Page 131
RS-232 input devices Dual-character combinations 1 - Not Active (*)
2 - Always Active
3 - Only Active If Separate 2-Character Label Or If Preceded By A Hyphen ( - )
4 - Only Active If Separate 2-Character Label
Single character with ASCII value > 7Fh You must select Data Bits = 8 for the RS-232 input device if you want to use Only Active If Separate 8-Bit Character Label (Ð RS-232 - Input device - Data bits ).
5 - Only Active If Separate 8-Bit Character Label
MB/NX/RM/00/E/970131
121
Page 132
RS-232 input devices RS-232 input - Keyboard emulation chart emulated keys dual-character combination single character > 7Fh emulated keys dual-character combination single character > 7Fh
DEL
.A
80h
PF1
0A
98h
ENTER
.B
81h
PF2
0B
99h
RETURN
.C
82h
PF3
0C
9Ah
SEND
.D
83h
PF4
0D
9Bh
FIELD +
.E
84h
PF5
0E
9Ch
FIELD EXIT
.F
85h
PF6
0F
9Dh
HOME
.G
86h
PF7
0G
9Eh
END
.H
87h
PF8
0H
9Fh
TAB
.I
88h
PF9
0I
A0h
ALT
.J
89h
PF10
0J
A1h
BACKTAB
.K
8Ah
PF11
0K
A2h
BACKSPACE
.L
8Bh
PF12
0L
A3h
⇒
.M
8Ch
PF13
0M
A4h
⇐
.N
8Dh
PF14
0N
A5h
⇑
.O
8Eh
PF15
0O
A6h
⇓
.P
8Fh
PF16
0P
A7h
CLEAR
.Q
90h
PF17
0Q
A8h
FIELD -
.R
91h
PF18
0R
A9h
DUP
.S
92h
PF19
0S
AAh
ESC
.T
93h
PF20
0T
ABh
LINE FEED
.U
94h
PF21
0U
ACh
RESET
.V
95h
PF22
0V
ADh
CTRL
.W
96h
PF23
0W
AEh
SPECIAL
.X
97h
PF24
0X
AFh
122
MB/NX/RM/00/E/970131
Page 133
RS-232 input devices UDI / CICS For special keyboard wedge applications, the MicroBar NX converts ASCII character FF (0Ch) to wedge character ENTER and ASCII character DC1 (11h) to wedge character TAB.
Not Active (*)
Active
MB/NX/RM/00/E/970131
123
Page 134
RS-232 - Output to host system
RS-232 - Output to host system Connection - RS-232 C, RS-232 TTL serial port host system
Ø • undecoded pen • low-power wand emulation device (< 50 mA) 5V power supply (modular plug)
2
5V power supply (jack)
3
1
4 input device
1. Switch off the host system. 2. Use the RS-232 cable to connect the MicroBar NX to the host system. 3. Connect your data input devices to the MicroBar NX. 4. Connect the external power supply (jack or modular plug) to the MicroBar NX. 5. Plug the power supply into the mains socket. 6. Switch on the host system.
M Do not switch on the host system until you have connected up and plugged in the external power supply.
124
MB/NX/RM/00/E/970131
Page 135
RS-232 - Output to host system Connection - Dual RS-232 C The default hardware configuration of the MicroBar NX transmits data on the DTE connector (to host) only.
serial port serial port
×
Ø host system terminal terminal
Ï DCE
DTE
Ð host • undecoded pen • low-power wand emulation device (< 50 mA)
5V power supply (modular plug)
2
5V power supply (jack)
3
1
4 input device
1. Switch off the host system. 2. Disconnect the terminal from the host system. 3. Use the dual RS-232 cable to connect the MicroBar NX between the terminal and the host system. 4. Connect your data input devices to the MicroBar NX. 5. Connect the external power supply (jack or modular plug) to the MicroBar NX. 6. Plug the power supply into the mains socket. 7. Switch on the host system.
M Do not switch on the host system until you have connected up and plugged in the external power supply. MB/NX/RM/00/E/970131
125
Page 136
RS-232 - Output to host system Predefined interface numbers If your interface number is not among the predefined interface numbers, you must compose the number yourself (Ð Compose interface number ).
Predefined interface numbers - RS-232 N° 100 - Standard RS-232 C (9600, 7, E, 2)
N° 101 - RS-232 TTL Level
N° 102 - RS-232 PC Term
N° 105 - RS-232 Slave Mode
Ð RS-232 - Slave mode
126
MB/NX/RM/00/E/970131
Page 137
RS-232 - Output to host system Predefined data transmission settings Predefined settings for RS-232 - Interface N° 100 baud rate
-
9600 data bits
-
7 parity
- even stop bits
-
2 time-out (hardware and software)
-
1000 ms
ENQ (Hex 05)
- not used
ACK (Hex 06)
- not used
NAK (Hex 15)
- not used
XON/XOFF (software)
- inactive
RTS/CTS (hardware)
- inactive
RTS/CTS management
- low RTS idle
LRC (longitudinal redundancy check)
- inactive preamble
- none postamble
-
Carriage Return + Line Feed inter-character delay
- none inter-message delay
- none
In this section, the predefined parameter settings for interface N° 100 (Standard RS-232) are indicated by an asterisk (*).
MB/NX/RM/00/E/970131
127
Page 138
RS-232 - Output to host system Baud Rate 9600 (*)
75
150
300
600
1200
2400
4800
19200
38400
128
MB/NX/RM/00/E/970131
Page 139
RS-232 - Output to host system Data bits Seven (*)
Eight
Parity Even (*)
Odd
Mark
Space
None
Stop bits Two (*)
One
MB/NX/RM/00/E/970131
129
Page 140
RS-232 - Output to host system Hardware/software protocols timeout The same timeout value applies to all the RS-232 protocols supported by the MicroBar NX: •
ENQ / ACK / NAK software protocol,
•
XON / XOFF software protocol,
•
RTS / CTS hardware protocol.
1000 ms (*)
Unlimited Timeout (value = 0)
Compose timeout Compose Timeout (minimum = 1 ms, maximum = 2500 ms)
Example
To set a hardware and software timeout of 2 seconds (= 2000 ms): 1. Scan Compose Timeout. 2. Scan the desired value in milliseconds - in our example we would scan 2 0 0 0 (Ð Number codes or inside back cover of this manual). 3. Scan End Selection to finish.
130
MB/NX/RM/00/E/970131