Page 395

CHAPTER

15 15

Point Measurement Methods In this chapter: ■

Introduction

■

Default point name

■

Point name incrementation

■

Next free point name search

■

Survey/measure points screen in a gps survey

■

Survey/measure points screen in a conventional survey

■

Measuring a topo point in a GPS survey

■

Measuring a FastStatic point

■

Measuring an observed control point

■

Measuring a rapid point

■

Measuring continuous topo points

■

Measuring an as-staked point

■

Measuring a laser point

■

Measuring a calibration point

■

Measuring a check point

■

Point storage in the Trimble Survey Controller software

■

Quality control records

Page 396

15

15.1

Point Measurement Methods

Introduction In a conventional survey, the only type of points that you can measure are topo points or check points. In a GPS survey, you measure points by choosing one of several predefined point types. In a GPS survey, the Survey Style (and so the survey type) you choose determines the type of point(s) that can be measured. A single Survey Style cannot measure every kind of point, so it is necessary to use different Survey Styles to measure different kinds of point. An RTK Survey Style, for example, can be used to measure observed control points, Rapid points, topo points, and calibration points, but to measure a FastStatic point, you must use a FastStatic Survey Style. For more information, see Chapter 7, Survey Styles. This chapter shows how to change some survey settings. It shows how to measure different types of point, and explains the quality control records that are stored when a point is measured using GPS. Note – For RTK surveys, initialize the survey before measuring points.

15.2

Default Point Name When you start a new survey, the Trimble Survey Controller software inserts a default value in the Point name field for a topo point, Rapid point, and continuous point. This default point name is the next available point name in the current job. If no points of that type have been measured in the current job, the Trimble Survey Controller software searches the last job and inserts the next available point name. It does this so that you can download several jobs into one Trimble Geomatics Office or Trimble Survey Office project. If you do not want to use the default point name that appears, change the value in the Point name field. This value increments once a point is measured.

36 4

Trimble Survey Controller Reference Manual Volume 2

Page 397

Point Measurement Methods

15.3

15

Point Name Incrementation When measuring topo points, Rapid points, or continuous points, the Trimble Survey Controller software automatically increments the value in the Point name field. For topo points, it is possible to change the value of this increment. To do this, select Topo point from the option menu for the chosen Survey Style. Set the Auto point step size field to the value the name should increment by each time a point is measured. A negative value decreases the value in the Point name field.

15.4 f

Next Free Point Name Search In Point name fields there is a for the next available point name.

softkey that allows you to search

For example, if your job contains points numbered in the 1000’s, 2000’s and 3000’s, and you want to find the next available point name after 1000:

f O

. The Find next free point

1.

In the Point name field, press name screen appears.

2.

Enter the point name you want to start searching from (in this . example, 1000) and press

3.

The Trimble Survey Controller software searches for the next available point name after 1000 and inserts it in the Point name field.

Trimble Survey Controller Reference Manual Volume 2

365

Page 398

15

15.5

Point Measurement Methods

Survey/Measure Points Screen in a GPS Survey From the main menu, choose Survey. Select a GPS Survey Style, then select Measure points. The Survey/Measure points screen appears, as shown in Figure 15.1.

Figure 15.1

Survey/Measure points screen

Enter a point name and change the Type field to the type of point to be measured. (For more information about each type of point that can be measured, see the following sections.) Enter a value in the Antenna height field and check the setting in the Meas. to field.

o

. It is not To change some settings for the current survey, press possible to change the current Survey Style or the system settings. Note – You can view points that you have measured in the current job graphically in the current job map. For more information, see Map of Current Job, page 95.

15.6

Survey/Measure Points Screen in a Conventional Survey Please see Measuring Points, page 482.

36 6

Trimble Survey Controller Reference Manual Volume 2

Page 399

Point Measurement Methods

15.7

15

Measuring a Topo Point in a GPS Survey You can measure a topo point in every type of survey except a FastStatic survey. To measure a topo point: 1.

From the main menu, select Survey / Measure points.

2.

Enter values in the Point name and Code fields (the latter is optional) and change the Type field to Topo point.

3.

Enter a value in the Antenna height field and make sure that the setting in the Meas to. field is correct.

4.

When the antenna is vertical and stationary, press to start recording data.

s

\m or

The static icon appears in the status line. 5.

B 15.8 softkey appears when the preset occupation time and The precisions have been reached. Press it to store the point.

Tip – In the Survey Style, set the Auto store point field to Yes to automatically store the point when the preset occupation time and precisions have been met.

Measuring a FastStatic Point You can only measure a FastStatic point in a FastStatic survey. Note – FastStatic surveys are postprocessed and do not need to be initialized. To measure a FastStatic point: 1.

From the main menu, select Survey / Measure points.

2.

Enter values in the Point name and Code fields (the latter is optional).

Trimble Survey Controller Reference Manual Volume 2

367

Page 400

15

Point Measurement Methods

\m

3.

Enter a value in the Antenna height field and make sure that the setting in the Meas to. field is correct.

4.

Press

5.

softkey appears when the preset occupation time is The reached (see Table 15.1). Press it to store the point.

s or to start measuring the point.

