The text of a manual · part 1 of 5
MS146 Bar Code Slot Reader, pages 1 to 9
Pages 1 to 9 of 41
The original document is the PDF (816 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Unitech MS146
Page 1
MS146 Bar Code Slot Reader
Rev.A unitech
Page 2
AdventureJan
Page 3
General Advisory Improper handling, storage, environmental influences and /or product modification can lead to problems during use. This is particularly true if repairs and maintenance work are not performed by trained personnel. We reserve the right to make technical modifications in accordance with technological advancements as they occur.
FCC Information This device has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the device is operated in a commercial environment. This device generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his or her own expense.
MS146 Manual
Page 4
TABLE OF CONTENTS INTRODUCTION . . . . . . . . . . . . . . . . . .
1
SCANNER CONFIGURATION MANAGER
. . . . . . . .
3
. . . . . . . . . . . . . . . . . . . .
6
Device
Beeps and Delays
. . . . . . . . . . . . . . . .
6
Keyboard Wedge
. . . . . . . . . . . . . . . .
7
. . . . . . . . . . . . . . . . . . . .
9
RS232
Scanner Port . . . . . . . . . . . . . . . . . . 11 Bar Code Symbologies Data Editing
. . . . . . . . . . . . . . 14
. . . . . . . . . . . . . . . . . . 22
SPECIFICATIONS
. . . . . . . . . . . . . . . . . 30
TROUBLESHOOTING . . . . . . . . . . . . . . . . 32 WARRANTY
. . . . . . . . . . . . . . . . . . . 35
BAR CODE TEST CHART
. . . . . . . . . . . . . . 36
MS146 Manual
Page 5
INTRODUCTION The MS146 is a family of bar code slot readers specifically designed for reading ID, membershop, or other types of cards that contain bar codes. The MS146 comes in four interfaces: PS/2, RS232, USB, and TTL Wand. The MS146 also comes in two different optical types: Visible Light (660nm) for reading normal bar codes, and Infrared Light (930nm) for reading bar codes hidden behind an opaque security film.
MS146
Normal Operation MS146A and MS146IA The Undecoded (or TTL, or Wand) MS146A requires an external decoder in order to communicate with your computer. Decoders are built into Wedge devices and many POS (Point of Sale) keyboards, such as the Unitech KP3700. The MS146A cannot be configured via Scanner Configuration Manager. Any modification of the output data must be done in the external decoder. MS146-2 and MS146I-2 The RS232 (Com Port) interface should only be used when your software is designed to accept com port input. The MS146-2 has a built-in decoder and outputs the scanned data in ASCII Code. MS146-2 input requires special software such as HyperTerminal (Bits per second: 9600, Data bits: 8, Parity: None, Stop bits: 1, Flow control: None) in order to view the output. The MS146-2 will require an optional power supply unless your computer’s com port supplies power (unlikely).
MS146 Manual
1
Page 6
MS146-3 and MS146I-3 The MS146-3 AT keyboard wedge interface has a “Y” interface cable with an AT male plug on one end and an AT female plug on the other. The cable end with the male plug is inserted into your computer’s keyboard port and your keyboard is plugged into the female plug. The MS146-3 operation should be “plug and play”. The MS146-3 has a built-in decoder that outputs the scanned data in Scancode keyboard format. Your computer will treat your MS146-3’s input as it would normal keyboard input. Note: If you are using a laptop computer or a USB keyboard (ie. you are not using an AT keyboard), then your MS146-3 will need to be configured as a “Keyboardless Wedge” (see “Device” in the “Scanner Configuration Manager” section. MS146-3PS2 and MS146I-3PS2 The PS/2 Keyboard Wedge interface is the most popular and straightforward. The MS146-3PS2 has a “Y” interface cable with a PS/2 male plug on one end and a PS/2 female plug on the other. The cable end with the male plug is inserted into your computer’s keyboard port (not the mouse port!) and your keyboard is plugged into the female plug. The MS146-3PS2 operation should be “plug and play”. The MS146-3PS2 has a built-in decoder that outputs the scanned data in Scancode keyboard format. Your computer will treat your MS146-3PS2’s input as it would normal keyboard input. Note: If you are using a laptop computer or a USB keyboard (ie. you are not using a PS/2 keyboard), then your MS146-3PS2 will need to be configured as a “Keyboardless Wedge” (see “Device” in the “Scanner Configuration Manager” section. MS146-4 and MS146I-4 The USB interface is becoming popular and relatively foolproof. Your MS146-4 uses the standard USB driver that has been included in the Windows Operating System since Windows 98 SE. The MS146-4 operation should be “plug and play”. The MS146-4 has a built-in decoder that outputs the scanned data in HID keyboard format. Your computer will treat your MS146-4’s input as it would normal keyboard input. Note: Mac OS10 users might need to update their USB driver.
2
MS146 Manual
Page 7
SCANNER CONFIGURATION MANAGER Scanner Configuration Manager software is the simplest and most foolproof way to configure your scanner settings.
Start it Up After loading and starting SCMSetup.exe the icon to the left will appear on your desktop: Click on the SCM icon and the following screen will appear: As you can see, you are presented with a blank work area and a row of icons across the top. Following is an explanation of each of the icons:
Above, from left to right, are the standard Windows icons for “New Document”, Open File”, and “Save File”. Scanner Configuration Manager saves scanner settings in .cfg files, so you can have access to a variety of different scanner configurations that you’ve set up. To reset the scanner back to factory default, click on the “New Document” icon and download the unmanipulated setting to the scanner (see below).
The above icons, from left to right, represent download settings (from computer to scanner), and upload settings (from scanner to computer). The third icon opens a Test Pad where you can view the actual scanner output. MS146 Manual
3
Page 8
The above four icons are used in the “Data Editing” feature of SCM. From left to right they are the “Add a Formula” icon, the “Remove a Formula” icon, and the right-hand two are the “Move Formula” icons that move selected formulas up or down in relation to each other. For information on data editing, see page 22.
Click this icon to print a series of bar codes that you can scan in order to configure your scanner to the current SCM settings. This option is especially useful if downloading to the scanner is not an option, like when using an interface adaptor or if Windows NT is your operating system. If you can produce PDF files via Acrobat, your SCM configuration can be sent via e-mail to remote locations where they can be scanned from a printed PDF file (without having to run SCM).
Help is just a click away.
Download to your Scanner Once you have SCM configured just the way you want it, click the Download icon (see page 3). The pop-up box to the right should appear: Select your appropriate interface: USB, RS232, or PS/2, and then click “OK”. The green LED on your scanner should blink and you should see the message “Download completed successfully”. Now your scanner is ready to use with its new configuration. If you should get the message “Download to scanner failed”, don’t dispair. You can still click the “Print” icon (see above) and scan in the resulting bar codes to configure your scanner.
4
MS146 Manual
Page 9
First Look Click the upload icon (see page 3) and the following pop-up screen will appear: (alternatively, you can click on the “New Document” icon, page 3, in which case the second screen will appear) Enter the scanner product number (MS146, for example). Make sure the “By Keyboard Interface” radio button is selected, and click “OK”. The LED on the top of the scanner will flash during the upload process.
The screen to the left appears. Click on any of the selections under “Current Settings” to view its “Attributes”.
Double-click on any of the “Attributes” to edit that attribute. This is done via a drop-down menu. After selecting your configuration settings, click on the Download icon (see page 3). The LED on the top of the scanner will flash during the download process. Afterwards, you will be prompted to do an optional “Quick Test”. MS146 Manual
5