The text of a manual · part 4 of 4
Scanner Configuration Manager User Guide, pages 31 to 40
Pages 31 to 40 of 40
The original document is the PDF (767 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Unitech MS210
Page 31
Data Editing, continued Arrange Formulas After the formulas have been created, they must be arranged in the optimum sequence by selecting formulas and using the “Move Formula” icons (see page 3). This sequence is usually according to their qualifier - from least likely to occur to most likely to occur. In the example pictured above, a series of formulas are designed to output all the data in a bar code that follows a series of “0”s. For instance, if the actual bar code is “000045678”, the desired output would be “45678” (the original minus all the 0s occurring at the beginning of the string). If there are six 0s (Formula 1), then the output starts at the seventh position. If there are five 0s (Formula 2), then the output starts at the sixth position, etc. If, instead, we were to place the qualifier for two 0s above (before) the qualifier for six 0s, then the formula stipulating two 0s would activate even if there were six 0s in the bar code because the qualifier would stop looking for 0s after it had found two. In this case, all qualifiers with three or more 0s would be disregarded, which would not be a desirable result.
The “Everything Else” Formula If a formula is entered into the Data Editing area, then all scanned bar codes will be evaluated according to this formula. If the scanned bar code does not satisfy the requirements of the Qualifier (see page 26), then no data is output. Practically speaking, the scanner has been set up to scan only bar codes that are defined by the Qualifier. You will not be able to scan other types of bar codes. The answer to this problem is to end the sequence of formulas with a formula that has no Qualifier and whose Modifier includes all the scanned data (starts at position 1 and outputs “all remaining”). An example of this can be seen as Formula 7 above. 28
Scanner Configuration Manager
Page 32
Function Codes (Code 39) (Characters in parentheses represent Code 39 bar code printing)
F1 (%VA)
F2 (%VB)
F3 (%VC)
F4 (%VD)
F5 (%VE)
F6 (%VF)
F7 (%VG)
F8 (%VH)
F9 (%VI)
F10 (%VJ)
F11 (%VK)
F12 (%VL)
Esc (/FK)
Cursor Up (/FE)
Del (/FX)
TAB (/FI)
Cursor Down (/FF)
Left Enter (/FL)
Back Tab (/FJ)
Cursor Left (/FD)
Right Enter (/FM)
Shift Make (/FP)
Cursor Right (/FC)
PgUp (/FG)
Shift Break (/FS)
Ins (/FW)
PgDn (/FH)
Ctrl Make (/FQ)
Alt Make (/FR)
Right Ctrl (/FO)
Ctrl Break (/FT)
Alt Break (/FU)
Scanner Configuration Manager
29
Page 33
ASCII Chart (Characters in parentheses represent Code 39 bar code printing)
30
NUL (%U)
VT ($K)
SYN ($V)
SOH ($A)
FF ($L)
ETB ($W)
STX ($B)
CR ($M)
CAN ($X)
ETX ($C)
SO ($N)
EM ($Y)
EOT ($D)
SI ($O)
SUB ($Z)
ENQ ($E)
DLE ($P)
ESC (%A)
ACK ($F)
DC1 ($Q)
FS (%B)
BEL ($G)
DC2 ($R)
GS (%C)
BS ($H)
DC3 ($S)
RS (%D)
HT ($I)
DC4 ($T)
US (%E)
LF ($J)
NAK ($U)
SP Scanner Configuration Manager
Page 34
ASCII Chart, continued (Characters in parentheses represent Code 39 bar code printing)
! (/A)
, (/L)
7
” (/B)
-
8
# (/C)
.
