The text of a manual · part 20 of 21
MicroBar NX Reference Manual, pages 191 to 200
Pages 191 to 200 of 202
The original document is the PDF (718 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the UBI NX
Page 191
Symbologies - UPC/EAN code families (*) Check digit UPC/EAN code format: <leading character> <number system> <data> <check digit>
UPC-A check digit Transmitted (*)
Not Transmitted
UPC-E check digit Transmitted (*)
Not Transmitted
EAN-8 check digit Transmitted (*)
Not Transmitted
EAN-13 check digit Transmitted (*)
Not Transmitted
MB/NX/RM/00/E/970131
181
Page 192
Symbologies - UPC/EAN code families (*) Transmission of number system UPC/EAN code format: <leading character> <number system> <data> <check digit> A regular UPC-A has a transmitted number system equal to 0. To transmit the additional leading character (country code), select the parameter UPC-A Transmitted As EAN-13.
UPC-A number system Transmitted (*)
Not Transmitted
UPC-E number system Transmitted (*)
Not Transmitted
182
MB/NX/RM/00/E/970131
Page 193
Symbologies - UPC/EAN code families (*) Re-encoding UPC-A, UPC-E, EAN-8 These parameters convert the decoded data to other code formats. Transmission will only take into account the parameters available for the target bar code format. UPC/EAN code format: <leading character> <number system> <data> <check digit> A regular UPC-A has a transmitted number system equal to 0. To transmit the additional leading character (country code), select the parameter UPC-A Transmitted As EAN-13. UPC-A Transmitted as EAN-13 (*)
UPC-A Transmitted as UPC-A
UPC-E Transmitted as UPC-E (*)
UPC-E Transmitted as UPC-A
EAN-8 Transmitted as EAN 8 (*)
EAN-8 Transmitted as EAN-13
MB/NX/RM/00/E/970131
183
Page 194
Test codes
Test codes One-dimensional symbologies Codabar
123456 Code 39
CODE-39 Code 93
CODE-93 Code 128
CODE-128 EAN 128
]C1EAN 128 Interleaved 2 of 5
12345678901234 Standard 2 of 5
123456 Matrix 2 of 5
012345
184
MB/NX/RM/00/E/970131
Page 195
Test codes MSI Code
12345666 Plessey Code
80001495050 EAN-8
12345670 EAN-13
1234567890128 UPC-A
0
01234 50000
7
UPC-E
0
MB/NX/RM/00/E/970131
012345 7
185
Page 196
Troubleshooting
Troubleshooting Before you contact your UBI representative . . . The tables in this section describe some common problems you may encounter when you use your MicroBar NX (power-up, normal operation, configuration). Look for a description of your problem in the symptoms columns and try the proposed solution given in the action column. If you do not find a solution in the following Troubleshooting tables, you can try a general reset of the MicroBar NX (Ð Reset all configuration parameters ). If you can not solve the problem yourself, please contact your UBI representative.
If you still have a problem . . . Contact your UBI representative and give full details of the problem. Your UBI representative may ask you to provide the software version number for your MicroBar NX. If the MicroBar NX is powered up, try to read the Software Version code to display this information on your host system screen if applicable (Ð Software version identification).
186
MB/NX/RM/00/E/970131
Page 197
Troubleshooting Power-up problems symptoms no power-up beeps / red power-up LED green LED flashes a number of times at power-up possible causes action (
Ðrefer to)
• no electrical power or insufficient electrical power check power supply
• connection problems check connections (Connection diagram for your interface)
• incorrect product components (MicroBar NX, cables, external power supply as applicable)
check product part numbers, order form and invoice + Connection diagram for your interface, Interfaces number of flashes indicate the selected interface type
• check the number of flashes for your interface (Interfaces)
• reselect correct interface number for your system if necessary (Predefined interface numbers section for your interface, Compose interface number) and reconfigure too many green LED flashes additional flash due to power surge at at power-up in spite of correct power-up interface type selected check that additional flash is at beginning and separate from other "normal" flashes (if applicable)
continuous green LED at power-up scan the predefined interface number code for your system (Predefined interface numbers section for your interface) or enter the correct interface number (Compose interface number) and reconfigure null interface following Reset Factory Defaults error beeps from keyboard host system already switched on when connecting MicroBar NX wait a few seconds - the beeps should stop
3 long beeps then 5 short beeps at power-up contact your UBI representative
MB/NX/RM/00/E/970131
EEPROM integrity error
187
Page 198
Troubleshooting Operating problems symptoms no beeps or green indicator LED during reading, no transmission possible causes
188
Ðrefer to)
• installation problem check MicroBar NX power supply, connections (Connection diagram for your interface), product components
• configuration problem
• check you have the correct product components (MicroBar NX, cables, external power supply as applicable)
• check you have the correct number of flashes for your interface at power-up (Interfaces)
• reselect correct interface number for your system if necessary (Predefined interface numbers section for your interface, Compose interface number)
• if you have just configured the MicroBar NX, make sure you have finished correctly - the MicroBar NX may be waiting for an End Selection for example
• symbology not selected activate the required symbology (Symbologies - Activation)
• symbology not supported by the MicroBar NX see the MicroBar NX data sheet, read the appropriate test code (Test codes)
• good read beep / LED deactivated activate if required (Beeps and LEDs)
• barcode length incompatible with MicroBar NX configuration (fixed length parameter settings)
• error beeps from keyboard or no manual keyboard response (keyboard wedge interface)
action (
• check bar code
• change barcode length setting for your symbology if applicable (Symbologies)
MicroBar NX configured for check • digit and no check digit present in • code check bar code change check digit configuration for your symbology if applicable (Symbologies)
disconnect MicroBar NX: • if problem disappears, the problem is with the MicroBar NX check MicroBar NX configuration
MB/NX/RM/00/E/970131
Page 199
Troubleshooting
MicroBar NX transmits different data for the same bar code
MB/NX/RM/00/E/970131
• if problem remains . . .
check all product components (MicroBar NX, cables, power supply as applicable), installation and configuration
•
MicroBar NX interprets part of the label as a different code (different symbology)
scan Disable All Symbologies and only activate the symbologies you need (Symbologies - Activation)
•
MicroBar NX interprets part of the label as a separate code (smaller code inside the label)
use the Define 1 Or 2 Or 3 Fixed Lengths parameter if available (Symbologies - Barcode length and data security and Barcode Length section for your symbology if applicable)
• insufficient number of data validation reads (code damaged or poorly printed)
increase number of consecutive same reads before transmission (Laser scanner input devices - Consecutive same read data validation)
189
Page 200
Troubleshooting Configuration problems symptoms possible causes
6 short beeps when reading a configuration error: configuration code • option not available • interface number not available
• optional feature not implemented
• commands not read in the correct order
• other setup errors no success beeps / green • indicator LED when reading a configuration code installation problem action (
Ðrefer to)
check current action - make sure in particular that you have scanned End Selection once or twice if required for the previous parameter check MicroBar NX power supply, connections (Connection diagram for your interface), product components code mark selection not taken you forgot to scan End Selection after re-enter the desired code mark (Code into account scanning the desired ASCII character mark) and scan End Selection (ASCII character codes) 3 long beeps then 5 short beeps during configuration
190
EEPROM integrity error contact your UBI representative
MB/NX/RM/00/E/970131