.2. FORMULA........................................................................................ 21 7.2.1. Original Data Structure........................................................... 21 7.2.2. Formula Structure: .................................................................. 21 7.2.3. Execution Sequence ................................................................. 21 7.3. PROGRAMMING ............................................................................... 22 7.3.1. Programming Sequence:.......................................................... 22 7.3.2. Preparation ............................................................................. 22
Page 3
7.3.3. Programming Sheet ................................................................. 23 7.3.4. Parameter Entry ...................................................................... 23 7.4. QUALIFIER ...................................................................................... 24 7.4.1. Input ID................................................................................... 24 7.4.2. Length: .................................................................................... 25 7.4.3. Match ...................................................................................... 25 7.5. MODIFIER ....................................................................................... 26 7.5.1. A-String................................................................................... 26 7.5.2. O-String................................................................................... 26 7.6. EXAMPLES ...................................................................................... 27 7.6.1. Example 1................................................................................ 27 7.6.2. Example 2................................................................................ 27 7.7. ADVANCED FEATURES ..................................................................... 27 CHAPTER 8 PIN ASSIGNMENT AND SPECIFICATION ......... 29 8.1 PIN ASSIGNMENTS ............................................................................ 29 8.1.1. Keyboard Interface.................................................................. 29 8.1.2. RS232 Interface ....................................................................... 29 8.1.3. Terminal Interface ................................................................... 31 8.1.4. Wand Emulation ...................................................................... 32 8.2 SPECIFICATION ................................................................................. 33 APPENDIX A. QUICK SETUP SHEET ......................................A.1 APPENDIX B. FUNCTION CODES FOR PC..............................B.1 APPENDIX C. FUNCTION CODES FOR IBM TERMINALS...C.1 APPENDIX D. SETUP MENU ......................................................D.1 APPENDIX E. FULL ASCII CHART...........................................E.1 APPENDIX F. BAR CODE TEST CHART.................................. F.1
Page 2
Page 4
Chapter 1
Overview
First of all, thank you for choosing Unitech’s products. This decoder build-in scanner comes in one model and supports interfaces such as keyboard wedge, RS232 serial wedge, RS232 terminal wedge, wand emulation, and the latest USB interface. In most of the cases, simply selecting an appropriate cable with a device code will work for a specific interface. As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. The installation of the wedge scanner is a fairly simple process without any changes of software or hardware. As a RS232 serial interface, the scanner sends data by using RS232 communication protocol. The communication speed (baud rate) ranges from 300 bps to 38400 bps with both hardware and software handshaking are implemented. As a RS232 terminal interface, systems with ANSI ASCII communication environment such as UNIX, XENIX are supported. The scanner is installed between a host computer and a terminal and supports full duplex, half duplex and block communication modes. As a wand emulation scanner, the output of the scanner emulates a wand scanner output. Two output formats are supported, Code 39 format and Native format. In Code 39 format, the scanner always outputs the same data contents but with Code 39 symbology no matter what symbology of the label is encoded. In Native format, the scanner output the same contents and symbology as the scanned label. The scanner supports the following bar code symbologies: * Code 39 Standard and Full ASCII. * Codabar. * UPC/EAN with supplement codes. * UCC/EAN128. * Interleaved 2 of 5. * Code 32(Italian pharmacy). * Standard 2 of 5. * Code 93. * MSI code. * Code 128. * Plessey code. * Label Code IV and V * China Postal Code (Toshiba Code) * Delta Distance Code.
Page 3
Page 5
Chapter 2
Keyboard Interface
As a keyboard Interface, the scanner is actually installed between PC (or terminal) and keyboard. See Figure 1 for reference. The scanner sends data to the host device by emulating the keyboard signals input and acts like an extension of the keyboard.
2.1
Installation This scanner can be installed easily by following the installation guide illustrated below. Before you start the installation, locate a “Y” type cable in the package. Installation procedures: 1) Plug the modular (RJ45) connector of the “Y” cable into the bottom of the scanner until you hear a click sound. PC or Terminal
SCANNER Interface Cable ("Y" Cable)
Modular Connector
Keyboard
Figure 1. Installed as a Keyboard Interface
2) Turn off your PC or terminal. 3) Unplug the keyboard from the PC or terminal. 4) Plug the keyboard into a connector of the Y cable that mates with it. 5) Plug the remaining connector of the “Y” cable into the keyboard port of your PC or terminal. 6) Power up your PC or terminal you press the switch the beam should be out from the scanner. Page 4
Page 6
7) If nothing happens at step 6, check all cable connections first and make sure your PC or terminal has been powered. Contact technical support if problem remains after these checking. 8) Unless the scanner has been prior installed for the PC/terminal, user may have to select a proper device number from Group 1 of Appendix D. 9) The Default setting of this scanner is IBM PC/AT and PS/2. If you like to make sure that you have the right selection, you may scan the following label,
PC AT[PS/2]
2.2
Installed on PC/AT without keyboard or laptop computer The scanner has the capability to answer the keyboard inquiry made by PC to avoid “Keyboard Error” message when keyboard is not present. This implementation is useful to the applications where keyboard entry is not necessary. You may scan the following label to enable this feature. (Some of the laptop computers may not work properly with this feature. Please contact your local vendor for further support.)
