Page 10

4 RS232 Serial Setting

Enter Group 4 Group Default

0

1

2

3

4

5

6

7

8

9

Review Exit 10

Page 11

Baud Rate: C1 0 1 2 3

300 600 1200 2400

4 5 6

4800 9600 19200

3 4

C2 Space None

Parity: 0 1 2

Even Odd Mark

Data Bit: C3 0

7

1

8

BCC character: C4 0

Off

1

On

2 3

C5 10 seconds No limit

Time Out: 0 1

1 second 3 seconds

11

Page 12

5 Scanner

Enter Group 5 Group Default

0

1

2

3

4

5

6

7

8

9

Review Exit 12

Page 13

Double verification: 0

D1 1

Off

On

Label Type: 0 Positive

D4 1 Positive and Negative

Output of Wand: D5 0 1

Bar High / Space Low Bar Low / Space High

Level Duration: 0

200 us

1

13

D6 600 us

Page 14

6 Data Format

Enter Group 6

0

Group Default

1

Review

2

Exit

3

Default Code ID Table SymSet1 Set2 bology UPC-A A A UPC-E E C EAN-13 F A EAN-8 FF B I 2 OF 5 I I S 2 OF 5 H H Code 39 M Y Codabar N N Code93 L L Code 128 K K MSI O M Code 11 J J If the “User Defined” option is selected, the default ID is Set1.

4

5

6

7

8

Data Format:

9

Preamble Code ID Length Terminator Postamble

Data BCC

14

Page 15

Terminator: 0 1

2 3

E1 Return(LF) None

2 3

E2 Default Set I Default Set II

Code 39 Full ASCII Code 39 Standard EAN-13 UPC-A EAN-8 UPC-E I 2 of 5

E3 07 Codabar 08 Code128 09 Code 93 10 S 2 of 5 11 MSI 12 Code 11 13

Enter (CR/LF) Field Exit(CR)

Code ID: 0 1

None User Defined

Define Code ID: 00 01 02 03 04 05 06

Data Length: 0

Exclude

1

E4 Include OO

PP

Postamble:

Preamble:

Scan “OO” to program preamble. Scan characters from Full ASCII table to define preamble. Maximum 16 characters. Scan “OO” to end.

Scan “PP” to program preamble. Scan characters from Full ASCII table to define preamble. Maximum 16 characters. Scan “PP” to end.

15

Page 16

7 Symbologies(I): Code 39/I2 of 5/ S2 of 5/Delta Distance Code/Code 32 Enter Group 7 Group Default

0

1

2

3

4

5

6

7

8

9

MM Minimum Length

NN Maximum Length

Review

Exit

Code 32: F5 0/1 2/3 4/5

Disable/Enable Leading Character Send / No Send Trailing Character Send /No Send

16

Page 17

Code 39: F1 0/1 Disable/Enable 2/3 Full ASCII/Standard 4 Check Digit Calculate and Send 5 Check Digit Calculate but Not Send 6 Check Digit Not Calculate 7/8 Send/Not Send Start & Stop 0~48 Min 0 / Max 48

Interleaved 2 of 5:

F2

0/1 Disable/Enable 2/3 Fix Length On/Off (by first three reads) 4 Check Digit Calculate and Send 5 Check Digit Calculate but Not Send 6 Check Digit Not Calculate 7 First Digit Suppressed. 8 Last Digit Not Suppressed. 9 Not Suppressed. 4~64 Min 10 / Max 64

Standard 2 of 5 / Toshiba:

F3

0/1 Disable/Enable 2/3 Fix Length On/Off 4 Check Digit Calculate and Send 5 Check Digit Calculate but Not Send 6 Check Digit Not Calculate 4~48 Min 8 / Max 48

Delta Distance Code: 0/1 2/3 4/5

F4

Disable/Enable Check Digit Not Send / Send Check Digit Calculate/Not Calculate

17

Page 18

8 Symbologies(II): Code 128 / MSI / Code 93 / Codabar /Label Code Enter Group 8

Group Default

0

1

2

3

4

5

6

7

8

9

MM Minimum Length

NN Maximum Length

Review

Exit

18