Page 191

Symbologies - UPC/EAN code families (*) Check digit UPC/EAN code format: <leading character> <number system> <data> <check digit>

UPC-A check digit Transmitted (*)

Not Transmitted

UPC-E check digit Transmitted (*)

Not Transmitted

EAN-8 check digit Transmitted (*)

Not Transmitted

EAN-13 check digit Transmitted (*)

Not Transmitted

MB/NX/RM/00/E/970131

181

Page 192

Symbologies - UPC/EAN code families (*) Transmission of number system UPC/EAN code format: <leading character> <number system> <data> <check digit> A regular UPC-A has a transmitted number system equal to 0. To transmit the additional leading character (country code), select the parameter UPC-A Transmitted As EAN-13.

UPC-A number system Transmitted (*)

Not Transmitted

UPC-E number system Transmitted (*)

Not Transmitted

182

MB/NX/RM/00/E/970131

Page 193

Symbologies - UPC/EAN code families (*) Re-encoding UPC-A, UPC-E, EAN-8 These parameters convert the decoded data to other code formats. Transmission will only take into account the parameters available for the target bar code format. UPC/EAN code format: <leading character> <number system> <data> <check digit> A regular UPC-A has a transmitted number system equal to 0. To transmit the additional leading character (country code), select the parameter UPC-A Transmitted As EAN-13. UPC-A Transmitted as EAN-13 (*)

UPC-A Transmitted as UPC-A

UPC-E Transmitted as UPC-E (*)

UPC-E Transmitted as UPC-A

EAN-8 Transmitted as EAN 8 (*)

EAN-8 Transmitted as EAN-13

MB/NX/RM/00/E/970131

183

Page 194

Test codes

Test codes One-dimensional symbologies Codabar

123456 Code 39

CODE-39 Code 93

CODE-93 Code 128

CODE-128 EAN 128

]C1EAN 128 Interleaved 2 of 5

12345678901234 Standard 2 of 5

123456 Matrix 2 of 5

012345

184

MB/NX/RM/00/E/970131

Page 195

Test codes MSI Code

12345666 Plessey Code

80001495050 EAN-8

12345670 EAN-13

1234567890128 UPC-A

0

01234 50000

7

UPC-E

0

MB/NX/RM/00/E/970131

012345 7

185

Page 196

Troubleshooting

Troubleshooting Before you contact your UBI representative . . . The tables in this section describe some common problems you may encounter when you use your MicroBar NX (power-up, normal operation, configuration). Look for a description of your problem in the symptoms columns and try the proposed solution given in the action column. If you do not find a solution in the following Troubleshooting tables, you can try a general reset of the MicroBar NX (Ð Reset all configuration parameters ). If you can not solve the problem yourself, please contact your UBI representative.

If you still have a problem . . . Contact your UBI representative and give full details of the problem. Your UBI representative may ask you to provide the software version number for your MicroBar NX. If the MicroBar NX is powered up, try to read the Software Version code to display this information on your host system screen if applicable (Ð Software version identification).

186

MB/NX/RM/00/E/970131

Page 197

Troubleshooting Power-up problems symptoms no power-up beeps / red power-up LED green LED flashes a number of times at power-up possible causes action (

Ðrefer to)

• no electrical power or insufficient electrical power check power supply

• connection problems check connections (Connection diagram for your interface)

• incorrect product components (MicroBar NX, cables, external power supply as applicable)

check product part numbers, order form and invoice + Connection diagram for your interface, Interfaces number of flashes indicate the selected interface type

• check the number of flashes for your interface (Interfaces)

• reselect correct interface number for your system if necessary (Predefined interface numbers section for your interface, Compose interface number) and reconfigure too many green LED flashes additional flash due to power surge at at power-up in spite of correct power-up interface type selected check that additional flash is at beginning and separate from other "normal" flashes (if applicable)

continuous green LED at power-up scan the predefined interface number code for your system (Predefined interface numbers section for your interface) or enter the correct interface number (Compose interface number) and reconfigure null interface following Reset Factory Defaults error beeps from keyboard host system already switched on when connecting MicroBar NX wait a few seconds - the beeps should stop

3 long beeps then 5 short beeps at power-up contact your UBI representative

MB/NX/RM/00/E/970131

EEPROM integrity error

187

Page 198

Troubleshooting Operating problems symptoms no beeps or green indicator LED during reading, no transmission possible causes

188

Ðrefer to)

• installation problem check MicroBar NX power supply, connections (Connection diagram for your interface), product components

• configuration problem

• check you have the correct product components (MicroBar NX, cables, external power supply as applicable)

• check you have the correct number of flashes for your interface at power-up (Interfaces)

• reselect correct interface number for your system if necessary (Predefined interface numbers section for your interface, Compose interface number)

• if you have just configured the MicroBar NX, make sure you have finished correctly - the MicroBar NX may be waiting for an End Selection for example

• symbology not selected activate the required symbology (Symbologies - Activation)

• symbology not supported by the MicroBar NX see the MicroBar NX data sheet, read the appropriate test code (Test codes)

• good read beep / LED deactivated activate if required (Beeps and LEDs)

• barcode length incompatible with MicroBar NX configuration (fixed length parameter settings)

• error beeps from keyboard or no manual keyboard response (keyboard wedge interface)

action (

• check bar code

• change barcode length setting for your symbology if applicable (Symbologies)

MicroBar NX configured for check • digit and no check digit present in • code check bar code change check digit configuration for your symbology if applicable (Symbologies)

disconnect MicroBar NX: • if problem disappears, the problem is with the MicroBar NX check MicroBar NX configuration

MB/NX/RM/00/E/970131

Page 199

Troubleshooting

MicroBar NX transmits different data for the same bar code

MB/NX/RM/00/E/970131

• if problem remains . . .

check all product components (MicroBar NX, cables, power supply as applicable), installation and configuration

•

MicroBar NX interprets part of the label as a different code (different symbology)

scan Disable All Symbologies and only activate the symbologies you need (Symbologies - Activation)

•

MicroBar NX interprets part of the label as a separate code (smaller code inside the label)

use the Define 1 Or 2 Or 3 Fixed Lengths parameter if available (Symbologies - Barcode length and data security and Barcode Length section for your symbology if applicable)

• insufficient number of data validation reads (code damaged or poorly printed)

increase number of consecutive same reads before transmission (Laser scanner input devices - Consecutive same read data validation)

189

Page 200

Troubleshooting Configuration problems symptoms possible causes

6 short beeps when reading a configuration error: configuration code • option not available • interface number not available

• optional feature not implemented

• commands not read in the correct order

• other setup errors no success beeps / green • indicator LED when reading a configuration code installation problem action (

Ðrefer to)

check current action - make sure in particular that you have scanned End Selection once or twice if required for the previous parameter check MicroBar NX power supply, connections (Connection diagram for your interface), product components code mark selection not taken you forgot to scan End Selection after re-enter the desired code mark (Code into account scanning the desired ASCII character mark) and scan End Selection (ASCII character codes) 3 long beeps then 5 short beeps during configuration

190

EEPROM integrity error contact your UBI representative

MB/NX/RM/00/E/970131