Keyboardless
2.3
Installed on Macintosh You can install the scanner on a Macintosh ADB port similar to the way shown in Figure 1. As an option, the scanner can be installed right between keyboard and mouse too. You may scan the following label to enable this feature.
Macintosh
Page 5
Page 7
2.4
Installed as an USB Interface You can install the scanner with the USB interface cable to work with either PC or iMac USB port. See Figure 1.1 for reference. Your operating system may require the original setup CD to install the driver with initial setup. PC or iMAC
SCANNER USB Interface Cable
USB Connector
Modular Connector
Keyboard
Figure 1.1. Installed as an USB Interface
The factory default setting should work with either PC or iMac USB Interface, you may also scan the following label to make sure you get the right device setting.
USB
2.5
Understanding the Operating Parameters There are some operating parameters that can be configured to work for different applications. It will be described as follow; Intercharacter Delay Intercharacter delay is the time period that the scanner will wait before transmitting the next character after the first character was sent. If data sent by the scanner was incorrect or missing characters, a longer intercharacter delay may solve the problem. Interblock Delay Interblock delay is the minimum time interval between two adjacent scanning. If the processing speed of your host device is slower than Page 6
Page 8
your scanning speed, a longer interblock delay may ensure the data integrity. Function Code The scanner can emulate function and other special keys on the keyboard by scanning some pre-defined labels. Appendix B includes those labels for special keys on PC, Macintosh, and IBM terminals. As an option, you may also print these labels by printing their corresponding Code 39 characters (in brackets) to work with scanner. Caps-Lock This parameter tells the scanner the current Caps-Lock status of the keyboard so that the character transmitted by the scanner is in correct case. * Auto Trace (For PC AT/XT only): In Auto Trace mode, the scanner will keep track of the Caps-Lock status automatically. For some PCs, the scanning performance may be compromised because of the auto tracing. If the scanning performance is poor (or can not scan) or the scanner can not output the upper/lower case characters correctly, try to select one of the next two choices instead of auto tracing. * Lower Case: When the keyboard is in the unshifted state (CapLock is not pressed), select "Lower Case". * Upper Case: When keyboard has the CapLock key on, select "Upper Case". Alt Key Mode “ALT Key Mode” is a choice in the language selection. Sending characters by ALT key plus keys on the numeric keypad is a feature in MS-DOS. When selecting "ALT Key Mode", the scanner sends out the native ASCII combination codes to represent each character of the bar code scanned. If your system accepts ALT key sending, you can enable this mode and ignore selections of the "Upper/Lower Case" and "Language". You may find these settings on the Appendix D page D2 and D3.
Page 7
Page 9
Chapter 3 3.1
RS232 Serial Interface
Installation To use the scanner as a RS232 serial interface, a RS232 interface cable and a power adapter are required. See Chapter 8 for cable pinout and adapter specification. Figure 2 shows an installation diagram for your reference. Installation procedures: 1) Make sure the scanner’s cable has the right connector and pinout for the RS232 port of the host device. If the pinout is different from device, swapping pins is necessary to achieve proper communication. 2) If the host device has power output at RS232 interface port, the scanner can be powered by connecting that power line to pin 9 of the scanner connector. If there is no power at RS232 port, An AC adapter is needed. Plug the adapter into the DB type connector at the end of the interface cable. SCANNER Cash Register, PC or other device. AC adaptor
RS232 Connector
Figure 2. Installed as a Serial Interface
3) Plug the DB type connector of the interface cable into host’s RS232 port and power up the device. 4) When the scanner is powered, a long beep sound indicates the scanner is ready to use.
Page 8
Page 10
3.2
Understanding the Operating Parameters Device Type You will need to select the device type to “Serial Interface” from Appendix A, Group 1 of Appendix D, or the following label.
Serial Interface Baud Rate, Parity and Data Bit: These parameters set the scanner’s communication protocol that must be matched by the host. The default setting for the serial interface is 9600 baud rate, none parity, and 8 data bit. * Baud Rate can be 300, 600, 1200, 2400, 4800, 9600, 19200, or 38400 bps. * Parity can be even, odd, space, mark, or none. * Data Bit can be 7 or 8 bit long. The scanner may not support settings with Data Bit as 7 and Parity as none combination. Such combination is treated as 7 data bits with MARK parity. Handshaking: The scanner supports CTS/RTS handshaking as an option. The hardware handshaking is supported on character-by-character basis. During the communication, the scanner will stop sending data until the CTS is valid within time specified by the Time Out parameter. During this time-out waiting period: -- If CTS is valid, communication resumes. -- If CTS is not valid, the scanner sounds an error beep and discards the current buffered data.
Page 9