Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 21

MicroBar NX Reference Manual, pages 31 to 40

Pages 31 to 40 of 202

The original document is the PDF (718 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the UBI NX

Page 31

Code mark AIM symbology identifiers AIM symbology identifiers are optional 3-character code marks that have been standardized by the AIM Committee. AIM symbology identifiers are transmitted after the preamble if present and before the barcode data. Selecting AIM Transmitted automatically activates transmission for all symbologies.

AIM symbology identifier

M AIM symbology identifiers should only be activated for keyboard wedge and RS-232 interfaces.

AIM Not Transmitted (*)

AIM Transmitted

Identifier syntax

AIM symbology identifiers consist of 3 characters which provide the following information:

Example

• the character " ] " indicates that the input source type is a bar code,

• a letter (A, B, C, . . . ) identifies the symbology,

• a hexadecimal number identifies any special processing performed by the MicroBar NX.

If you select AIM Transmitted, a standard Code 39 code without check digit and containing the string CODE-39 will be transmitted as follows: ]A0CODE-39

The table on the next page provides the list of symbology identifiers and processing options supported. MB/NX/RM/00/E/970131

21

Page 32

Code mark AIM symbology identifiers / supported processing options Not all the special processing options are supported. Refer to the official AIM documentation on symbology identifiers for full information on the different processing options.

symbology

22

AIM symbology identifier

AIM processing options

Ames Code

X

0

Codabar

F

0, 2, 4

Code 11

H

0, 1, 2

Code 39

A

0, 1, 2, 4

Code 93

G

0

Code 128 / EAN 128

C

0, 1

Interleaved 2 of 5

I

0, 1, 2

Matrix 2 of 5

X

0

Standard 2 of 5

S

0, 1, 2

MSI Code

M

0, 1

Plessey Code

P

0

Telepen

B

0, 1

UPC/EAN, "standard" lengths (8, 13, 15 (add-on 2), 18 (add-on 5) characters)

E

0, 3, 4

UPC/EAN, other lengths (no check digit, . . .)

X

0

MB/NX/RM/00/E/970131

Page 33

Compose interface number

Compose interface number Which interface number? To know which interface number to enter, check the following points in the order shown: 1. Look to see if there is a suitable number in the Predefined interface numbers section for your host system hardware configuration. 2. Look to see if your configuration is described in the MicroBar NX Terminal List (if available). 3. If you still do not know which number to enter, contact your UBI representative. Entering an interface number usually only modifies data transmission parameter settings but in some special cases, other parameter settings (beep/LED settings, symbologies, etc.) may be modified for specific interface configurations. Do not enter an interface number that is not compatible with your host system interface.

Composing an interface number Example

To enter the number 102: 1. Scan Compose Host System Interface Number on the next page. 2. Scan 1, then 0, then 2. 3. Scan End Selection to finish.

MB/NX/RM/00/E/970131

23

Page 34

Compose interface number 1

2

3

4

5

6

7

8

9

0

Compose Host System Interface Number

24

End Selection

MB/NX/RM/00/E/970131

Page 35

Concatenating configuration bar codes

Concatenating configuration bar codes What is a configuration bar code? All the configuration codes in this Reference Manual are Code 128 bar codes with a special terminator character - FNC3, data string \60 - to indicate that the code is a configuration code.

Why concatenate? In order to configure the MicroBar NX for a given installation, you may need to read a number of configuration codes one after the other - and you may need to do this for each MicroBar NX you have to install and set up. Many of the configuration bar codes in this manual can be concatenated (combined) to form a single custom bar code which corresponds to your own particular setup configuration - you then only need to read 1 or 2 concatenated codes instead of a whole series of codes.

Limitations Do not create concatenated codes wider than the maximum reading width of your bar code reader. If you need to create more than one code for a series of configuration codes, always end each concatenated code with a complete configuration code - not a partial code - and the FNC3 terminator. You can not concatenate configuration codes that use the Number codes to compose numerical values.

How to concatenate 1. Identify the list of codes you want to concatenate and the order of concatenation - the codes should be concatenated in the same order as you would read them individually. Example

If you need to enter Reset Factory Defaults, put this code at the beginning.

