Page 81
Keyboard wedge - Additional preamble / postamble characters ARROW UP
ARROW DOWN
CLEAR
FIELD -
DUP
ESC
LINE FEED
RESET
End Selection
MB/NX/RM/00/E/970131
71
Page 82
Keyboard wedge - Emulating special keyboard keys
Keyboard wedge - Emulating special keyboard keys Interpreting and transmitting special keyboard keys Different symbologies support different character formats. The MicroBar NX transmission format is different according to the symbologies used (Ð Symbologies - Character formats and MicroBar NX transmission format ).
Only symbologies supporting the full ASCII character set allow the encoding of certain special keyboard keys such as <Return> and <Tab>. No symbologies support the encoding of other function keys such as <PF1> and <PageDown>. The Special keys interpretation codes provided below allow you to interpret different Code 39 character combinations as special keyboard keys. The Special keys transmission codes allow you to emulate Alt character transmission sequences for PC keyboard wedge applications. Example code read (Code 39 code) x x x x x. L x x x interpreted as transmitted as x x x x x. L x x x x x x x x. L x x x
Special keys interpretation
Special keys transmission x x x x x <Backspace> x x x (full ASCII symbology code) x x x x x <Backspace> x x x
72 x x x x x <Backspace> x x x x x x x x <Ctrl> H x x x or x x x x x <Backspace> x x x
MB/NX/RM/00/E/970131
Page 83
Keyboard wedge - Emulating special keyboard keys Special keys interpretation codes You can emulate special keyboard keys for Code 39 bar codes containing dual-character combinations as shown in the Code 39 keyboard emulation chart on the next page. The MicroBar NX must be enabled to read Code 39 codes with the appropriate barcode length setting (Ð Symbologies - Code 39). 1 - Not Active (*)
2 - Always Active
3 - Only Active If Separate 2-Character Label Or If Preceded By A Hyphen ( - )
4 - Only Active If Separate 2-Character Label
Example original Code 39 bar code with . L dual characters (<Backspace>)
interpreted and transmitted as:
code39.L12
1 - not activeCODE39.L12 2 - always activeCODE312 3 - separate 2 characters or hyphenCODE39.L12 4 - separate 2 charsCODE39.L12 code39-.L12
1 - not activeCODE39-.L12 2 - always activeCODE3912 3 - separate 2 chars or hyphenCODE312 4 - separate 2 charsCODE39-.L12
--.L
1 - not active--.L 2 - always active3 - separate 2 chars or hyphen 4 - separate 2 chars--.L
.L
1 - not active.L 2 - always activ 3 - separate 2 chars or hyphe 4 - separate 2 char
MB/NX/RM/00/E/970131
73
Page 84
Keyboard wedge - Emulating special keyboard keys Code 39 keyboard emulation chart emulated keys
74 character combination emulated keys character combination
DEL
.A
PF1
0A
ENTER
.B
PF2
0B
RETURN
.C
PF3
0C
SEND
.D
PF4
0D
FIELD +
.E
PF5
0E
FIELD EXIT
.F
PF6
0F
HOME
.G
PF7
0G
END
.H
PF8
0H
TAB
.I
PF9
0I
ALT
.J
PF10
0J
BACK TAB
.K
PF11
0K
BACK SPACE
.L
PF12
0L
⇒
.M
PF13
0M
⇐
.N
PF14
0N
⇑
.O
PF15
0O
⇓
.P
PF16
0P
CLEAR
.Q
PF17
0Q
FIELD -
.R
PF18
0R
DUP
.S
PF19
0S
ESC
.T
PF20
0T
LINE FEED
.U
PF21
0U
RESET
.V
PF22
0V
CTRL
.W
PF23
0W
SPECIAL
.X
PF24
0X
MB/NX/RM/00/E/970131
Page 85
Keyboard wedge - Emulating special keyboard keys Special keys transmission codes Alt mode transmission Alt Mode On emulates the [<Alt>+decimal_number_sequence] function available on PC AT keyboards and can be used to transmit ASCII characters that are not available on the keyboard corresponding to your interface number. If you read bar codes containing such characters, you will be able to transmit the characters if you select Alt Mode On. Only use Alt mode if necessary, as all characters will be transmitted as <Alt> sequences and transmission will be slightly slower. Alt Mode Off (*)
Alt Mode On
MB/NX/RM/00/E/970131
75
Page 86
Laser scanner input devices
Laser scanner input devices Laser trigger management RS-232 trigger You can activate some laser scanners by transmitting a user-defined RS-232 character from the host system (software activation). Scan Compose Activation Character and scan the ASCII character you want to use as the RS-232 trigger.