Table 15.1 shows the occupation times for FastStatic surveys. Table 15.1

B 15.9

Trimble FastStatic occupation times

Receiver type

4 SVs

5 SVs

6+ SVs

Single-frequency

30 min

25 min

20 min

Dual-frequency

20 min

15 min

8 min

Tip – No satellite tracking is necessary between measuring points. You can turn off the equipment.

Measuring an Observed Control Point When the Trimble Survey Controller software measures an observed control point, it stores a point when the preset number of epochs has elapsed and the precisions have been attained. To measure a observed control point:

36 8

1.

From the main menu, select Survey / Measure points.

2.

Enter values in the Point name and Code fields (the latter is optional), and change the Type field to Observed control point.

3.

Enter a value in the Antenna height field and make sure that the setting in the Meas to. field is correct.

4.

Press

5.

The softkey appears when the preset number of epochs and precisions are reached. Press it to store the point.

\m s or to start recording data.

Trimble Survey Controller Reference Manual Volume 2

Page 401

Point Measurement Methods

15

Note – For an RTK survey, initialize the survey before starting to measure the point. For a postprocessed kinematic survey, you can start measuring before the survey is initialized but you cannot store the point until it is initialized.

Measuring a Rapid Point

15.10

A Rapid point is stored when the preset precisions are attained. There is no minimum occupation time and point storage is automatic. To measure a Rapid point: 1.

From the main menu, select Survey / Measure points.

2.

Enter values in the Point name and Code fields (the latter is optional), and change the Type field to Rapid point.

3.

Enter a value in the Antenna height field and make sure that the setting in the Meas to. field is correct.

4.

or to start recording data. The point is Press automatically stored when the preset precisions are reached.

\m

Note – When using WAAS positions in a survey, the only type of point you can store is a Rapid point.

15.11

Measuring Continuous Topo Points Continuous topo points are stored automatically and continuously after a preset time and/or distance once the required precisions are reached. In a real-time survey, the Trimble Survey Controller software can measure a line of continuous offset points at the same time as a line of continuous topo points.

Trimble Survey Controller Reference Manual Volume 2

369

Page 402

15 15.11.1

Point Measurement Methods

Measuring a Line of Continuous Points To measure a line of continuous topo points: 1.

From the main menu, select Survey / Continuous topo.

2.

Set the Type field to Fixed distance continuous, Fixed time continuous, or Time & distance continuous. Note – For a postprocessed survey, you can only use the Fixed time continuous method. The time interval is set to the same value as the logging interval.

3.

Enter a value in the Antenna height field and make sure that the setting in the Meas to. field is correct.

4.

Enter a value in the Horizontal distance field and/or the Time interval field, depending on the method you are using.

5.

If measuring Fixed distance or Time & distance continuous points, set the Offset field to None.

6.

Enter a value in the Start point name field. This increments automatically.

7.

to start recording data, and then move along the Press feature to be surveyed.

m

There is an audible beep every time a point is recorded.

e

Note – To change the distance interval, time interval, or offset while measuring points, enter new values in the fields. 8.

15.11.2

To stop measuring continuous points, press

.

Measuring a Line of Continuous Offset Points To measure a line of continuous offset points:

37 0

1.

From the main menu, select Survey / Continuous topo.

2.

Set the Type field to Fixed distance continuous or Time & distance continuous.

Trimble Survey Controller Reference Manual Volume 2

Page 403

Point Measurement Methods

15

3.

Enter a value in the Antenna height field and make sure that the setting in the Meas to. field is correct.

4.

If the Type field is set to Time & distance continuous, enter a value in the Time interval field.

5.

Enter the interval in the Horizontal distance field, and change the setting in the Offset field to None, One, or Two.

6.

Enter a value for the center line in the Start point name field. This increments automatically.

7.

Enter the horizontal offset distance for Offset one (the first line of offset points).

Ô Õ

Note – Enter a left or a right offset. For a left offset, enter a and softkeys. negative offset distance or use the 8.

Enter the vertical offset distance for Offset one.

9.

Enter a value in the Start point name field for Offset one. This increments automatically.

m

10. If measuring two offset lines, repeat Steps 5 through 9 for Offset two. to start recording data, and then move along the 11. Press feature to be surveyed.

e

There is an audible beep every time a point is recorded. 12. To stop measuring continuous offset points, press

.

Calculating continuous offset points The Trimble Survey Controller software calculates continuous offset points. When three continuous points have been measured, the half-angle is calculated between the two lines described by the three points. The offset point is then placed at a distance computed from the offset value and the half-angle.

Trimble Survey Controller Reference Manual Volume 2

371

Page 404

15

Point Measurement Methods

For the first continuous point, the offset point is placed at right angles to the line to the next continuous point. For the last continuous point, it is placed at right angles to the line to the previous continuous point. These calculations ensure that the offset line stays parallel to the continuous line of points. Figure 15.2 shows how continuous offset points are calculated.

Direction of survey Measured point Offset point Offset distance (right)

Figure 15.2

Calculation of continuous offset points

The line between offset points is parallel to the lines between the continuous points and is offset by the value specified.

37 2

Trimble Survey Controller Reference Manual Volume 2