MB/NX/RM/00/E/970131

25

Page 36

Concatenating configuration bar codes 2. Obtain the data strings for the codes you want to concatenate (Ð Parameter list / data strings). Example

For the following codes, you will obtain the following strings: reset factory defaults

\46\42\60

N° 201

\41\4A\03\09\60

AZERTY - French

Codabar active

\41\52\60

2 good read beeps

\45\4A\01\60

You can also obtain the data strings by putting the MicroBar NX into Display Data String mode and reading the configuration codes of your choice (Ð Configuration modes - Display data string mode). However, the strings displayed include a check digit after the \60 end-ofcode character which you must also remove when you concatenate the codes.

3. Use the individual data strings to create a single data string and remove the \60 end-of-code characters for each code except the last code in the string. Example

For the codes listed in the previous example, you will obtain the following concatenated string: \46\42\41\4A\03\09\41\52\45\4A\01\60

4. If necessary, convert the hexadecimal values and backslash separators into suitable values for your barcode printing sofware (ASCII values for example). The data strings contain hexadecimal values separated by backslashes. Make sure that the values you use with your software correspond to these values. Example: Instead of the hexadecimal value \41, you may need to use the equivalent ASCII character "A" (do not use the decimal value 41 !).

26

MB/NX/RM/00/E/970131

Page 37

Configuration modes

Configuration modes Cloning mode This mode allows you to copy the configuration setup from one MicroBar NX to another MicroBar NX - useful if you want to set up a number of MicroBar NX models with the same configuration for example. 1. Connect the special cloning cable to port 3 of each MicroBar NX unit (ask your UBI representative for details if you do not have this cable). 2. Scan Source - Copy From with a barcode reader connected to the MicroBar NX containing the configuration you want to copy. 3. Scan Target - Copy To with a barcode reader connected to the MicroBar NX which is to receive the new configuration.

Source - Copy From

Target - Copy To

MB/NX/RM/00/E/970131

27

Page 38

Configuration modes Configuration Password mode The configuration password protects the MicroBar NX against unauthorized configuration. When the password is activated, the MicroBar NX will only save the configuration if you have scanned a Code 39 bar code containing the password - if you do not read the password, your new configuration will be lost when you switch off the MicroBar NX. Password format:

* char1 char2 char3 $ *

*

Code 39 start/stop character

$ obligatory fourth character, generated automatically char1, char2 and char3 are user-defined password characters To deactivate the password 1. Read the correct password code. 2. Scan Not Active. Make sure that your barcode reader and MicroBar NX are configured to read Code 39 barcode labels before you read the password code you have created.

Not Active (*)

Compose Password

Example

To create a bar code with the password “R V B $” : 1. Scan Compose Password. 2. Scan the characters “R”, “V”, and “B” and scan End Selection to finish (ÐASCII character codes ). 3. Print the Code 39 label with your printer.

28

MB/NX/RM/00/E/970131

Page 39

Configuration modes Temporary configuration mode Temporary Configuration Mode allows you to test new configuration settings without losing your current configuration setup. Temporary configuration mode remains active until you select Restore/Update Current Configuration or until you switch off the MicroBar NX. Temporary Configuration Mode

Restore current configuration Restore Current Configuration quits temporary configuration mode and returns the MicroBar NX to its current configuration settings. Restore Current Configuration

Update current configuration Update Current Configuration replaces the current configuration settings with the new settings entered in temporary configuration mode. The MicroBar NX quits temporary configuration mode. Update Current Configuration

MB/NX/RM/00/E/970131

29

Page 40

Configuration modes ScanPlus transparent configuration mode Using a ScanPlus to configure your MicroBar NX If you use UBI’s ScanPlus barcode reader (in wand or laser emulation) to configure your MicroBar NX, you must first read the ScanPlus Transparent Configuration Mode configuration code - otherwise you will configure the ScanPlus and not the MicroBar NX! ScanPlus transparent configuration mode remains active until you switch off the ScanPlus. ScanPlus Transparent Configuration Mode

Example

To use a ScanPlus to configure the MicroBar NX: 1. Connect the ScanPlus in wand emulation mode to the MicroBar NX. 2. Scan ScanPlus Transparent Configuration Mode. 3. Use your ScanPlus to scan the desired configuration codes for interpretation by the MicroBar NX. 4. Switch off the ScanPlus to deactivate Transparent Configuration Mode.

30

MB/NX/RM/00/E/970131