Page 61

C

Magstripe parameters

This appendix provides some common parameter settings for magstripe input devices - use a barcode reader to read the corresponding configuration codes. Keep a list of your custom settings - this will be useful if you have to perform a reset. The full set of magstripe parameter options is provided in the MicroBar NX Reference Manual (Ð Magstripe input devices ). Factory default settings are indicated by an asterisk (*).

Track selection The MicroBar NX can read 1 track or 2 tracks from a possible total of 1, 2, or 3 tracks.

Read All Tracks (*)

Track 1 Or 3

Track 2

Tracks 1 And 2

Tracks 2 And 3

MB/NX/IG/00/E/961031

C-1

Page 62

C. Magstripe parameters Advanced parameters - MicroBar NX Reference Manual transmission sequence track separator character start/end sentinels LRC check digit -

C-2 track 1 / track 3 then track 2 (*) track 2 then track 1 / track 3 user-defined (default = #) not transmitted (*) transmitted checked but not transmitted (*) checked and transmitted

MB/NX/IG/00/E/961031

Page 63

D

RS-232 input device data transmission parameters

Use the configuration codes in this appendix to change the default RS-232 data transmission parameter settings if you have an RS-232 C or RS-232 TTL input device on Port 4 of the MicroBar NX. Keep a list of your custom settings - this will be useful if you have to perform a reset. The full set of parameter options for RS-232 input devices is provided in the MicroBar NX Reference Manual (Ð RS-232 input devices ). Factory default settings are indicated by an asterisk (*).

Baud Rate 9600 (*)

1200

2400

4800

MB/NX/IG/00/E/961031

D-1

Page 64

D. RS-232 input device data transmission parameters Data bits Seven (*)

Eight

Parity Even (*)

Odd

None

Stop bits One (*)

Two

D-2

MB/NX/IG/00/E/961031

Page 65

D. RS-232 input device data transmission parameters RTS/CTS hardware protocol When the RTS/CTS protocol is activated, the MicroBar NX waits for an RTS from the RS-232 input device and sends a CTS when it is ready to receive data.

Not Active (*)

Active

Transmission to the host system Transmit on end-of-message character The RS-232 input device transmits data on a message-by-message basis. By default, the MicroBar NX transfers the data to an input buffer (250 characters maximum) and sends the data to the host system when it receives an end-of-message character (Carriage Return (0Dh) by default).

Transmit On End-Of-Message Character (*)

Carriage Return (*)

Carriage Return + Line Feed

MB/NX/IG/00/E/961031

D-3

Page 66

D. RS-232 input device data transmission parameters Transmit character by character Transmit Character By Character transmits to the host system each character as it is received - the characters do not go through the input buffer. If you use this option, we recommend that you activate the RTS/CTS protocol with the input device. Transmit Character By Character

Transmit on timeout Transmit On Timeout transmits the buffered message to the host system when the specified timeout value is received - useful if the RS-232 input device does not send an end-ofmessage character for example. Transmit On Timeout Not Active (*)

Transmit On Timeout (default = 2.5 s)

ASCII control code transmission filter The RS-232 input device may send control characters that you do not want the MicroBar NX to transmit to the host system - preambles and end-of-message characters for example. With the ASCII control code transmission filter, ASCII control characters 00h-20h received from the RS-232 input device are removed by the MicroBar NX before the data is transmitted to the host system. Transmit All ASCII Characters (*)

Do Not Transmit ASCII Characters 00h-20h

D-4

MB/NX/IG/00/E/961031

Page 67

D. RS-232 input device data transmission parameters Advanced parameters - MicroBar NX Reference Manual baud rate parity ENQ / ACK / NAK software protocol XON/XOFF software protocol transmit on end-of-message character transmit on timeout -

300 600 mark space ENQ not active (*) ENQ (HEX 05) ACK not active ACK (HEX 06) (*) NAK not active NAK (HEX 15) (*) not active (*) active user-defined end-of-message character user-defined timeout

Special keys interpretation - Output to keyboard wedge dual-character combinations - not active (*) - always active - only active if separate 2-character label or if preceded by a hyphen ( - ) - only active if separate 2-character label single character with ASCII value > 7Fh - only active if separate 8-bit character label UDI / CICS - not active (*) - active

MB/NX/IG/00/E/961031

D-5

Page 68

D. RS-232 input device data transmission parameters

D-6

MB/NX/IG/00/E/961031

Page 69

E

Additional operating parameters

This appendix provides a list of additional operating parameters not provided in this Installation Guide. The full set of MicroBar NX operating parameter options is provided in the MicroBar NX Reference Manual. Factory default settings are indicated by an asterisk (*).

Configuration modes copy configuration mode - source / target selection configuration password mode - not active - user-defined password temporary configuration mode - enable - restore current configuration - update current configuration display data string mode - enable

Beeps good read beeps - 1beep (*) - 2 beeps - no beep timing of good read beeps - before transmission (*) - after transmission duration of good read beeps - 80 ms (*) - 60 ms - 200 ms - 300 ms - user-defined (0 to 999 ms)

Input identifiers position - before barcode data - after barcode data - port 1 / 3 - port 4 - port 5

MB/NX/IG/00/E/961031

E-1

Page 70

E. Additional operating parameters Data decoding security parameters consecutive same read data validation - single read before transmission (*) - user-defined number of consecutive same reads before transmission (maximum = 10)

Data formatting - activation - I/O port selection - symbology selection - define input data length - define reformatting sequence - insert addiitonal characters - insert delays - substitute / delete characters

E-2