Not Active (*)
Compose Activation Character
CTS trigger Low Level Active or High Level Active activates the scanner according to the level of the CTS signal received (voltage level activation).
Not Active (*)
Low Level Active
High Level Active
76
MB/NX/RM/00/E/970131
Page 87
Laser scanner input devices Laser timeout before deactivation Laser scanners normally remain active until the trigger is released or a timeout period is reached. The laser timeout codes allow the MicroBar NX to control the timeout period before deactivation and are valid for all laser trigger configurations.
2 sec (*)
1 sec
3 sec
8 sec
Marker beam The marker beam is a spot of light to make aiming easier. Marker Beam On activates the laser scanner marker beam when the trigger is pressed. Marker beam is only available for UBI ScanImage 9x0 and QuickScan laser scanners equipped with a special cable.
Marker Beam Off (*)
Marker Beam On
MB/NX/RM/00/E/970131
77
Page 88
Laser scanner input devices Autostand mode Autostand On sets the laser scanner to trigger automatically when a bar code is presented. Autostand mode is only available for UBI ScanImage 9x0 and QuickScan laser scanners equipped with a special stand and cable.
Autostand Off (*)
Autostand On
“Code not read” message This function informs the host system if the barcode data has not been successfully decoded when the trigger is released or the timeout period is reached - particularly useful to indicate unread codes when scanners are used in autostand mode for example (see above). To define the character used to indicate a non-read, scan Compose ASCII Character and scan an ASCII character (ÐASCII character codes ). To define the number of non-read characters you want to send, scan Compose Repetition Number, scan a number between 1 and 20 and scan End Selection (Ð Number codes or inside back cover of this manual).
Not Active (*)
Compose ASCII Character
Compose Repetition Number (max = 20)
78
MB/NX/RM/00/E/970131
Page 89
Laser scanner input devices Consecutive same read data validation Consecutive same read data validation is useful when increased data security is required - in particular when you read poorly printed codes, codes with variable lengths and without check digits, "fragile" barcode types. To increase the reliability of the data transmitted, you can set the MicroBar NX to validate the data before it is transmitted - it will only transmit data after a specified number of successful consecutive reads have given the same result. For certain "fragile" symbologies, you can also increase the reliability of the barcode data transmitted by configuring the MicroBar NX to transmit data for codes of 1, 2 or 3 fixed lengths only (Ð Symbologies - Barcode length and data security ). By default, transmission occurs after a single successful read. Increasing the number of consecutive same reads before transmission decreases the decoding rate.
Single Read Before Transmission (*)
Compose number of consecutive same reads before transmission Compose Number of Consecutive Same Reads Before Transmission (maximum = 10)
Example
To make your MicroBar NX decode the same code successfully 5 times before it can transmit it: 1. Scan Compose Number of Consecutive Same Reads Before Transmission. 2. Scan 5 then scan End Selection ( Ð Number codes or inside back cover of this manual).
MB/NX/RM/00/E/970131
79
Page 90
Magstripe input devices
Magstripe input devices Track selection The MicroBar NX can read 1 track or 2 tracks from a possible total of 1, 2, or 3 tracks.
Read All Tracks (*)
Track 1 Or 3
Track 2
Tracks 1 And 2
Tracks 2 And 3
80