Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 8

MicroBar NX Installation Guide, pages 51 to 60

Pages 51 to 60 of 78

The original document is the PDF (362 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the UBI NX

Page 51

A. Symbology parameters for barcode readers Standard 2 of 5 Standard 2 of 5 is also referred to as "Straight 2 of 5" and "Industrial 2 of 5".

Activation Not Active (*)

Active (default format = Identicon)

MB/NX/IG/00/E/961031

A-17

Page 52

A. Symbology parameters for barcode readers Standard 2 of 5 Common parameter settings - Barcode length Barcode length (number of characters) for Standard 2 of 5 = [barcode data + check digit if applicable]. The minimum length possible is 3 characters. For maximum security, we strongly recommend that you define 1, 2 or 3 fixed lengths.

M The Any Length code provides zero security. Any Length (*)

Define 1 Or 2 Or 3 Fixed Lengths - Use Number Codes

Define 1 Or 2 Or 3 Fixed Lengths - Use Actual Code Lengths

Defining 1 or 2 or 3 fixed lengths using the number codes 1. Scan Define 1 Or 2 Or 3 Fixed Lengths - Use Number Codes. 2. Use the number codes provided on the back cover of this Installation Guide to enter 1, 2 or 3 lengths and scan End Selection after each length. If you only enter 1 or 2 fixed lengths, scan End Selection twice after the last length you enter (after the first or second length as applicable). Defining 1 or 2 or 3 fixed lengths using actual code lengths 1. Scan Define 1 Or 2 Or 3 Fixed Lengths - Use Actual Code Lengths. 2. Scan the number code - 1 or 2 or 3 - corresponding to the number of lengths you want to define using the number codes provided on the back cover of this Installation Guide. 3. Scan End Selection. The first / second / third Standard 2 of 5 codes with different lengths that you read will fix the accepted code lengths - the MicroBar NX will then not accept codes with other lengths.

A-18

MB/NX/IG/00/E/961031

Page 53

A. Symbology parameters for barcode readers Standard 2 of 5 Advanced parameters - MicroBar NX Reference Manual start/stop bars check digit mod 10 -

MB/NX/IG/00/E/961031

Identicon (6 Bars) (*) Computer Identics (4 Bars) not used (*) checked and transmitted checked but not transmitted

A-19

Page 54

A. Symbology parameters for barcode readers Telepen Activation Not Active (*)

Active

Format ASCII (*)

Numeric

A-20

MB/NX/IG/00/E/961031

Page 55

A. Symbology parameters for barcode readers UPC/EAN code families (UPC-A, UPC-E, EAN-8, EAN-13) (*) Activation Active - All UPC/EAN (*)

Not Active - All UPC/EAN

UPC-A Transmitted as EAN-13 (*)

UPC-A Transmitted as UPC-A

Add-On Digits Not Required But Transmitted If Read (*)

Add-On Required And Transmitted

Add-On 2 Not Active (*)

Add-On 2 Active

Add-On 5 Not Active (*)

Add-On 5 Active

MB/NX/IG/00/E/961031

A-21

Page 56

A. Symbology parameters for barcode readers UPC/EAN code families (UPC-A, UPC-E, EAN-8, EAN-13) (*) Common parameter settings - Check digit UPC/EAN code format: <leading character> <number system> <data> <check digit> UPC-A Check Digit - Transmitted (*)

UPC-A Check Digit - Not Transmitted

UPC-E Check Digit - Transmitted (*)

UPC-E Check Digit - Not Transmitted

EAN-8 Check Digit - Transmitted (*)

EAN-8 Check Digit - Not Transmitted

EAN-13 Check Digit - Transmitted (*)

EAN-13 Check Digit - Not Transmitted

A-22

MB/NX/IG/00/E/961031

Page 57

A. Symbology parameters for barcode readers UPC/EAN code families (UPC-A, UPC-E, EAN-8, EAN-13) (*) Common parameter settings - Transmission of number system UPC/EAN code format: <leading character> <number system> <data> <check digit> A regular UPC-A has a transmitted number system equal to 0. To transmit the additional leading character (country code), select the parameter UPC-A Transmitted As EAN-13.

UPC-A Number System - Transmitted (*)

UPC-A Number System - Not Transmitted

UPC-E Number System - Transmitted (*)

UPC-E Number System - Not Transmitted

Advanced parameters - MicroBar NX Reference Manual UPC/EAN format deactivation re-encoding UPC-E, EAN-8 -

MB/NX/IG/00/E/961031 all active - UPC-A, UPC-E, EAN-8, EAN-13 (*) UPC-A deactivated UPC-E deactivated EAN-8 deactivated EAN-13 deactivated UPC-E transmitted as UPC-E (*) UPC-E transmitted as UPC-A EAN-8 transmitted as EAN 8 (*) EAN-8 transmitted as EAN-13

A-23

Page 58

A. Symbology parameters for barcode readers

A-24

MB/NX/IG/00/E/961031

Page 59

B

Laser scanner parameters

This appendix provides some common parameter settings for laser scanner input devices. Keep a list of your custom settings - this will be useful if you have to perform a reset. The full set of laser scanner parameter options is provided in the MicroBar NX Reference Manual (Ð Laser scanner input devices ). Factory default settings are indicated by an asterisk (*).

Laser timeout before deactivation Laser scanners normally remain active until the trigger is released or a timeout period is reached. The laser timeout codes allow the MicroBar NX to control the timeout period before deactivation and are valid for all laser trigger configurations.

2 sec (*)

1 sec

3 sec

8 sec

MB/NX/IG/00/E/961031

B-1

Page 60

B. Laser scanner parameters Marker beam The marker beam is a spot of light to make aiming easier. Marker Beam On activates the laser scanner marker beam when the trigger is pressed. Marker beam is only available for UBI ScanImage 9x0 and QuickScan laser scanners equipped with a special cable.

Marker Beam Off (*)

Marker Beam On

Advanced parameters - MicroBar NX Reference Manual RS-232 trigger CTS trigger autostand mode “code not read” message -

B-2 not active (*) user-defined activation character not active (*) low level active high level active autostand off (*) autostand on not active (*) user-defined ASCII character and repetition number (max = 20)

MB/NX/IG/00/E/961031