9
$
/
: (/Z)
%
0
; (%F)
& (/F)
1
< (%G)
’ (/G)
2
= (%H)
( (/H)
3
> (%I)
) (/I)
4
? (%J)
* (/J)
5
@ (%V)
+
6
A
Scanner Configuration Manager
31
Page 35
ASCII Chart, continued (Characters in parentheses represent Code 39 bar code printing)
32
B
M
X
C
N
Y
D
O
Z
E
P
[ (%K)
F
Q
\ (%L)
G
R
] (%M)
H
S
^ (%N)
I
T
_ (%O)
J
U
‘ (%W)
K
V a (+A)
L
W b (+B) Scanner Configuration Manager
Page 36
ASCII Chart, continued (Characters in parentheses represent Code 39 bar code printing)
c (+C)
m (+M)
w (+W)
d (+D)
n (+N)
x (+X)
e (+E)
o (+O)
y (+Y)
f (+F)
p (+P)
z (+Z)
g (+G)
q (+Q)
{ (%P)
h (+H)
r (+R)
| (%Q)
i (+I)
s (+S)
} (%R)
j (+J)
t (+T)
~ (%S)
k (+K)
u (+U)
DEL (%T)
l (+L)
v (+V)
Scanner Configuration Manager
33
Page 37
TROUBLE SHOOTING Most problems that you might encounter with your scanner can be solved by using the following procedures:
• Try scanning other bar codes. If your scanner can scan other types of bar code symbologies, but cannot scan your bar codes, first check to see if your bar code is enabled. If it is, try the scanner on the same bar code type in the Bar Code Test Chart in the back of this manual. Then, insure that your bar codes are crisp and clear.
• Reset to factory default. While the SCM program is active, click the “new file” icon (see page 1) and the “download to scanner” icon (see page 1) to reset your scanner back to factory default. Please note that the factory default interface is specified as PS2/ AT/USB. If you have a different interface, then you will need to configure that also (see page 4) and then download to the scanner. Caution: this procedure will erase special configurations that you would have created.
• Test the scanner on other ports. Unitech scanners are built to the highest standards, and a perceived scanner malfunction may actually be a malfunction in the host computer. Test the scanner on the host’s other ports if possible or, if necessary, on other systems to verify that the problem is in the scanner and not in the host computer.
34
Scanner Configuration Manager
Page 38
Problems and Solutions Problem: Scanner doesn’t scan. If the scanner does not emit a light when the trigger is depressed, check the interface. Unplug the scanner and plug it back in. Try the scanner on another port if possible. Re-boot the computer. If the scanner still doesn’t scan, try the scanner on another computer to insure that the fault isn’t in the original computer. Problem: Scanner lights up but doesn’t beep. If the scanner emits a light, but doesn’t beep while scanning a bar code, try bar codes of different symbologies. If other types of bar codes scan properly, then it might be that the scanner is not configured to scan your particular symbology. If the scanner can scan other bar codes of the same symbology, then other parameters (such as minimum/maximum length, etc.) may have to be adjusted. Problem: No output from scanner. If the scanner appears to scan (emits light and beeps), but does not output data, try scanning into a word processor or Notepad session to see if it’s a software problem. If the scanner is connected by RS232 interface, make sure that the correct com port is selected. Problem: SCM cannot upload or download. SCM can currently upload and download only in the Windows operating system (NT excluded). If you have a different OS or the download function otherwise doesn’t work, prepare your scanner’s configuration in SCM in the usual manner. Then, instead of downloading, click the printer icon (see page 2) to print a series of bar codes that you can then scan into the scanner to configure it. Scanner Configuration Manager
35
Page 39
BAR CODE TEST CHART
A2 2 3 5 7 0 0 0 5 9 9 8 7 6 B
123456789-0
Codabar
Code 11
AO23399013
Code 32
WEDGE
UNITECHE Code 39 with Check Digit
Code 39
123ABC
Code 93
Unitech 128 Code 128
0123456
Delta Code
8012 3453 EAN-8
36
Scanner Configuration Manager
Page 40
BAR CODE TEST CHART
3 045214 834123 EAN-13
0987654321 Interleaved 2 of 5
(01)054123456789(01)659344 EAN 128 00270
9 789576 302398 ISBN 957-630-239-0
10017
Label Code IV
1234558
MSI Code
1122334455
Standard 2 of 5
20132000400
0
Toshiba Code
47669 13716
6
UPC-A
99
0 123457 2 UPC-E
Scanner Configuration Manager
37