Page 551
CHAPTER
20 20
Laser Observations In this chapter: ■
Introduction
■
Configuring the Trimble Survey Controller software
■
Configuring the laser
■
Connecting the laser to the TSC1 data collector
■
Taking a measurement with the laser rangefinder
■
Laser softkey
Page 552
20
Laser Observations
20.1
Introduction If a point cannot be occupied directly by a GPS rover, one way to measure it is to use a laser rangefinder with the Trimble Survey Controller software. This combination of laser rangefinder and Trimble Survey Controller software can also be used with a conventional instrument. Alternatively, the laser rangefinder can be plugged into the TSC1 data collector and used standalone with the Trimble Survey Controller software. The Trimble Survey Controller software supports the following laser rangefinders: •
Laser Technology Criterion 300
•
Laser Technology Criterion 400
•
Laser Technology Impulse
•
Laser Atlanta Advantage CI
•
Leica Disto memo
•
Leica Disto pro
•
MDL LaserAce 300
•
MDL Generation II Surveyor
Note – Contact your local Trimble dealer for a current list of lasers that the Trimble Survey Controller software supports.
20.2
Configuring the Trimble Survey Controller software To use a laser rangefinder with the Trimble Survey Controller software, first configure a Survey Style appropriately. A laser rangefinder can be used with any Survey Style.
E
To configure the Survey Style:
52 0
1.
From the main menu, choose Survey. Highlight a Survey Style . and press
2.
Select Laser rangefinder and press
Trimble Survey Controller Reference Manual Volume 2
\
.
Page 553
Laser Observations
3.
4.
20
Set the Type field to one of the following: –
LTI Criterion 300
–
LTI Criterion 400
–
LTI Impulse
–
Laser Atlanta Advantage
–
Leica Disto memo/pro
–
MDL LaserAce 300
–
MDL Generation II
Set the Controller port and Baud rate fields if required. The default value in the Baud rate field is the manufacturer’s recommended setting.
m
If the Trimble Survey Controller software can automatically , instruct the laser to take a measurement when you press you can edit the Auto measure field as required. 5.
Set the Auto store point field as required. The precision fields contain the manufacturer’s precision values for the laser. They are for information only.
6.
20.2.1
Press
\
.
Magnetic Declination Most lasers have a magnetic compass. Make sure that this compass is calibrated before making any measurements. When a value for magnetic declination is entered in the Trimble Survey Controller software, it is applied to all subsequent laser measurements. To enter a value for magnetic declination: 1.
Select Configuration / Job / Cogo settings.
2.
Enter a value in the Magnetic declination field. Trimble Survey Controller Reference Manual Volume 2
521
Page 554
20
Laser Observations
For more information about magnetic declination, see Magnetic Declination, page 109.
C 20.2.2
Warning – If you enter a value for magnetic declination in the Trimble Survey Controller software, make sure that no magnetic declination value is set in the laser.
Vertical Angle Display To configure how the laser measurements are displayed - as vertical angles measured from the zenith or inclinations measured from horizontal - set the Laser VA display field in the Units screen. For more information, see System Units, page 101
20.3
Configuring the Laser Before using the laser with the TSC1 data collector, set various options on the laser. Table 20.1 shows the settings for each laser supported by the Trimble Survey Controller software. Table 20.1
52 2
Laser settings
Laser
Laser setting
LTI Criterion 300 or LTI Criterion 400
From the main menu, press the down arrow or up arrow key until the Survey menu appears, then press ENTER. Select Basic measurements and press ENTER. A screen showing the fields HD and AZ appears.
LTI Impulse
Set up the laser to operate in CR 400D format. Make sure that a small ‘D’ is displayed on the screen. (If necessary, press the Fire2 button on the laser).
Laser Atlanta Advantage
Set the Range/Mode option to Standard (Averaged) and the Serial/Format option to Trimble Pro XL.
Leica Disto memo/pro
Set the unit to meters or feet, not feet and inches.
Trimble Survey Controller Reference Manual Volume 2
Page 555
Laser Observations Table 20.1
20
Laser settings (Continued)
Laser
Laser setting
MDL Generation II
No special settings are required.
MDL LaserAce
Set the Data record format to Mode 1. When using the angle encoder, set the magnetic declination to zero in the Trimble Survey Controller. The angle encoder in the LaserAce corrects for the magnetic declination.
Note – The laser rangefinder must be configured to update the inclinometer and slope distance readings after each measurement.
20.4
Connecting the Laser to the TSC1 Data Collector Use the null modem 0-shell Lemo to DB9 cable (part number 37779) to connect the TSC1 data collector to the DB9 connector from the laser. Connect it to the port you specified in the Survey Style. Note – For a conventional survey with the instrument type set to Manual, connect the laser to the top port of the TSC1 data collector.
20.5
Taking a Measurement with the Laser Rangefinder To measure a point with the laser rangefinder: 1.
Configure the Survey Style that you intend to use. Note – If Measure laser points does not appear in the Survey menu, the Laser rangefinder type field in the Survey Style is set to None. Change it to the laser type you are using.
2.
Connect the laser to the TSC1 data collector as described in Connecting the Laser to the TSC1 Data Collector, page 523.
3.
Make sure that the laser is set up to take azimuth and distance measurements, and inclination (the last is optional).
Trimble Survey Controller Reference Manual Volume 2
523
Page 556
20
Laser Observations
\
4.
On the TSC1, from the main menu, choose Survey. Highlight the Survey Style that you intend to use and press .
5.
Select Measure laser points.
6.
Enter a value in the Point name field.
7.
Enter a value in the Code field if required.
8.
In the Start point field, enter the name of the point that laser measurements are to be taken from.
9.
Enter a value in the Laser height field if required.
m
10. Enter a value in the Target height field if required. 11. Occupy the start point with the laser and press instructions on the TSC1 display screen.
Wait for the laser compass to settle before taking a measurement.
B m
. Follow the m
If the Auto measure field in the Survey Style Laser Rangefinder option is set to Yes, the Trimble Survey Controller software . instructs the laser to take a measurement when you press The Trimble Survey Controller software displays this measurement when it is receives it.
Tip – It is possible to take a measurement on the laser without pressing first. The laser measurement is displayed on the screen of the TSC1 data collector when the data is received.
If the Trimble Survey Controller software receives only a distance measurement from the laser, another screen is displayed with the measured distance in a Slope distance field. Enter a vertical angle if the measured distance was not horizontal. 12. Press s to store the point.
Note – If using a laser without a compass, you must key in a magnetic azimuth before the Trimble Survey Controller software can store the point. 52 4
Trimble Survey Controller Reference Manual Volume 2
Page 557
Laser Observations
20.6
20
M
Laser Softkey
In most H. Dist (horizontal distance) fields and S. Dist (slope distance) fields in the Trimble Survey Controller software, there is a softkey. Use it to measure a distance with the laser and insert that value in the H.Dist field. This function is useful when calculating an offset or intersection point. To use the laser in a H.Dist field:
(
M
1.
Configure the laser in the Survey Style that you intend to use.
2.
To access the H.Dist field, press . Press instructions on the TSC1 screen.
3.
When the Trimble Survey Controller software receives the measurement, it inserts the horizontal distance into the H.Dist field.
and follow the
Trimble Survey Controller Reference Manual Volume 2
525
Page 558
20
Laser Observations
52 6
Trimble Survey Controller Reference Manual Volume 2