RS-232 input devices Dual-character combinations 1 - Not Active (*)

2 - Always Active

3 - Only Active If Separate 2-Character Label Or If Preceded By A Hyphen ( - )

4 - Only Active If Separate 2-Character Label

Single character with ASCII value > 7Fh You must select Data Bits = 8 for the RS-232 input device if you want to use Only Active If Separate 8-Bit Character Label (Ð RS-232 - Input device - Data bits ).

5 - Only Active If Separate 8-Bit Character Label

MB/NX/RM/00/E/970131

121

Page 132

RS-232 input devices RS-232 input - Keyboard emulation chart emulated keys dual-character combination single character > 7Fh emulated keys dual-character combination single character > 7Fh

DEL

.A

80h

PF1

0A

98h

ENTER

.B

81h

PF2

0B

99h

RETURN

.C

82h

PF3

0C

9Ah

SEND

.D

83h

PF4

0D

9Bh

FIELD +

.E

84h

PF5

0E

9Ch

FIELD EXIT

.F

85h

PF6

0F

9Dh

HOME

.G

86h

PF7

0G

9Eh

END

.H

87h

PF8

0H

9Fh

TAB

.I

88h

PF9

0I

A0h

ALT

.J

89h

PF10

0J

A1h

BACKTAB

.K

8Ah

PF11

0K

A2h

BACKSPACE

.L

8Bh

PF12

0L

A3h

⇒

.M

8Ch

PF13

0M

A4h

⇐

.N

8Dh

PF14

0N

A5h

⇑

.O

8Eh

PF15

0O

A6h

⇓

.P

8Fh

PF16

0P

A7h

CLEAR

.Q

90h

PF17

0Q

A8h

FIELD -

.R

91h

PF18

0R

A9h

DUP

.S

92h

PF19

0S

AAh

ESC

.T

93h

PF20

0T

ABh

LINE FEED

.U

94h

PF21

0U

ACh

RESET

.V

95h

PF22

0V

ADh

CTRL

.W

96h

PF23

0W

AEh

SPECIAL

.X

97h

PF24

0X

AFh

122

MB/NX/RM/00/E/970131

Page 133

RS-232 input devices UDI / CICS For special keyboard wedge applications, the MicroBar NX converts ASCII character FF (0Ch) to wedge character ENTER and ASCII character DC1 (11h) to wedge character TAB.

Not Active (*)

Active

MB/NX/RM/00/E/970131

123

Page 134

RS-232 - Output to host system

RS-232 - Output to host system Connection - RS-232 C, RS-232 TTL serial port host system

Ø • undecoded pen • low-power wand emulation device (< 50 mA) 5V power supply (modular plug)

2

5V power supply (jack)

3

1

4 input device

1. Switch off the host system. 2. Use the RS-232 cable to connect the MicroBar NX to the host system. 3. Connect your data input devices to the MicroBar NX. 4. Connect the external power supply (jack or modular plug) to the MicroBar NX. 5. Plug the power supply into the mains socket. 6. Switch on the host system.

M Do not switch on the host system until you have connected up and plugged in the external power supply.

124

MB/NX/RM/00/E/970131

Page 135

RS-232 - Output to host system Connection - Dual RS-232 C The default hardware configuration of the MicroBar NX transmits data on the DTE connector (to host) only.

serial port serial port

×

Ø host system terminal terminal

Ï DCE

DTE

Ð host • undecoded pen • low-power wand emulation device (< 50 mA)

5V power supply (modular plug)

2

5V power supply (jack)

3

1

4 input device

1. Switch off the host system. 2. Disconnect the terminal from the host system. 3. Use the dual RS-232 cable to connect the MicroBar NX between the terminal and the host system. 4. Connect your data input devices to the MicroBar NX. 5. Connect the external power supply (jack or modular plug) to the MicroBar NX. 6. Plug the power supply into the mains socket. 7. Switch on the host system.

M Do not switch on the host system until you have connected up and plugged in the external power supply. MB/NX/RM/00/E/970131

125

Page 136

RS-232 - Output to host system Predefined interface numbers If your interface number is not among the predefined interface numbers, you must compose the number yourself (Ð Compose interface number ).

Predefined interface numbers - RS-232 N° 100 - Standard RS-232 C (9600, 7, E, 2)

N° 101 - RS-232 TTL Level

N° 102 - RS-232 PC Term

N° 105 - RS-232 Slave Mode

Ð RS-232 - Slave mode

126

MB/NX/RM/00/E/970131

Page 137

RS-232 - Output to host system Predefined data transmission settings Predefined settings for RS-232 - Interface N° 100 baud rate

-

9600 data bits

-

7 parity

- even stop bits

-

2 time-out (hardware and software)

-

1000 ms

ENQ (Hex 05)

- not used

ACK (Hex 06)

- not used

NAK (Hex 15)

- not used

XON/XOFF (software)

- inactive

RTS/CTS (hardware)

- inactive

RTS/CTS management

- low RTS idle

LRC (longitudinal redundancy check)

- inactive preamble

- none postamble

-

Carriage Return + Line Feed inter-character delay

- none inter-message delay

- none

In this section, the predefined parameter settings for interface N° 100 (Standard RS-232) are indicated by an asterisk (*).

MB/NX/RM/00/E/970131

127

Page 138

RS-232 - Output to host system Baud Rate 9600 (*)

75

150

300

600

1200

2400

4800

19200

38400

128

MB/NX/RM/00/E/970131

Page 139

RS-232 - Output to host system Data bits Seven (*)

Eight

Parity Even (*)

Odd

Mark

Space

None

Stop bits Two (*)

One

MB/NX/RM/00/E/970131

129

Page 140

RS-232 - Output to host system Hardware/software protocols timeout The same timeout value applies to all the RS-232 protocols supported by the MicroBar NX: •

ENQ / ACK / NAK software protocol,

•

XON / XOFF software protocol,

•

RTS / CTS hardware protocol.

1000 ms (*)

Unlimited Timeout (value = 0)

Compose timeout Compose Timeout (minimum = 1 ms, maximum = 2500 ms)

Example

To set a hardware and software timeout of 2 seconds (= 2000 ms): 1. Scan Compose Timeout. 2. Scan the desired value in milliseconds - in our example we would scan 2 0 0 0 (Ð Number codes or inside back cover of this manual). 3. Scan End Selection to finish.

130